Sleeveless-extrusion cannula for levitation of dislocated intraocular lens.

Identifieur interne : 000752 ( PubMed/Curation ); précédent : 000751; suivant : 000753

Sleeveless-extrusion cannula for levitation of dislocated intraocular lens.

Auteurs : Ashvin Agarwal ; Priya Narang ; Amar Agarwal ; Dhivya A. Kumar

Source :

RBID : pubmed:24511083

English descriptors

Abstract

To characterise a sleeveless-extrusion cannula-based suction technique to levitate dislocated intraocular lens (IOLs) and review the surgical outcome.

DOI: 10.1136/bjophthalmol-2013-304700
PubMed: 24511083

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:24511083

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Sleeveless-extrusion cannula for levitation of dislocated intraocular lens.</title>
<author>
<name sortKey="Agarwal, Ashvin" sort="Agarwal, Ashvin" uniqKey="Agarwal A" first="Ashvin" last="Agarwal">Ashvin Agarwal</name>
</author>
<author>
<name sortKey="Narang, Priya" sort="Narang, Priya" uniqKey="Narang P" first="Priya" last="Narang">Priya Narang</name>
</author>
<author>
<name sortKey="Agarwal, Amar" sort="Agarwal, Amar" uniqKey="Agarwal A" first="Amar" last="Agarwal">Amar Agarwal</name>
</author>
<author>
<name sortKey="Kumar, Dhivya A" sort="Kumar, Dhivya A" uniqKey="Kumar D" first="Dhivya A" last="Kumar">Dhivya A. Kumar</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="doi">10.1136/bjophthalmol-2013-304700</idno>
<idno type="RBID">pubmed:24511083</idno>
<idno type="pmid">24511083</idno>
<idno type="wicri:Area/PubMed/Corpus">000752</idno>
<idno type="wicri:Area/PubMed/Curation">000752</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Sleeveless-extrusion cannula for levitation of dislocated intraocular lens.</title>
<author>
<name sortKey="Agarwal, Ashvin" sort="Agarwal, Ashvin" uniqKey="Agarwal A" first="Ashvin" last="Agarwal">Ashvin Agarwal</name>
</author>
<author>
<name sortKey="Narang, Priya" sort="Narang, Priya" uniqKey="Narang P" first="Priya" last="Narang">Priya Narang</name>
</author>
<author>
<name sortKey="Agarwal, Amar" sort="Agarwal, Amar" uniqKey="Agarwal A" first="Amar" last="Agarwal">Amar Agarwal</name>
</author>
<author>
<name sortKey="Kumar, Dhivya A" sort="Kumar, Dhivya A" uniqKey="Kumar D" first="Dhivya A" last="Kumar">Dhivya A. Kumar</name>
</author>
</analytic>
<series>
<title level="j">The British journal of ophthalmology</title>
<idno type="eISSN">1468-2079</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Artificial Lens Implant Migration (surgery)</term>
<term>Catheters</term>
<term>Female</term>
<term>Humans</term>
<term>Intraoperative Complications</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Postoperative Complications</term>
<term>Reoperation</term>
<term>Reproducibility of Results</term>
<term>Retrospective Studies</term>
<term>Suction (instrumentation)</term>
<term>Visual Acuity (physiology)</term>
<term>Vitrectomy</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Suction</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Artificial Lens Implant Migration</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Catheters</term>
<term>Female</term>
<term>Humans</term>
<term>Intraoperative Complications</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Postoperative Complications</term>
<term>Reoperation</term>
<term>Reproducibility of Results</term>
<term>Retrospective Studies</term>
<term>Vitrectomy</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To characterise a sleeveless-extrusion cannula-based suction technique to levitate dislocated intraocular lens (IOLs) and review the surgical outcome.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">24511083</PMID>
<DateCreated>
<Year>2014</Year>
<Month>07</Month>
<Day>28</Day>
</DateCreated>
<DateCompleted>
<Year>2014</Year>
<Month>08</Month>
<Day>29</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1468-2079</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>98</Volume>
<Issue>7</Issue>
<PubDate>
<Year>2014</Year>
<Month>Jul</Month>
</PubDate>
</JournalIssue>
<Title>The British journal of ophthalmology</Title>
<ISOAbbreviation>Br J Ophthalmol</ISOAbbreviation>
</Journal>
<ArticleTitle>Sleeveless-extrusion cannula for levitation of dislocated intraocular lens.</ArticleTitle>
<Pagination>
<MedlinePgn>910-4</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND/AIMS" NlmCategory="OBJECTIVE">To characterise a sleeveless-extrusion cannula-based suction technique to levitate dislocated intraocular lens (IOLs) and review the surgical outcome.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">This retrospective, non-comparative, single surgeon, interventional, consecutive case series examined 10 patients (10 eyes) who underwent the surgical procedure from October 2011 to December 2012. Reliability, reproducibility, and intraoperative and postoperative complications of the technique were analysed.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The technique involved suction levitation of a 3-piece acrylic foldable IOL in six cases, 1-piece acrylic foldable IOL in three cases and a plate haptic IOL in one case. The IOL was exchanged in four eyes whereas the same IOL was repositioned in six eyes with sulcus repositioning in two eyes and glued intrascleral fixation in four eyes. Intraoperative suction loss and a subsequent IOL dislocation were reported in 1 (10%) eye. Early preoperative complications included pigment dispersion in 1 (10%) eye, grade 2 anterior chamber cellular reaction in 2 (20%) eyes and intraoperative corneal oedema in 1 (10%) eye which resolved with medical line of management. Intermediate and late complications included macular oedema in one patient (10%) which resolved considerably with medical line of management. No incidence of postoperative vitreous or retinal haemorrhage, retinal break or retinal detachment was reported.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">The early results demonstrate this surgical intervention as a reliable, reproducible and an effective alternative treatment option for levitation of dislocated IOLs with a low complication rate.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Agarwal</LastName>
<ForeName>Ashvin</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Narang</LastName>
<ForeName>Priya</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Agarwal</LastName>
<ForeName>Amar</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Kumar</LastName>
<ForeName>Dhivya A</ForeName>
<Initials>DA</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>Br J Ophthalmol</MedlineTA>
<NlmUniqueID>0421041</NlmUniqueID>
<ISSNLinking>0007-1161</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D060437">Artificial Lens Implant Migration</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D057785">Catheters</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007431">Intraoperative Complications</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011183">Postoperative Complications</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012086">Reoperation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D015203">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012189">Retrospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013396">Suction</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014821">Vitrectomy</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>2</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>2</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2014</Year>
<Month>8</Month>
<Day>30</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">bjophthalmol-2013-304700</ArticleId>
<ArticleId IdType="doi">10.1136/bjophthalmol-2013-304700</ArticleId>
<ArticleId IdType="pubmed">24511083</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000752 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000752 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:24511083
   |texte=   Sleeveless-extrusion cannula for levitation of dislocated intraocular lens.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:24511083" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024