Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

[Light phenomena in the dislocation of artificial lenses in a model trial].

Identifieur interne : 002305 ( PubMed/Corpus ); précédent : 002304; suivant : 002306

[Light phenomena in the dislocation of artificial lenses in a model trial].

Auteurs : W. Aust

Source :

RBID : pubmed:3657020

English descriptors

Abstract

Light phenomena evoked by a Kratz elliptical posterior chamber lens, a Mark Choyce IX anterior chamber lens, and a four-loop Binkhorst anterior chamber lens were investigated in a model with pupils of various sizes. Besides monocular diplopia, the edge of the lens produces scattered light phenomena which vary according to the type of lens as well as the size of the pupil. It makes little difference whether the beam of light strikes the surface of the lens perpendicularly or at an angle of 30 degrees. Of the three lenses tested, the four-loop Binkhorst lens caused the most intense scattered light, due to the fixation of its haptic near its center.

DOI: 10.1055/s-2008-1050471
PubMed: 3657020

Links to Exploration step

pubmed:3657020

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Light phenomena in the dislocation of artificial lenses in a model trial].</title>
<author>
<name sortKey="Aust, W" sort="Aust, W" uniqKey="Aust W" first="W" last="Aust">W. Aust</name>
<affiliation>
<nlm:affiliation>Augenklinik des Lehrkrankenhauses Kassel.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1987">1987</date>
<idno type="RBID">pubmed:3657020</idno>
<idno type="pmid">3657020</idno>
<idno type="doi">10.1055/s-2008-1050471</idno>
<idno type="wicri:Area/PubMed/Corpus">002305</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Light phenomena in the dislocation of artificial lenses in a model trial].</title>
<author>
<name sortKey="Aust, W" sort="Aust, W" uniqKey="Aust W" first="W" last="Aust">W. Aust</name>
<affiliation>
<nlm:affiliation>Augenklinik des Lehrkrankenhauses Kassel.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Klinische Monatsblätter für Augenheilkunde</title>
<idno type="ISSN">0023-2165</idno>
<imprint>
<date when="1987" type="published">1987</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Diplopia (etiology)</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Light</term>
<term>Postoperative Complications (etiology)</term>
<term>Prosthesis Design</term>
<term>Scattering, Radiation</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Diplopia</term>
<term>Postoperative Complications</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Light</term>
<term>Prosthesis Design</term>
<term>Scattering, Radiation</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Light phenomena evoked by a Kratz elliptical posterior chamber lens, a Mark Choyce IX anterior chamber lens, and a four-loop Binkhorst anterior chamber lens were investigated in a model with pupils of various sizes. Besides monocular diplopia, the edge of the lens produces scattered light phenomena which vary according to the type of lens as well as the size of the pupil. It makes little difference whether the beam of light strikes the surface of the lens perpendicularly or at an angle of 30 degrees. Of the three lenses tested, the four-loop Binkhorst lens caused the most intense scattered light, due to the fixation of its haptic near its center.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">3657020</PMID>
<DateCreated>
<Year>1987</Year>
<Month>10</Month>
<Day>30</Day>
</DateCreated>
<DateCompleted>
<Year>1987</Year>
<Month>10</Month>
<Day>30</Day>
</DateCompleted>
<DateRevised>
<Year>2009</Year>
<Month>11</Month>
<Day>11</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0023-2165</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>191</Volume>
<Issue>1</Issue>
<PubDate>
<Year>1987</Year>
<Month>Jul</Month>
</PubDate>
</JournalIssue>
<Title>Klinische Monatsblätter für Augenheilkunde</Title>
<ISOAbbreviation>Klin Monbl Augenheilkd</ISOAbbreviation>
</Journal>
<ArticleTitle>[Light phenomena in the dislocation of artificial lenses in a model trial].</ArticleTitle>
<Pagination>
<MedlinePgn>78-80</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Light phenomena evoked by a Kratz elliptical posterior chamber lens, a Mark Choyce IX anterior chamber lens, and a four-loop Binkhorst anterior chamber lens were investigated in a model with pupils of various sizes. Besides monocular diplopia, the edge of the lens produces scattered light phenomena which vary according to the type of lens as well as the size of the pupil. It makes little difference whether the beam of light strikes the surface of the lens perpendicularly or at an angle of 30 degrees. Of the three lenses tested, the four-loop Binkhorst lens caused the most intense scattered light, due to the fixation of its haptic near its center.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Aust</LastName>
<ForeName>W</ForeName>
<Initials>W</Initials>
<AffiliationInfo>
<Affiliation>Augenklinik des Lehrkrankenhauses Kassel.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>ger</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Lichtphänòmene bei Luxation von Kunststofflinsen im Modellversuch.</VernacularTitle>
</Article>
<MedlineJournalInfo>
<Country>GERMANY, WEST</Country>
<MedlineTA>Klin Monbl Augenheilkd</MedlineTA>
<NlmUniqueID>0014133</NlmUniqueID>
<ISSNLinking>0023-2165</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D004172">Diplopia</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D008027">Light</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011183">Postoperative Complications</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D012542">Scattering, Radiation</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1987</Year>
<Month>7</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1987</Year>
<Month>7</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1987</Year>
<Month>7</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">3657020</ArticleId>
<ArticleId IdType="doi">10.1055/s-2008-1050471</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002305 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002305 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:3657020
   |texte=   [Light phenomena in the dislocation of artificial lenses in a model trial].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:3657020" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024