Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A knotless, one-haptic fixation of posterior chamber intraocular lenses: one-year results.

Identifieur interne : 000410 ( PubMed/Curation ); précédent : 000409; suivant : 000411

A knotless, one-haptic fixation of posterior chamber intraocular lenses: one-year results.

Auteurs : Pipat Kongsap [Thaïlande]

Source :

RBID : pubmed:25709917

Abstract

To assess the results of a modified technique for scleral fixation of a posterior chamber intraocular lens (IOL) in eyes which had deficient of posterior capsular support.

DOI: 10.3980/j.issn.2222-3959.2015.01.19
PubMed: 25709917

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:25709917

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A knotless, one-haptic fixation of posterior chamber intraocular lenses: one-year results.</title>
<author>
<name sortKey="Kongsap, Pipat" sort="Kongsap, Pipat" uniqKey="Kongsap P" first="Pipat" last="Kongsap">Pipat Kongsap</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Prapokklao Hospital, Chanthaburi 22000, Thailand.</nlm:affiliation>
<country xml:lang="fr">Thaïlande</country>
<wicri:regionArea>Department of Ophthalmology, Prapokklao Hospital, Chanthaburi 22000</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="doi">10.3980/j.issn.2222-3959.2015.01.19</idno>
<idno type="RBID">pubmed:25709917</idno>
<idno type="pmid">25709917</idno>
<idno type="wicri:Area/PubMed/Corpus">000410</idno>
<idno type="wicri:Area/PubMed/Curation">000410</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A knotless, one-haptic fixation of posterior chamber intraocular lenses: one-year results.</title>
<author>
<name sortKey="Kongsap, Pipat" sort="Kongsap, Pipat" uniqKey="Kongsap P" first="Pipat" last="Kongsap">Pipat Kongsap</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Prapokklao Hospital, Chanthaburi 22000, Thailand.</nlm:affiliation>
<country xml:lang="fr">Thaïlande</country>
<wicri:regionArea>Department of Ophthalmology, Prapokklao Hospital, Chanthaburi 22000</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">International journal of ophthalmology</title>
<idno type="ISSN">2222-3959</idno>
<imprint>
<date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To assess the results of a modified technique for scleral fixation of a posterior chamber intraocular lens (IOL) in eyes which had deficient of posterior capsular support.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="PubMed-not-MEDLINE">
<PMID Version="1">25709917</PMID>
<DateCreated>
<Year>2015</Year>
<Month>02</Month>
<Day>24</Day>
</DateCreated>
<DateCompleted>
<Year>2015</Year>
<Month>02</Month>
<Day>24</Day>
</DateCompleted>
<DateRevised>
<Year>2015</Year>
<Month>02</Month>
<Day>26</Day>
</DateRevised>
<Article PubModel="Electronic-eCollection">
<Journal>
<ISSN IssnType="Print">2222-3959</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>8</Volume>
<Issue>1</Issue>
<PubDate>
<Year>2015</Year>
</PubDate>
</JournalIssue>
<Title>International journal of ophthalmology</Title>
<ISOAbbreviation>Int J Ophthalmol</ISOAbbreviation>
</Journal>
<ArticleTitle>A knotless, one-haptic fixation of posterior chamber intraocular lenses: one-year results.</ArticleTitle>
<Pagination>
<MedlinePgn>104-6</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.3980/j.issn.2222-3959.2015.01.19</ELocationID>
<Abstract>
<AbstractText Label="AIM" NlmCategory="OBJECTIVE">To assess the results of a modified technique for scleral fixation of a posterior chamber intraocular lens (IOL) in eyes which had deficient of posterior capsular support.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">This retrospective study was comprised of ten patients with deficient posterior capsular support who underwent one-haptic fixation of posterior chamber IOLs, between February 2010 and October 2011. IOL as implanted with one haptic supported on the capsular remnant and the other haptic drawn into the sulcus by anchoring suture without a knot. All patients were evaluated for pre- and postoperative visual acuity, lens centration, intra-and postoperative complications.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">A knotless, one-haptic fixation of posterior chamber IOLs has successfully been performed on ten eyes. All cases had inadequate capsular support (i.e. a capsular tear ranged from 5 to 7 clock hours). The average age was 74.25±8.87y (SD). The average postoperative uncorrected visual acuity was 0.51 logMAR. Complications included hyphema in one eye, a mild inflammatory reaction in the anterior chamber in two eyes, and a transient rise in IOP in one eye. Neither IOL tilt nor dislocation was observed and there were no later complications.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">In the presence of insufficient capsular support, a knotless, one-haptic fixation of posterior chamber IOLs is a safe and viable option which reduces the operation time, and minimizes postoperative suture-related complications.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Kongsap</LastName>
<ForeName>Pipat</ForeName>
<Initials>P</Initials>
<AffiliationInfo>
<Affiliation>Department of Ophthalmology, Prapokklao Hospital, Chanthaburi 22000, Thailand.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2015</Year>
<Month>02</Month>
<Day>18</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>China</Country>
<MedlineTA>Int J Ophthalmol</MedlineTA>
<NlmUniqueID>101553860</NlmUniqueID>
<ISSNLinking>2222-3959</ISSNLinking>
</MedlineJournalInfo>
<OtherID Source="NLM">PMC4325251</OtherID>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">intraocular lens</Keyword>
<Keyword MajorTopicYN="N">knotless technique</Keyword>
<Keyword MajorTopicYN="N">one-haptic fixation</Keyword>
<Keyword MajorTopicYN="N">scleral fixation</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="ecollection">
<Year>2015</Year>
<Month></Month>
<Day></Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="received">
<Year>2014</Year>
<Month>2</Month>
<Day>26</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2014</Year>
<Month>8</Month>
<Day>8</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="epublish">
<Year>2015</Year>
<Month>2</Month>
<Day>18</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2015</Year>
<Month>2</Month>
<Day>25</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2015</Year>
<Month>2</Month>
<Day>25</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>2</Month>
<Day>25</Day>
<Hour>6</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>epublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.3980/j.issn.2222-3959.2015.01.19</ArticleId>
<ArticleId IdType="pii">ijo-08-01-104</ArticleId>
<ArticleId IdType="pubmed">25709917</ArticleId>
<ArticleId IdType="pmc">PMC4325251</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000410 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000410 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:25709917
   |texte=   A knotless, one-haptic fixation of posterior chamber intraocular lenses: one-year results.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:25709917" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024