Complications arising from iris-fixated posterior chamber intraocular lenses.

Auteurs : Terry L. Kaiura [États-Unis] ; John A. Seedor ; Richard S. Koplin ; Michelle K. Rhee ; David C. Ritterband

Source :

RBID : pubmed:16473240

English descriptors

Abstract

Iris fixation of posterior chamber intraocular lenses (IOLs) is a technique that has been recommended for patients in whom a posterior chamber IOL is indicated but there is insufficient capsular support. We present 4 cases of iris-fixated posterior chamber IOLs with complications related to the procedure. Three patients developed postoperative slippage of the IOL, and 1 patient presented with iris erosion of the haptic leading to recurrent hemorrhage. Three cases were repaired by resuturing the same IOL using iris fixation, and in the last case IOL exchange with transscleral fixation of a posterior chamber IOL was performed. Final follow-up revealed stable IOLs in all cases.

DOI: 10.1016/j.jcrs.2005.06.048
PubMed: 16473240

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:16473240

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Complications arising from iris-fixated posterior chamber intraocular lenses.</title>
<author>
<name sortKey="Kaiura, Terry L" sort="Kaiura, Terry L" uniqKey="Kaiura T" first="Terry L" last="Kaiura">Terry L. Kaiura</name>
<affiliation wicri:level="1">
<nlm:affiliation>New York Eye and Ear Infirmary, New York, New York, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>New York Eye and Ear Infirmary, New York, New York</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Seedor, John A" sort="Seedor, John A" uniqKey="Seedor J" first="John A" last="Seedor">John A. Seedor</name>
</author>
<author>
<name sortKey="Koplin, Richard S" sort="Koplin, Richard S" uniqKey="Koplin R" first="Richard S" last="Koplin">Richard S. Koplin</name>
</author>
<author>
<name sortKey="Rhee, Michelle K" sort="Rhee, Michelle K" uniqKey="Rhee M" first="Michelle K" last="Rhee">Michelle K. Rhee</name>
</author>
<author>
<name sortKey="Ritterband, David C" sort="Ritterband, David C" uniqKey="Ritterband D" first="David C" last="Ritterband">David C. Ritterband</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2005">2005</date>
<idno type="doi">10.1016/j.jcrs.2005.06.048</idno>
<idno type="RBID">pubmed:16473240</idno>
<idno type="pmid">16473240</idno>
<idno type="wicri:Area/PubMed/Corpus">001833</idno>
<idno type="wicri:Area/PubMed/Curation">001833</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Complications arising from iris-fixated posterior chamber intraocular lenses.</title>
<author>
<name sortKey="Kaiura, Terry L" sort="Kaiura, Terry L" uniqKey="Kaiura T" first="Terry L" last="Kaiura">Terry L. Kaiura</name>
<affiliation wicri:level="1">
<nlm:affiliation>New York Eye and Ear Infirmary, New York, New York, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>New York Eye and Ear Infirmary, New York, New York</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Seedor, John A" sort="Seedor, John A" uniqKey="Seedor J" first="John A" last="Seedor">John A. Seedor</name>
</author>
<author>
<name sortKey="Koplin, Richard S" sort="Koplin, Richard S" uniqKey="Koplin R" first="Richard S" last="Koplin">Richard S. Koplin</name>
</author>
<author>
<name sortKey="Rhee, Michelle K" sort="Rhee, Michelle K" uniqKey="Rhee M" first="Michelle K" last="Rhee">Michelle K. Rhee</name>
</author>
<author>
<name sortKey="Ritterband, David C" sort="Ritterband, David C" uniqKey="Ritterband D" first="David C" last="Ritterband">David C. Ritterband</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2005" type="published">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Device Removal</term>
<term>Female</term>
<term>Foreign-Body Migration (etiology)</term>
<term>Foreign-Body Migration (surgery)</term>
<term>Humans</term>
<term>Iris (surgery)</term>
<term>Lens Implantation, Intraocular (adverse effects)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Postoperative Complications</term>
<term>Reoperation</term>
<term>Suture Techniques</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Foreign-Body Migration</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Foreign-Body Migration</term>
<term>Iris</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Device Removal</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Postoperative Complications</term>
<term>Reoperation</term>
<term>Suture Techniques</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Iris fixation of posterior chamber intraocular lenses (IOLs) is a technique that has been recommended for patients in whom a posterior chamber IOL is indicated but there is insufficient capsular support. We present 4 cases of iris-fixated posterior chamber IOLs with complications related to the procedure. Three patients developed postoperative slippage of the IOL, and 1 patient presented with iris erosion of the haptic leading to recurrent hemorrhage. Three cases were repaired by resuturing the same IOL using iris fixation, and in the last case IOL exchange with transscleral fixation of a posterior chamber IOL was performed. Final follow-up revealed stable IOLs in all cases.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">16473240</PMID>
<DateCreated>
<Year>2006</Year>
<Month>02</Month>
<Day>13</Day>
</DateCreated>
<DateCompleted>
<Year>2006</Year>
<Month>05</Month>
<Day>04</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>10</Month>
<Day>10</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>31</Volume>
<Issue>12</Issue>
<PubDate>
<Year>2005</Year>
<Month>Dec</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Complications arising from iris-fixated posterior chamber intraocular lenses.</ArticleTitle>
<Pagination>
<MedlinePgn>2420-2</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Iris fixation of posterior chamber intraocular lenses (IOLs) is a technique that has been recommended for patients in whom a posterior chamber IOL is indicated but there is insufficient capsular support. We present 4 cases of iris-fixated posterior chamber IOLs with complications related to the procedure. Three patients developed postoperative slippage of the IOL, and 1 patient presented with iris erosion of the haptic leading to recurrent hemorrhage. Three cases were repaired by resuturing the same IOL using iris fixation, and in the last case IOL exchange with transscleral fixation of a posterior chamber IOL was performed. Final follow-up revealed stable IOLs in all cases.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Kaiura</LastName>
<ForeName>Terry L</ForeName>
<Initials>TL</Initials>
<AffiliationInfo>
<Affiliation>New York Eye and Ear Infirmary, New York, New York, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Seedor</LastName>
<ForeName>John A</ForeName>
<Initials>JA</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Koplin</LastName>
<ForeName>Richard S</ForeName>
<Initials>RS</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Rhee</LastName>
<ForeName>Michelle K</ForeName>
<Initials>MK</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ritterband</LastName>
<ForeName>David C</ForeName>
<Initials>DC</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<CommentsCorrectionsList>
<CommentsCorrections RefType="CommentIn">
<RefSource>J Cataract Refract Surg. 2006 Sep;32(9):1409</RefSource>
<PMID Version="1">16931242</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D020878">Device Removal</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005548">Foreign-Body Migration</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007498">Iris</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000009">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011183">Postoperative Complications</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012086">Reoperation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013536">Suture Techniques</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="accepted">
<Year>2005</Year>
<Month>6</Month>
<Day>23</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2006</Year>
<Month>2</Month>
<Day>14</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2006</Year>
<Month>5</Month>
<Day>5</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2006</Year>
<Month>2</Month>
<Day>14</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0886-3350(05)00804-7</ArticleId>
<ArticleId IdType="doi">10.1016/j.jcrs.2005.06.048</ArticleId>
<ArticleId IdType="pubmed">16473240</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001833 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 001833 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:16473240
   |texte=   Complications arising from iris-fixated posterior chamber intraocular lenses.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:16473240" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024