Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Anterior chamber lenses. Part I: Complications and pathology and a review of designs.

Identifieur interne : 002315 ( PubMed/Corpus ); précédent : 002314; suivant : 002316

Anterior chamber lenses. Part I: Complications and pathology and a review of designs.

Auteurs : D J Apple ; R N Brems ; R B Park ; D K Norman ; S O Hansen ; M R Tetz ; S C Richards ; S D Letchinger

Source :

RBID : pubmed:3572772

English descriptors

Abstract

Clinicopathologic data to assist ophthalmologists in choosing a safe and efficacious anterior chamber intraocular lens (IOL) are rapidly becoming available. Two important factors that have led to an increased success rate with some anterior chamber IOL styles are (1) attention to lens design and (2) attention to modern manufacturing and lens finishing techniques. We now know much more about how to achieve appropriate lens flexibility, which decreases the need for perfect sizing. Increased attention has been given to the anterior-posterior vaulting characteristics of IOLs. This has reduced the incidence of various complications such as the intermittent touch syndrome and the uveal chafing syndrome. We recognize several design flaws in some lens styles. For example, there is now a considerable decrease in the number of small-diameter, round-looped anterior chamber IOLs being implanted, particularly those with a closed-loop configuration. Several problems have been and continue to be caused by some poorly manufactured anterior chamber lenses with sharp optic and haptic edges. Technology to assure smooth lens finishing and polishing is available and readily accessible to all manufacturers. Defective lenses should soon be a thing of the past.

PubMed: 3572772

Links to Exploration step

pubmed:3572772

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Anterior chamber lenses. Part I: Complications and pathology and a review of designs.</title>
<author>
<name sortKey="Apple, D J" sort="Apple, D J" uniqKey="Apple D" first="D J" last="Apple">D J Apple</name>
</author>
<author>
<name sortKey="Brems, R N" sort="Brems, R N" uniqKey="Brems R" first="R N" last="Brems">R N Brems</name>
</author>
<author>
<name sortKey="Park, R B" sort="Park, R B" uniqKey="Park R" first="R B" last="Park">R B Park</name>
</author>
<author>
<name sortKey="Norman, D K" sort="Norman, D K" uniqKey="Norman D" first="D K" last="Norman">D K Norman</name>
</author>
<author>
<name sortKey="Hansen, S O" sort="Hansen, S O" uniqKey="Hansen S" first="S O" last="Hansen">S O Hansen</name>
</author>
<author>
<name sortKey="Tetz, M R" sort="Tetz, M R" uniqKey="Tetz M" first="M R" last="Tetz">M R Tetz</name>
</author>
<author>
<name sortKey="Richards, S C" sort="Richards, S C" uniqKey="Richards S" first="S C" last="Richards">S C Richards</name>
</author>
<author>
<name sortKey="Letchinger, S D" sort="Letchinger, S D" uniqKey="Letchinger S" first="S D" last="Letchinger">S D Letchinger</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1987">1987</date>
<idno type="RBID">pubmed:3572772</idno>
<idno type="pmid">3572772</idno>
<idno type="wicri:Area/PubMed/Corpus">002315</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Anterior chamber lenses. Part I: Complications and pathology and a review of designs.</title>
<author>
<name sortKey="Apple, D J" sort="Apple, D J" uniqKey="Apple D" first="D J" last="Apple">D J Apple</name>
</author>
<author>
<name sortKey="Brems, R N" sort="Brems, R N" uniqKey="Brems R" first="R N" last="Brems">R N Brems</name>
</author>
<author>
<name sortKey="Park, R B" sort="Park, R B" uniqKey="Park R" first="R B" last="Park">R B Park</name>
</author>
<author>
<name sortKey="Norman, D K" sort="Norman, D K" uniqKey="Norman D" first="D K" last="Norman">D K Norman</name>
</author>
<author>
<name sortKey="Hansen, S O" sort="Hansen, S O" uniqKey="Hansen S" first="S O" last="Hansen">S O Hansen</name>
</author>
<author>
<name sortKey="Tetz, M R" sort="Tetz, M R" uniqKey="Tetz M" first="M R" last="Tetz">M R Tetz</name>
</author>
<author>
<name sortKey="Richards, S C" sort="Richards, S C" uniqKey="Richards S" first="S C" last="Richards">S C Richards</name>
</author>
<author>
<name sortKey="Letchinger, S D" sort="Letchinger, S D" uniqKey="Letchinger S" first="S D" last="Letchinger">S D Letchinger</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="1987" type="published">1987</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Anterior Chamber</term>
<term>Glaucoma (etiology)</term>
<term>Humans</term>
<term>Hyphema (etiology)</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Macular Edema (etiology)</term>
<term>Prosthesis Design</term>
<term>Syndrome</term>
<term>Uveitis (etiology)</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Glaucoma</term>
<term>Hyphema</term>
<term>Macular Edema</term>
<term>Uveitis</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Anterior Chamber</term>
<term>Humans</term>
<term>Prosthesis Design</term>
<term>Syndrome</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Clinicopathologic data to assist ophthalmologists in choosing a safe and efficacious anterior chamber intraocular lens (IOL) are rapidly becoming available. Two important factors that have led to an increased success rate with some anterior chamber IOL styles are (1) attention to lens design and (2) attention to modern manufacturing and lens finishing techniques. We now know much more about how to achieve appropriate lens flexibility, which decreases the need for perfect sizing. Increased attention has been given to the anterior-posterior vaulting characteristics of IOLs. This has reduced the incidence of various complications such as the intermittent touch syndrome and the uveal chafing syndrome. We recognize several design flaws in some lens styles. For example, there is now a considerable decrease in the number of small-diameter, round-looped anterior chamber IOLs being implanted, particularly those with a closed-loop configuration. Several problems have been and continue to be caused by some poorly manufactured anterior chamber lenses with sharp optic and haptic edges. Technology to assure smooth lens finishing and polishing is available and readily accessible to all manufacturers. Defective lenses should soon be a thing of the past.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">3572772</PMID>
<DateCreated>
<Year>1987</Year>
<Month>05</Month>
<Day>26</Day>
</DateCreated>
<DateCompleted>
<Year>1987</Year>
<Month>05</Month>
<Day>26</Day>
</DateCompleted>
<DateRevised>
<Year>2007</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>13</Volume>
<Issue>2</Issue>
<PubDate>
<Year>1987</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Anterior chamber lenses. Part I: Complications and pathology and a review of designs.</ArticleTitle>
<Pagination>
<MedlinePgn>157-74</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Clinicopathologic data to assist ophthalmologists in choosing a safe and efficacious anterior chamber intraocular lens (IOL) are rapidly becoming available. Two important factors that have led to an increased success rate with some anterior chamber IOL styles are (1) attention to lens design and (2) attention to modern manufacturing and lens finishing techniques. We now know much more about how to achieve appropriate lens flexibility, which decreases the need for perfect sizing. Increased attention has been given to the anterior-posterior vaulting characteristics of IOLs. This has reduced the incidence of various complications such as the intermittent touch syndrome and the uveal chafing syndrome. We recognize several design flaws in some lens styles. For example, there is now a considerable decrease in the number of small-diameter, round-looped anterior chamber IOLs being implanted, particularly those with a closed-loop configuration. Several problems have been and continue to be caused by some poorly manufactured anterior chamber lenses with sharp optic and haptic edges. Technology to assure smooth lens finishing and polishing is available and readily accessible to all manufacturers. Defective lenses should soon be a thing of the past.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Apple</LastName>
<ForeName>D J</ForeName>
<Initials>DJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Brems</LastName>
<ForeName>R N</ForeName>
<Initials>RN</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Park</LastName>
<ForeName>R B</ForeName>
<Initials>RB</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Norman</LastName>
<ForeName>D K</ForeName>
<Initials>DK</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Hansen</LastName>
<ForeName>S O</ForeName>
<Initials>SO</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Tetz</LastName>
<ForeName>M R</ForeName>
<Initials>MR</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Richards</LastName>
<ForeName>S C</ForeName>
<Initials>SC</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Letchinger</LastName>
<ForeName>S D</ForeName>
<Initials>SD</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D000867">Anterior Chamber</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005901">Glaucoma</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006988">Hyphema</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007910">Lenses, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000009">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008269">Macular Edema</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013577">Syndrome</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014605">Uveitis</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000209">etiology</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1987</Year>
<Month>3</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1987</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1987</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">3572772</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002315 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002315 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:3572772
   |texte=   Anterior chamber lenses. Part I: Complications and pathology and a review of designs.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:3572772" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024