Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.

Identifieur interne : 000629 ( PubMed/Curation ); précédent : 000628; suivant : 000630

Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.

Auteurs : Mengmeng Wang [Japon] ; Christine Carole C. Corpuz [Japon] ; Megumi Fujiwara [Japon] ; Minoru Tomita [République populaire de Chine]

Source :

RBID : pubmed:24868143

Abstract

To evaluate and compare the visual acuity outcomes and optical performances of eyes implanted with two diffractive multifocal intraocular lens (IOL) models with either a plate haptic design or a modified-C design.

DOI: 10.2147/OPTH.S60493
PubMed: 24868143

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:24868143

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.</title>
<author>
<name sortKey="Wang, Mengmeng" sort="Wang, Mengmeng" uniqKey="Wang M" first="Mengmeng" last="Wang">Mengmeng Wang</name>
<affiliation wicri:level="1">
<nlm:affiliation>Shinagawa LASIK Center, Tokyo, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Shinagawa LASIK Center, Tokyo</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Corpuz, Christine Carole C" sort="Corpuz, Christine Carole C" uniqKey="Corpuz C" first="Christine Carole C" last="Corpuz">Christine Carole C. Corpuz</name>
<affiliation wicri:level="1">
<nlm:affiliation>Shinagawa LASIK Center, Tokyo, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Shinagawa LASIK Center, Tokyo</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Fujiwara, Megumi" sort="Fujiwara, Megumi" uniqKey="Fujiwara M" first="Megumi" last="Fujiwara">Megumi Fujiwara</name>
<affiliation wicri:level="1">
<nlm:affiliation>Shinagawa LASIK Center, Tokyo, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Shinagawa LASIK Center, Tokyo</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Tomita, Minoru" sort="Tomita, Minoru" uniqKey="Tomita M" first="Minoru" last="Tomita">Minoru Tomita</name>
<affiliation wicri:level="1">
<nlm:affiliation>Shinagawa LASIK Center, Tokyo, Japan ; Department of Ophthalmology, Wenzhou Medical College, Wenzhou, People's Republic of China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Shinagawa LASIK Center, Tokyo, Japan ; Department of Ophthalmology, Wenzhou Medical College, Wenzhou</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="doi">10.2147/OPTH.S60493</idno>
<idno type="RBID">pubmed:24868143</idno>
<idno type="pmid">24868143</idno>
<idno type="wicri:Area/PubMed/Corpus">000629</idno>
<idno type="wicri:Area/PubMed/Curation">000629</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.</title>
<author>
<name sortKey="Wang, Mengmeng" sort="Wang, Mengmeng" uniqKey="Wang M" first="Mengmeng" last="Wang">Mengmeng Wang</name>
<affiliation wicri:level="1">
<nlm:affiliation>Shinagawa LASIK Center, Tokyo, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Shinagawa LASIK Center, Tokyo</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Corpuz, Christine Carole C" sort="Corpuz, Christine Carole C" uniqKey="Corpuz C" first="Christine Carole C" last="Corpuz">Christine Carole C. Corpuz</name>
<affiliation wicri:level="1">
<nlm:affiliation>Shinagawa LASIK Center, Tokyo, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Shinagawa LASIK Center, Tokyo</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Fujiwara, Megumi" sort="Fujiwara, Megumi" uniqKey="Fujiwara M" first="Megumi" last="Fujiwara">Megumi Fujiwara</name>
<affiliation wicri:level="1">
<nlm:affiliation>Shinagawa LASIK Center, Tokyo, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Shinagawa LASIK Center, Tokyo</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Tomita, Minoru" sort="Tomita, Minoru" uniqKey="Tomita M" first="Minoru" last="Tomita">Minoru Tomita</name>
<affiliation wicri:level="1">
<nlm:affiliation>Shinagawa LASIK Center, Tokyo, Japan ; Department of Ophthalmology, Wenzhou Medical College, Wenzhou, People's Republic of China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Shinagawa LASIK Center, Tokyo, Japan ; Department of Ophthalmology, Wenzhou Medical College, Wenzhou</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Clinical ophthalmology (Auckland, N.Z.)</title>
<idno type="ISSN">1177-5467</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To evaluate and compare the visual acuity outcomes and optical performances of eyes implanted with two diffractive multifocal intraocular lens (IOL) models with either a plate haptic design or a modified-C design.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="PubMed-not-MEDLINE">
<PMID Version="1">24868143</PMID>
<DateCreated>
<Year>2014</Year>
<Month>05</Month>
<Day>28</Day>
</DateCreated>
<DateCompleted>
<Year>2014</Year>
<Month>05</Month>
<Day>28</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>05</Month>
<Day>30</Day>
</DateRevised>
<Article PubModel="Electronic-eCollection">
<Journal>
<ISSN IssnType="Print">1177-5467</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>8</Volume>
<PubDate>
<Year>2014</Year>
</PubDate>
</JournalIssue>
<Title>Clinical ophthalmology (Auckland, N.Z.)</Title>
<ISOAbbreviation>Clin Ophthalmol</ISOAbbreviation>
</Journal>
<ArticleTitle>Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.</ArticleTitle>
<Pagination>
<MedlinePgn>919-26</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.2147/OPTH.S60493</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To evaluate and compare the visual acuity outcomes and optical performances of eyes implanted with two diffractive multifocal intraocular lens (IOL) models with either a plate haptic design or a modified-C design.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">This retrospective study comprised cataract patients who were implanted with either a plate haptic multifocal IOL model (Acriva(UD) Reviol BB MFM 611 [VSY Biotechnology, Amsterdam, the Netherlands], group 1) or a modified-C haptic multifocal IOL model (Acriva(UD) Reviol BB MF 613 [VSY Biotechnology, Amsterdam, the Netherlands], group 2) between June 2012 and May 2013. The 6 month postoperative visual acuity, refraction, defocus curve, contrast sensitivity, and wave-front aberration were evaluated and compared between these eyes, using different IOL models.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">One hundred fifty-eight eyes of 107 patients were included in this study. Significant improvement in visual acuities and refraction was found in both groups after cataract surgery (P<0.01). The visual acuity and contrast sensitivity were statistically better in group 1 than in group 2 (P<0.01). No statistically significant difference in the corneal higher-order aberrations was found between the two groups (P>0.05). However, the ocular higher-order aberrations in group 2 were significantly greater than in group 1 (P<0.05).</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">At 6 months postoperatively, both Acriva(UD) Reviol BB MFM 611 IOL and Acriva(UD) Reviol BB MF 613 IOL achieved excellent visual and refractive outcomes. The multifocal IOL model with plate haptic design resulted in better optical performances than that with the modified-C haptic design.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Wang</LastName>
<ForeName>Mengmeng</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Shinagawa LASIK Center, Tokyo, Japan.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Corpuz</LastName>
<ForeName>Christine Carole C</ForeName>
<Initials>CC</Initials>
<AffiliationInfo>
<Affiliation>Shinagawa LASIK Center, Tokyo, Japan.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Fujiwara</LastName>
<ForeName>Megumi</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Shinagawa LASIK Center, Tokyo, Japan.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Tomita</LastName>
<ForeName>Minoru</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Shinagawa LASIK Center, Tokyo, Japan ; Department of Ophthalmology, Wenzhou Medical College, Wenzhou, People's Republic of China.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2014</Year>
<Month>05</Month>
<Day>14</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>New Zealand</Country>
<MedlineTA>Clin Ophthalmol</MedlineTA>
<NlmUniqueID>101321512</NlmUniqueID>
<ISSNLinking>1177-5467</ISSNLinking>
</MedlineJournalInfo>
<OtherID Source="NLM">PMC4027939</OtherID>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">AcrivaUD</Keyword>
<Keyword MajorTopicYN="N">VSY</Keyword>
<Keyword MajorTopicYN="N">cataract surgery</Keyword>
<Keyword MajorTopicYN="N">modified-C haptic</Keyword>
<Keyword MajorTopicYN="N">multifocal intraocular lens</Keyword>
<Keyword MajorTopicYN="N">plate haptic</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="ecollection">
<Year>2014</Year>
<Month></Month>
<Day></Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="epublish">
<Year>2014</Year>
<Month>5</Month>
<Day>14</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>5</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>5</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2014</Year>
<Month>5</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>epublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.2147/OPTH.S60493</ArticleId>
<ArticleId IdType="pii">opth-8-919</ArticleId>
<ArticleId IdType="pubmed">24868143</ArticleId>
<ArticleId IdType="pmc">PMC4027939</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000629 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000629 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:24868143
   |texte=   Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:24868143" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024