Ultrastructure of clear corneal incisions. Part II: Corneal trauma after lens implantation with the Microstaar injector system.

Identifieur interne : 001F68 ( PubMed/Curation ); précédent : 001F67; suivant : 001F69

Ultrastructure of clear corneal incisions. Part II: Corneal trauma after lens implantation with the Microstaar injector system.

Auteurs : W. Radner [Autriche] ; R. Menapace ; M. Zehetmayer ; C. Mudrich ; R. Mallinger

Source :

RBID : pubmed:9584244

English descriptors

Abstract

To examine the ultrastructure of clear corneal incisions (CCIs) after implantation of a plate-hepatic intraocular lens (IOL) with the Microstaar injector system through two incision widths.

PubMed: 9584244

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:9584244

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Ultrastructure of clear corneal incisions. Part II: Corneal trauma after lens implantation with the Microstaar injector system.</title>
<author>
<name sortKey="Radner, W" sort="Radner, W" uniqKey="Radner W" first="W" last="Radner">W. Radner</name>
<affiliation wicri:level="1">
<nlm:affiliation>University Eye Clinic, Vienna, Austria.</nlm:affiliation>
<country xml:lang="fr">Autriche</country>
<wicri:regionArea>University Eye Clinic, Vienna</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Menapace, R" sort="Menapace, R" uniqKey="Menapace R" first="R" last="Menapace">R. Menapace</name>
</author>
<author>
<name sortKey="Zehetmayer, M" sort="Zehetmayer, M" uniqKey="Zehetmayer M" first="M" last="Zehetmayer">M. Zehetmayer</name>
</author>
<author>
<name sortKey="Mudrich, C" sort="Mudrich, C" uniqKey="Mudrich C" first="C" last="Mudrich">C. Mudrich</name>
</author>
<author>
<name sortKey="Mallinger, R" sort="Mallinger, R" uniqKey="Mallinger R" first="R" last="Mallinger">R. Mallinger</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1998">1998</date>
<idno type="RBID">pubmed:9584244</idno>
<idno type="pmid">9584244</idno>
<idno type="wicri:Area/PubMed/Corpus">001F68</idno>
<idno type="wicri:Area/PubMed/Curation">001F68</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Ultrastructure of clear corneal incisions. Part II: Corneal trauma after lens implantation with the Microstaar injector system.</title>
<author>
<name sortKey="Radner, W" sort="Radner, W" uniqKey="Radner W" first="W" last="Radner">W. Radner</name>
<affiliation wicri:level="1">
<nlm:affiliation>University Eye Clinic, Vienna, Austria.</nlm:affiliation>
<country xml:lang="fr">Autriche</country>
<wicri:regionArea>University Eye Clinic, Vienna</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Menapace, R" sort="Menapace, R" uniqKey="Menapace R" first="R" last="Menapace">R. Menapace</name>
</author>
<author>
<name sortKey="Zehetmayer, M" sort="Zehetmayer, M" uniqKey="Zehetmayer M" first="M" last="Zehetmayer">M. Zehetmayer</name>
</author>
<author>
<name sortKey="Mudrich, C" sort="Mudrich, C" uniqKey="Mudrich C" first="C" last="Mudrich">C. Mudrich</name>
</author>
<author>
<name sortKey="Mallinger, R" sort="Mallinger, R" uniqKey="Mallinger R" first="R" last="Mallinger">R. Mallinger</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="1998" type="published">1998</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Cadaver</term>
<term>Cataract Extraction (methods)</term>
<term>Collagen (ultrastructure)</term>
<term>Cornea (surgery)</term>
<term>Cornea (ultrastructure)</term>
<term>Corneal Injuries</term>
<term>Eye Injuries, Penetrating (etiology)</term>
<term>Eye Injuries, Penetrating (pathology)</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (adverse effects)</term>
<term>Lens Implantation, Intraocular (instrumentation)</term>
<term>Microscopy, Electron, Scanning</term>
<term>Middle Aged</term>
<term>Ophthalmology (instrumentation)</term>
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="ultrastructure" xml:lang="en">
<term>Collagen</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Eye Injuries, Penetrating</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
<term>Ophthalmology</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Cataract Extraction</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Eye Injuries, Penetrating</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Cornea</term>
</keywords>
<keywords scheme="MESH" qualifier="ultrastructure" xml:lang="en">
<term>Cornea</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Cadaver</term>
<term>Corneal Injuries</term>
<term>Humans</term>
<term>Microscopy, Electron, Scanning</term>
<term>Middle Aged</term>
<term>Silicone Elastomers</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To examine the ultrastructure of clear corneal incisions (CCIs) after implantation of a plate-hepatic intraocular lens (IOL) with the Microstaar injector system through two incision widths.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">9584244</PMID>
<DateCreated>
<Year>1998</Year>
<Month>06</Month>
<Day>12</Day>
</DateCreated>
<DateCompleted>
<Year>1998</Year>
<Month>06</Month>
<Day>12</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>11</Month>
<Day>20</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>24</Volume>
<Issue>4</Issue>
<PubDate>
<Year>1998</Year>
<Month>Apr</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Ultrastructure of clear corneal incisions. Part II: Corneal trauma after lens implantation with the Microstaar injector system.</ArticleTitle>
<Pagination>
<MedlinePgn>493-7</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To examine the ultrastructure of clear corneal incisions (CCIs) after implantation of a plate-hepatic intraocular lens (IOL) with the Microstaar injector system through two incision widths.</AbstractText>
<AbstractText Label="SETTING" NlmCategory="METHODS">University Eye Clinic and Institute of Histology and Embryology II, University of Vienna, Austria.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Fourteen human cadaver eyes without prior ocular surgery were obtained from the University Eye Bank, Vienna. Single-plane CCIs were performed with 3.0 and 3.2 mm steel keratomes. Using the Microstaar injector system, a foldable silicone plate-haptic IOL (23 diopters) was implanted in the anterior chamber. During the entire procedure, the eye pressure was kept between 26 and 30 mm Hg by infusing balanced salt solution into the anterior chamber. Specimens for light microscopy and scanning electron microscopy were prepared according to standard procedures.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">After IOL implantation, the 3.0 mm steel blade incisions exhibited distinct distensions at their lateral ends. Adjacent to these distensions, the collagen lamellae were pressed apart, displaced, and torn. In 3.2 mm tunnels, the corneal trauma at both lateral ends was considerably less severe. These incisions also showed a better primary adaptation of the wound lips after implantations.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Implantation performed with the Microstaar injector system through 3.0 mm steel blade CCIs led to considerably more severe corneal trauma than implantation through 3.2 mm incisions.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Radner</LastName>
<ForeName>W</ForeName>
<Initials>W</Initials>
<AffiliationInfo>
<Affiliation>University Eye Clinic, Vienna, Austria.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Menapace</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Zehetmayer</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Mudrich</LastName>
<ForeName>C</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Mallinger</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012826">Silicone Elastomers</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>9007-34-5</RegistryNumber>
<NameOfSubstance UI="D003094">Collagen</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002102">Cadaver</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002387">Cataract Extraction</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003094">Collagen</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000648">ultrastructure</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003315">Cornea</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000648">ultrastructure</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D065306">Corneal Injuries</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D015807">Eye Injuries, Penetrating</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000209">etiology</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000009">adverse effects</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008855">Microscopy, Electron, Scanning</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009885">Ophthalmology</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012826">Silicone Elastomers</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1998</Year>
<Month>5</Month>
<Day>19</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1998</Year>
<Month>5</Month>
<Day>19</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1998</Year>
<Month>5</Month>
<Day>19</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">9584244</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001F68 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 001F68 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:9584244
   |texte=   Ultrastructure of clear corneal incisions. Part II: Corneal trauma after lens implantation with the Microstaar injector system.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:9584244" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024