Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.
Identifieur interne : 001374 ( PubMed/Curation ); précédent : 001373; suivant : 001375Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.
Auteurs : David F. Chang [États-Unis]Source :
- Journal of cataract and refractive surgery [ 0886-3350 ] ; 2008.
English descriptors
- KwdEn :
- Acrylic Resins, Adolescent, Adult, Aged, Aged, 80 and over, Astigmatism (physiopathology), Astigmatism (therapy), Biocompatible Materials, Humans, Lens Implantation, Intraocular, Lenses, Intraocular, Middle Aged, Phacoemulsification, Prospective Studies, Prosthesis Design, Refraction, Ocular (physiology), Retrospective Studies, Rotation, Silicone Elastomers, Young Adult.
- MESH :
- chemical : Acrylic Resins, Biocompatible Materials, Silicone Elastomers.
- physiology : Refraction, Ocular.
- physiopathology : Astigmatism.
- therapy : Astigmatism.
- Adolescent, Adult, Aged, Aged, 80 and over, Humans, Lens Implantation, Intraocular, Lenses, Intraocular, Middle Aged, Phacoemulsification, Prospective Studies, Prosthesis Design, Retrospective Studies, Rotation, Young Adult.
Abstract
To prospectively compare the early rotational stability of AcrySof SN60T toric intraocular lenses (IOLs) with that in a retrospective series of AA4203 toric IOLs.
DOI: 10.1016/j.jcrs.2008.07.012
PubMed: 19006728
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :001374
Links to Exploration step
pubmed:19006728Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.</title>
<author><name sortKey="Chang, David F" sort="Chang, David F" uniqKey="Chang D" first="David F" last="Chang">David F. Chang</name>
<affiliation wicri:level="1"><nlm:affiliation>Private Practice in Los Altos, California, USA. dceye@earthlink.net</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Private Practice in Los Altos, California</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2008">2008</date>
<idno type="doi">10.1016/j.jcrs.2008.07.012</idno>
<idno type="RBID">pubmed:19006728</idno>
<idno type="pmid">19006728</idno>
<idno type="wicri:Area/PubMed/Corpus">001374</idno>
<idno type="wicri:Area/PubMed/Curation">001374</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.</title>
<author><name sortKey="Chang, David F" sort="Chang, David F" uniqKey="Chang D" first="David F" last="Chang">David F. Chang</name>
<affiliation wicri:level="1"><nlm:affiliation>Private Practice in Los Altos, California, USA. dceye@earthlink.net</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Private Practice in Los Altos, California</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series><title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint><date when="2008" type="published">2008</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Acrylic Resins</term>
<term>Adolescent</term>
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Astigmatism (physiopathology)</term>
<term>Astigmatism (therapy)</term>
<term>Biocompatible Materials</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Middle Aged</term>
<term>Phacoemulsification</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
<term>Refraction, Ocular (physiology)</term>
<term>Retrospective Studies</term>
<term>Rotation</term>
<term>Silicone Elastomers</term>
<term>Young Adult</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Acrylic Resins</term>
<term>Biocompatible Materials</term>
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en"><term>Refraction, Ocular</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en"><term>Astigmatism</term>
</keywords>
<keywords scheme="MESH" qualifier="therapy" xml:lang="en"><term>Astigmatism</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adolescent</term>
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Middle Aged</term>
<term>Phacoemulsification</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
<term>Retrospective Studies</term>
<term>Rotation</term>
<term>Young Adult</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To prospectively compare the early rotational stability of AcrySof SN60T toric intraocular lenses (IOLs) with that in a retrospective series of AA4203 toric IOLs.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">19006728</PMID>
<DateCreated><Year>2008</Year>
<Month>11</Month>
<Day>13</Day>
</DateCreated>
<DateCompleted><Year>2008</Year>
<Month>12</Month>
<Day>16</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print"><Volume>34</Volume>
<Issue>11</Issue>
<PubDate><Year>2008</Year>
<Month>Nov</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.</ArticleTitle>
<Pagination><MedlinePgn>1842-7</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.jcrs.2008.07.012</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To prospectively compare the early rotational stability of AcrySof SN60T toric intraocular lenses (IOLs) with that in a retrospective series of AA4203 toric IOLs.</AbstractText>
<AbstractText Label="SETTING" NlmCategory="METHODS">Private practice, Los Altos, California, USA.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">One hundred consecutive eyes with an AcrySof SN60T(3, 4, or 5) toric IOL were compared with a consecutive series of 90 AA4203 (TL or TF) toric IOLs. The same surgeon performed all IOL implantations using an identical surgical technique. In addition to deviation from the desired axis, the change in refractive cylinder was measured 1 month postoperatively.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Although surgery was performed during different time periods, the 2 populations had a similar distribution of patient age, axial lengths, and spherical IOL powers. In the AcrySof SN60T group, 90%, 99%, and 100% of the IOLs were aligned at or within 5, 10, and 15 degrees, respectively, of the desired axis and in the AA4203 group, 70%, 90%, and 97%, respectively. The mean IOL rotation was 5.56 degrees +/- 8.49 (SD) in the AA4203 group and 3.35 +/- 3.41 degrees in the AcrySof SN60T group (P = .0232). One AcrySof SN60T IOL (1%) and 8 AA4203 IOLs (8.9%) were 15 degrees or more off axis (P = .01). No AcrySof SN60T IOL and 3.3% of AA4203 IOLs required surgical repositioning.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Both toric IOLs had good rotational stability and were effective in reducing preexisting corneal astigmatism. Based on the mean axis deviation and the number of IOLs rotating 15 degrees or more, the AcrySof SN60T toric IOL showed statistically better rotational stability.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Chang</LastName>
<ForeName>David F</ForeName>
<Initials>DF</Initials>
<AffiliationInfo><Affiliation>Private Practice in Los Altos, California, USA. dceye@earthlink.net</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D001672">Biocompatible Materials</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012826">Silicone Elastomers</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="Y" UI="D000180">Acrylic Resins</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000293">Adolescent</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D001251">Astigmatism</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000503">physiopathology</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000628">therapy</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D001672">Biocompatible Materials</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011446">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012029">Refraction, Ocular</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012189">Retrospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D012399">Rotation</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D012826">Silicone Elastomers</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D055815">Young Adult</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="received"><Year>2008</Year>
<Month>5</Month>
<Day>10</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted"><Year>2008</Year>
<Month>7</Month>
<Day>18</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2008</Year>
<Month>11</Month>
<Day>14</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2008</Year>
<Month>12</Month>
<Day>17</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2008</Year>
<Month>11</Month>
<Day>14</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pii">S0886-3350(08)00783-9</ArticleId>
<ArticleId IdType="doi">10.1016/j.jcrs.2008.07.012</ArticleId>
<ArticleId IdType="pubmed">19006728</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001374 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 001374 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Curation |type= RBID |clé= pubmed:19006728 |texte= Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i -Sk "pubmed:19006728" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |