Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia.

Identifieur interne : 001627 ( PubMed/Curation ); précédent : 001626; suivant : 001628

Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia.

Auteurs : Robert E. Maclaren [Royaume-Uni] ; Mythili Natkunarajah ; Yasmin Riaz ; Rupert R A. Bourne ; Marie Restori ; Bruce D S. Allan

Source :

RBID : pubmed:17524766

English descriptors

Abstract

To audit intraocular lens (IOL) power predictions for cataract surgery in extreme hyperopia and to compare the accuracy across different biometry formulae and IOL types.

DOI: 10.1016/j.ajo.2007.02.043
PubMed: 17524766

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:17524766

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia.</title>
<author>
<name sortKey="Maclaren, Robert E" sort="Maclaren, Robert E" uniqKey="Maclaren R" first="Robert E" last="Maclaren">Robert E. Maclaren</name>
<affiliation wicri:level="1">
<nlm:affiliation>Moorfields Eye Hospital, City Road, London, United Kingdom. robert.maclaren@moorfields.nhs.uk</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Moorfields Eye Hospital, City Road, London</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Natkunarajah, Mythili" sort="Natkunarajah, Mythili" uniqKey="Natkunarajah M" first="Mythili" last="Natkunarajah">Mythili Natkunarajah</name>
</author>
<author>
<name sortKey="Riaz, Yasmin" sort="Riaz, Yasmin" uniqKey="Riaz Y" first="Yasmin" last="Riaz">Yasmin Riaz</name>
</author>
<author>
<name sortKey="Bourne, Rupert R A" sort="Bourne, Rupert R A" uniqKey="Bourne R" first="Rupert R A" last="Bourne">Rupert R A. Bourne</name>
</author>
<author>
<name sortKey="Restori, Marie" sort="Restori, Marie" uniqKey="Restori M" first="Marie" last="Restori">Marie Restori</name>
</author>
<author>
<name sortKey="Allan, Bruce D S" sort="Allan, Bruce D S" uniqKey="Allan B" first="Bruce D S" last="Allan">Bruce D S. Allan</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2007">2007</date>
<idno type="doi">10.1016/j.ajo.2007.02.043</idno>
<idno type="RBID">pubmed:17524766</idno>
<idno type="pmid">17524766</idno>
<idno type="wicri:Area/PubMed/Corpus">001627</idno>
<idno type="wicri:Area/PubMed/Curation">001627</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia.</title>
<author>
<name sortKey="Maclaren, Robert E" sort="Maclaren, Robert E" uniqKey="Maclaren R" first="Robert E" last="Maclaren">Robert E. Maclaren</name>
<affiliation wicri:level="1">
<nlm:affiliation>Moorfields Eye Hospital, City Road, London, United Kingdom. robert.maclaren@moorfields.nhs.uk</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Moorfields Eye Hospital, City Road, London</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Natkunarajah, Mythili" sort="Natkunarajah, Mythili" uniqKey="Natkunarajah M" first="Mythili" last="Natkunarajah">Mythili Natkunarajah</name>
</author>
<author>
<name sortKey="Riaz, Yasmin" sort="Riaz, Yasmin" uniqKey="Riaz Y" first="Yasmin" last="Riaz">Yasmin Riaz</name>
</author>
<author>
<name sortKey="Bourne, Rupert R A" sort="Bourne, Rupert R A" uniqKey="Bourne R" first="Rupert R A" last="Bourne">Rupert R A. Bourne</name>
</author>
<author>
<name sortKey="Restori, Marie" sort="Restori, Marie" uniqKey="Restori M" first="Marie" last="Restori">Marie Restori</name>
</author>
<author>
<name sortKey="Allan, Bruce D S" sort="Allan, Bruce D S" uniqKey="Allan B" first="Bruce D S" last="Allan">Bruce D S. Allan</name>
</author>
</analytic>
<series>
<title level="j">American journal of ophthalmology</title>
<idno type="ISSN">0002-9394</idno>
<imprint>
<date when="2007" type="published">2007</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Anterior Chamber (anatomy & histology)</term>
<term>Anterior Chamber (ultrasonography)</term>
<term>Biometry</term>
<term>Cataract Extraction</term>
<term>Cornea (anatomy & histology)</term>
<term>Humans</term>
<term>Hyperopia (surgery)</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Medical Audit</term>
<term>Models, Theoretical</term>
<term>Patient Satisfaction</term>
<term>Postoperative Period</term>
<term>Refraction, Ocular (physiology)</term>
<term>Reproducibility of Results</term>
<term>Retrospective Studies</term>
<term>Visual Acuity (physiology)</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomy & histology" xml:lang="en">
<term>Anterior Chamber</term>
<term>Cornea</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Refraction, Ocular</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Hyperopia</term>
</keywords>
<keywords scheme="MESH" qualifier="ultrasonography" xml:lang="en">
<term>Anterior Chamber</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Biometry</term>
<term>Cataract Extraction</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Medical Audit</term>
<term>Models, Theoretical</term>
<term>Patient Satisfaction</term>
<term>Postoperative Period</term>
<term>Reproducibility of Results</term>
<term>Retrospective Studies</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To audit intraocular lens (IOL) power predictions for cataract surgery in extreme hyperopia and to compare the accuracy across different biometry formulae and IOL types.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">17524766</PMID>
<DateCreated>
<Year>2007</Year>
<Month>05</Month>
<Day>25</Day>
</DateCreated>
<DateCompleted>
<Year>2007</Year>
<Month>06</Month>
<Day>28</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>02</Month>
<Day>19</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0002-9394</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>143</Volume>
<Issue>6</Issue>
<PubDate>
<Year>2007</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>American journal of ophthalmology</Title>
<ISOAbbreviation>Am. J. Ophthalmol.</ISOAbbreviation>
</Journal>
<ArticleTitle>Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia.</ArticleTitle>
<Pagination>
<MedlinePgn>920-931</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To audit intraocular lens (IOL) power predictions for cataract surgery in extreme hyperopia and to compare the accuracy across different biometry formulae and IOL types.</AbstractText>
<AbstractText Label="DESIGN" NlmCategory="METHODS">A retrospective analysis of 76 eyes from 56 patients undergoing cataract surgery with IOLs ranging in power from 30 to 35 diopters (D).</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Axial lengths, corneal powers and anterior chamber depths were measured with ultrasound or optical methods, and the IOLMaster (Carl Zeiss Meditech, Inc, Dublin, California, USA) software was used to predict the refractive outcome for each IOL used. Differences between the predicted and actual postoperative refraction were then analyzed for each formula.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">In practice, 55% of patients were within +/-1.0 D of the refraction predicted by their surgeon. In theory, the Haigis formula would have given the smallest mean refractive error (+0.51 +/- 0.12 D), followed by the Hoffer Q (-0.70 +/- 0.14 D), Holladay 1 (-1.11 +/- 0.13 D), and SRK/T formulae (-1.45 +/- 0.14 D). The Haigis formula overpredicted the lens power required, which would have generated a myopic result. The other formulae underpredicted the lens power required and would have generated a hyperopic result. There was a significant difference between lens designs: the Haigis was more accurate for open-loop, whereas the Hoffer Q was more accurate for plate-haptic lenses. The anterior chamber depth measurement could also be used to predict changes in intraocular pressure after surgery.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">This represents the largest published series to date of biometry predictions for cataract surgery in extreme hyperopia and confirms the Haigis formula to be the most accurate. A consistent difference between open-loop and plate-haptic lenses suggests that haptic design may influence the effective lens position in very small eyes. We further propose a simple formula to optimize the Haigis and Hoffer Q formulae in patients with extreme hyperopia.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>MacLaren</LastName>
<ForeName>Robert E</ForeName>
<Initials>RE</Initials>
<AffiliationInfo>
<Affiliation>Moorfields Eye Hospital, City Road, London, United Kingdom. robert.maclaren@moorfields.nhs.uk</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Natkunarajah</LastName>
<ForeName>Mythili</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Riaz</LastName>
<ForeName>Yasmin</ForeName>
<Initials>Y</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Bourne</LastName>
<ForeName>Rupert R A</ForeName>
<Initials>RR</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Restori</LastName>
<ForeName>Marie</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Allan</LastName>
<ForeName>Bruce D S</ForeName>
<Initials>BD</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<GrantList CompleteYN="Y">
<Grant>
<GrantID>G0601588</GrantID>
<Agency>Medical Research Council</Agency>
<Country>United Kingdom</Country>
</Grant>
</GrantList>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Am J Ophthalmol</MedlineTA>
<NlmUniqueID>0370500</NlmUniqueID>
<ISSNLinking>0002-9394</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>AIM</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000867">Anterior Chamber</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000033">anatomy & histology</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000736">ultrasonography</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D001699">Biometry</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D002387">Cataract Extraction</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003315">Cornea</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000033">anatomy & histology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006956">Hyperopia</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008485">Medical Audit</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D008962">Models, Theoretical</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D017060">Patient Satisfaction</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011184">Postoperative Period</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012029">Refraction, Ocular</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D015203">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012189">Retrospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2006</Year>
<Month>6</Month>
<Day>27</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised">
<Year>2007</Year>
<Month>2</Month>
<Day>11</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2007</Year>
<Month>2</Month>
<Day>14</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2007</Year>
<Month>5</Month>
<Day>26</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2007</Year>
<Month>6</Month>
<Day>29</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2007</Year>
<Month>5</Month>
<Day>26</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0002-9394(07)00233-4</ArticleId>
<ArticleId IdType="doi">10.1016/j.ajo.2007.02.043</ArticleId>
<ArticleId IdType="pubmed">17524766</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001627 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 001627 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:17524766
   |texte=   Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:17524766" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024