Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Location and composition of haptics of posterior chamber intraocular lenses. Histopathologic study of postmortem eyes.

Identifieur interne : 002317 ( PubMed/Corpus ); précédent : 002316; suivant : 002318

Location and composition of haptics of posterior chamber intraocular lenses. Histopathologic study of postmortem eyes.

Auteurs : P J Mcdonnell ; R. Champion ; W R Green

Source :

RBID : pubmed:3574878

English descriptors

Abstract

Of 110 eyes with posterior chamber intraocular lenses (IOLs) examined postmortem, 37% had both haptics outside of the capsular bag; 57% had one haptic in the capsular bag and the other haptic outside of the bag. Typically, these optics were decentered by 1 to 2 mm. Only six eyes (5%) had both haptics within the capsular bag. Erosion into the ciliary sulcus produced obliteration of the major arterial circle of the iris in 12 eyes (11%). The local tissue response to eroding haptics was similar for haptics composed of polypropylene and haptics composed of polymethylmethacrylate (PMMA). The authors found considerable discrepancy between the actual location of haptics and the surgeon's desired location (i.e., capsular bag or ciliary sulcus). Most of these cases were clinically successful.

PubMed: 3574878

Links to Exploration step

pubmed:3574878

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Location and composition of haptics of posterior chamber intraocular lenses. Histopathologic study of postmortem eyes.</title>
<author>
<name sortKey="Mcdonnell, P J" sort="Mcdonnell, P J" uniqKey="Mcdonnell P" first="P J" last="Mcdonnell">P J Mcdonnell</name>
</author>
<author>
<name sortKey="Champion, R" sort="Champion, R" uniqKey="Champion R" first="R" last="Champion">R. Champion</name>
</author>
<author>
<name sortKey="Green, W R" sort="Green, W R" uniqKey="Green W" first="W R" last="Green">W R Green</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1987">1987</date>
<idno type="RBID">pubmed:3574878</idno>
<idno type="pmid">3574878</idno>
<idno type="wicri:Area/PubMed/Corpus">002317</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Location and composition of haptics of posterior chamber intraocular lenses. Histopathologic study of postmortem eyes.</title>
<author>
<name sortKey="Mcdonnell, P J" sort="Mcdonnell, P J" uniqKey="Mcdonnell P" first="P J" last="Mcdonnell">P J Mcdonnell</name>
</author>
<author>
<name sortKey="Champion, R" sort="Champion, R" uniqKey="Champion R" first="R" last="Champion">R. Champion</name>
</author>
<author>
<name sortKey="Green, W R" sort="Green, W R" uniqKey="Green W" first="W R" last="Green">W R Green</name>
</author>
</analytic>
<series>
<title level="j">Ophthalmology</title>
<idno type="ISSN">0161-6420</idno>
<imprint>
<date when="1987" type="published">1987</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Ciliary Body (pathology)</term>
<term>Eye (pathology)</term>
<term>Humans</term>
<term>Iris (pathology)</term>
<term>Lens Capsule, Crystalline (pathology)</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Methods</term>
<term>Methylmethacrylates</term>
<term>Polypropylenes</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Methylmethacrylates</term>
<term>Polypropylenes</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Ciliary Body</term>
<term>Eye</term>
<term>Iris</term>
<term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Methods</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Of 110 eyes with posterior chamber intraocular lenses (IOLs) examined postmortem, 37% had both haptics outside of the capsular bag; 57% had one haptic in the capsular bag and the other haptic outside of the bag. Typically, these optics were decentered by 1 to 2 mm. Only six eyes (5%) had both haptics within the capsular bag. Erosion into the ciliary sulcus produced obliteration of the major arterial circle of the iris in 12 eyes (11%). The local tissue response to eroding haptics was similar for haptics composed of polypropylene and haptics composed of polymethylmethacrylate (PMMA). The authors found considerable discrepancy between the actual location of haptics and the surgeon's desired location (i.e., capsular bag or ciliary sulcus). Most of these cases were clinically successful.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">3574878</PMID>
<DateCreated>
<Year>1987</Year>
<Month>06</Month>
<Day>01</Day>
</DateCreated>
<DateCompleted>
<Year>1987</Year>
<Month>06</Month>
<Day>01</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0161-6420</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>94</Volume>
<Issue>2</Issue>
<PubDate>
<Year>1987</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>Ophthalmology</Title>
<ISOAbbreviation>Ophthalmology</ISOAbbreviation>
</Journal>
<ArticleTitle>Location and composition of haptics of posterior chamber intraocular lenses. Histopathologic study of postmortem eyes.</ArticleTitle>
<Pagination>
<MedlinePgn>136-42</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Of 110 eyes with posterior chamber intraocular lenses (IOLs) examined postmortem, 37% had both haptics outside of the capsular bag; 57% had one haptic in the capsular bag and the other haptic outside of the bag. Typically, these optics were decentered by 1 to 2 mm. Only six eyes (5%) had both haptics within the capsular bag. Erosion into the ciliary sulcus produced obliteration of the major arterial circle of the iris in 12 eyes (11%). The local tissue response to eroding haptics was similar for haptics composed of polypropylene and haptics composed of polymethylmethacrylate (PMMA). The authors found considerable discrepancy between the actual location of haptics and the surgeon's desired location (i.e., capsular bag or ciliary sulcus). Most of these cases were clinically successful.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>McDonnell</LastName>
<ForeName>P J</ForeName>
<Initials>PJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Champion</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Green</LastName>
<ForeName>W R</ForeName>
<Initials>WR</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>Ophthalmology</MedlineTA>
<NlmUniqueID>7802443</NlmUniqueID>
<ISSNLinking>0161-6420</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D008768">Methylmethacrylates</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011126">Polypropylenes</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002924">Ciliary Body</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005123">Eye</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007498">Iris</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007903">Lens Capsule, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007910">Lenses, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000009">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008722">Methods</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008768">Methylmethacrylates</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011126">Polypropylenes</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1987</Year>
<Month>2</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1987</Year>
<Month>2</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1987</Year>
<Month>2</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">3574878</ArticleId>
<ArticleId IdType="pii">S0161-6420(87)33485-2</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002317 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002317 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:3574878
   |texte=   Location and composition of haptics of posterior chamber intraocular lenses. Histopathologic study of postmortem eyes.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:3574878" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024