Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Impact of intraocular lens haptic design and orientation on decentration and tilt.

Identifieur interne : 000E23 ( PubMed/Curation ); précédent : 000E22; suivant : 000E24

Impact of intraocular lens haptic design and orientation on decentration and tilt.

Auteurs : Alja Crnej [Royaume-Uni] ; Nino Hirnschall ; Yutaro Nishi ; Vinod Gangwani ; Juan Tabernero ; Pablo Artal ; Oliver Findl

Source :

RBID : pubmed:21840681

English descriptors

Abstract

To assess the effect of intraocular lens (IOL) orientation (vertical versus horizontal) and haptic design (1-piece versus 3-piece) on centration and tilt using a Purkinje meter.

DOI: 10.1016/j.jcrs.2011.04.028
PubMed: 21840681

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:21840681

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Impact of intraocular lens haptic design and orientation on decentration and tilt.</title>
<author>
<name sortKey="Crnej, Alja" sort="Crnej, Alja" uniqKey="Crnej A" first="Alja" last="Crnej">Alja Crnej</name>
<affiliation wicri:level="1">
<nlm:affiliation>Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Moorfields Eye Hospital NHS Foundation Trust, London</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Hirnschall, Nino" sort="Hirnschall, Nino" uniqKey="Hirnschall N" first="Nino" last="Hirnschall">Nino Hirnschall</name>
</author>
<author>
<name sortKey="Nishi, Yutaro" sort="Nishi, Yutaro" uniqKey="Nishi Y" first="Yutaro" last="Nishi">Yutaro Nishi</name>
</author>
<author>
<name sortKey="Gangwani, Vinod" sort="Gangwani, Vinod" uniqKey="Gangwani V" first="Vinod" last="Gangwani">Vinod Gangwani</name>
</author>
<author>
<name sortKey="Tabernero, Juan" sort="Tabernero, Juan" uniqKey="Tabernero J" first="Juan" last="Tabernero">Juan Tabernero</name>
</author>
<author>
<name sortKey="Artal, Pablo" sort="Artal, Pablo" uniqKey="Artal P" first="Pablo" last="Artal">Pablo Artal</name>
</author>
<author>
<name sortKey="Findl, Oliver" sort="Findl, Oliver" uniqKey="Findl O" first="Oliver" last="Findl">Oliver Findl</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2011">2011</date>
<idno type="doi">10.1016/j.jcrs.2011.04.028</idno>
<idno type="RBID">pubmed:21840681</idno>
<idno type="pmid">21840681</idno>
<idno type="wicri:Area/PubMed/Corpus">000E23</idno>
<idno type="wicri:Area/PubMed/Curation">000E23</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Impact of intraocular lens haptic design and orientation on decentration and tilt.</title>
<author>
<name sortKey="Crnej, Alja" sort="Crnej, Alja" uniqKey="Crnej A" first="Alja" last="Crnej">Alja Crnej</name>
<affiliation wicri:level="1">
<nlm:affiliation>Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Moorfields Eye Hospital NHS Foundation Trust, London</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Hirnschall, Nino" sort="Hirnschall, Nino" uniqKey="Hirnschall N" first="Nino" last="Hirnschall">Nino Hirnschall</name>
</author>
<author>
<name sortKey="Nishi, Yutaro" sort="Nishi, Yutaro" uniqKey="Nishi Y" first="Yutaro" last="Nishi">Yutaro Nishi</name>
</author>
<author>
<name sortKey="Gangwani, Vinod" sort="Gangwani, Vinod" uniqKey="Gangwani V" first="Vinod" last="Gangwani">Vinod Gangwani</name>
</author>
<author>
<name sortKey="Tabernero, Juan" sort="Tabernero, Juan" uniqKey="Tabernero J" first="Juan" last="Tabernero">Juan Tabernero</name>
</author>
<author>
<name sortKey="Artal, Pablo" sort="Artal, Pablo" uniqKey="Artal P" first="Pablo" last="Artal">Pablo Artal</name>
</author>
<author>
<name sortKey="Findl, Oliver" sort="Findl, Oliver" uniqKey="Findl O" first="Oliver" last="Findl">Oliver Findl</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="eISSN">1873-4502</idno>
<imprint>
<date when="2011" type="published">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Artificial Lens Implant Migration</term>
<term>Diagnostic Techniques, Ophthalmological</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Phacoemulsification</term>
<term>Pilot Projects</term>
<term>Prosthesis Design</term>
<term>Prosthesis Failure</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Artificial Lens Implant Migration</term>
<term>Diagnostic Techniques, Ophthalmological</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Phacoemulsification</term>
<term>Pilot Projects</term>
<term>Prosthesis Design</term>
<term>Prosthesis Failure</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To assess the effect of intraocular lens (IOL) orientation (vertical versus horizontal) and haptic design (1-piece versus 3-piece) on centration and tilt using a Purkinje meter.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">21840681</PMID>
<DateCreated>
<Year>2011</Year>
<Month>09</Month>
<Day>20</Day>
</DateCreated>
<DateCompleted>
<Year>2011</Year>
<Month>12</Month>
<Day>21</Day>
</DateCompleted>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1873-4502</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>37</Volume>
<Issue>10</Issue>
<PubDate>
<Year>2011</Year>
<Month>Oct</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Impact of intraocular lens haptic design and orientation on decentration and tilt.</ArticleTitle>
<Pagination>
<MedlinePgn>1768-74</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.jcrs.2011.04.028</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To assess the effect of intraocular lens (IOL) orientation (vertical versus horizontal) and haptic design (1-piece versus 3-piece) on centration and tilt using a Purkinje meter.</AbstractText>
<AbstractText Label="SETTING" NlmCategory="METHODS">Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.</AbstractText>
<AbstractText Label="DESIGN" NlmCategory="METHODS">Randomized pilot study with intrapatient comparison.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">In part 1 of this study, patients received plate-haptic IOLs (Akreos Adapt) in both eyes that were positioned vertically in 1 eye and horizontally in the other eye. In part 2, patients received a 1-piece IOL (Acrysof SA60AT) in 1 eye and a 3-piece IOL (Acrysof MA60AC) in the contralateral eye. Decentration and tilt were measured 1 month and 3 months postoperatively with a new Purkinje meter.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">In part 1 (n = 15), the mean decentration of plate-haptic IOLs was 0.4 mm ± 0.2 (SD) with vertical orientation and 0.4 ± 0.2 mm with horizontal orientation and the mean tilt, 1.5 ± 1.1 degrees and 2.9 ± 0.9 degrees, respectively. In part 2 (n = 15), the mean decentration was 0.4 ± 0.3 mm with 1-piece IOLs and 0.6 ± 0.8 mm with 3-piece IOLs and the mean tilt, 2.2 ± 7.2 degrees and 5.3 ± 2.4 degrees, respectively.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Three-piece IOLs had a greater tendency toward more decentration than 1-piece IOLs, perhaps because of slight deformation of 1 or both haptics during implantation or inaccuracies in production when the haptics are manually placed into the optic. The IOL orientation for plate-haptic IOLs appeared to have no effect on IOL position. The Purkinje meter was useful in assessing the capsule bag performance of the IOLs.</AbstractText>
<AbstractText Label="FINANCIAL DISCLOSURE" NlmCategory="BACKGROUND">No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.</AbstractText>
<CopyrightInformation>Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Crnej</LastName>
<ForeName>Alja</ForeName>
<Initials>A</Initials>
<AffiliationInfo>
<Affiliation>Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Hirnschall</LastName>
<ForeName>Nino</ForeName>
<Initials>N</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Nishi</LastName>
<ForeName>Yutaro</ForeName>
<Initials>Y</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Gangwani</LastName>
<ForeName>Vinod</ForeName>
<Initials>V</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Tabernero</LastName>
<ForeName>Juan</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Artal</LastName>
<ForeName>Pablo</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Findl</LastName>
<ForeName>Oliver</ForeName>
<Initials>O</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D016449">Randomized Controlled Trial</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2011</Year>
<Month>08</Month>
<Day>15</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D060437">Artificial Lens Implant Migration</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003941">Diagnostic Techniques, Ophthalmological</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005500">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D055095">Optics and Photonics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D010865">Pilot Projects</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011475">Prosthesis Failure</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2010</Year>
<Month>12</Month>
<Day>17</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised">
<Year>2011</Year>
<Month>4</Month>
<Day>11</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2011</Year>
<Month>4</Month>
<Day>11</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="aheadofprint">
<Year>2011</Year>
<Month>8</Month>
<Day>15</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2011</Year>
<Month>8</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2011</Year>
<Month>8</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2011</Year>
<Month>12</Month>
<Day>22</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0886-3350(11)01073-X</ArticleId>
<ArticleId IdType="doi">10.1016/j.jcrs.2011.04.028</ArticleId>
<ArticleId IdType="pubmed">21840681</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000E23 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000E23 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:21840681
   |texte=   Impact of intraocular lens haptic design and orientation on decentration and tilt.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:21840681" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024