Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Role of positioning holes in intraocular lens glare.

Identifieur interne : 002253 ( PubMed/Corpus ); précédent : 002252; suivant : 002254

Role of positioning holes in intraocular lens glare.

Auteurs : K. Ohara ; K. Abe

Source :

RBID : pubmed:2614707

English descriptors

Abstract

We performed laboratory studies to determine the role of positioning holes in posterior chamber intraocular lens glare. Several areas of the lens optic were illuminated independently, and the scattering light off the lens was photographed. A conventional lathe-cut lens with four positioning holes on the optic produced the most intense light scattering. Scattering off nonilluminated areas was apparent, and it was suggested that the presence of positioning holes on the optic might contribute to the scattering. Optically complex areas including a hole, optic edge, a loop insertion, and optic-haptic junction produced the scattering in all lenses of various designs. An internal reflex inside the optic may occur, and complex or irregular structures in the optic may be a source of light scattering and some intraocular lens glare.

PubMed: 2614707

Links to Exploration step

pubmed:2614707

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Role of positioning holes in intraocular lens glare.</title>
<author>
<name sortKey="Ohara, K" sort="Ohara, K" uniqKey="Ohara K" first="K" last="Ohara">K. Ohara</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, Jichi Medical School, Tochigi-ken, Japan.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Abe, K" sort="Abe, K" uniqKey="Abe K" first="K" last="Abe">K. Abe</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1989">1989</date>
<idno type="RBID">pubmed:2614707</idno>
<idno type="pmid">2614707</idno>
<idno type="wicri:Area/PubMed/Corpus">002253</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Role of positioning holes in intraocular lens glare.</title>
<author>
<name sortKey="Ohara, K" sort="Ohara, K" uniqKey="Ohara K" first="K" last="Ohara">K. Ohara</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, Jichi Medical School, Tochigi-ken, Japan.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Abe, K" sort="Abe, K" uniqKey="Abe K" first="K" last="Abe">K. Abe</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="1989" type="published">1989</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Lenses, Intraocular</term>
<term>Light</term>
<term>Optics and Photonics</term>
<term>Photography</term>
<term>Prosthesis Design</term>
<term>Scattering, Radiation</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Lenses, Intraocular</term>
<term>Light</term>
<term>Optics and Photonics</term>
<term>Photography</term>
<term>Prosthesis Design</term>
<term>Scattering, Radiation</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We performed laboratory studies to determine the role of positioning holes in posterior chamber intraocular lens glare. Several areas of the lens optic were illuminated independently, and the scattering light off the lens was photographed. A conventional lathe-cut lens with four positioning holes on the optic produced the most intense light scattering. Scattering off nonilluminated areas was apparent, and it was suggested that the presence of positioning holes on the optic might contribute to the scattering. Optically complex areas including a hole, optic edge, a loop insertion, and optic-haptic junction produced the scattering in all lenses of various designs. An internal reflex inside the optic may occur, and complex or irregular structures in the optic may be a source of light scattering and some intraocular lens glare.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">2614707</PMID>
<DateCreated>
<Year>1990</Year>
<Month>03</Month>
<Day>09</Day>
</DateCreated>
<DateCompleted>
<Year>1990</Year>
<Month>03</Month>
<Day>09</Day>
</DateCompleted>
<DateRevised>
<Year>2008</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>15</Volume>
<Issue>6</Issue>
<PubDate>
<Year>1989</Year>
<Month>Nov</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Role of positioning holes in intraocular lens glare.</ArticleTitle>
<Pagination>
<MedlinePgn>647-53</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>We performed laboratory studies to determine the role of positioning holes in posterior chamber intraocular lens glare. Several areas of the lens optic were illuminated independently, and the scattering light off the lens was photographed. A conventional lathe-cut lens with four positioning holes on the optic produced the most intense light scattering. Scattering off nonilluminated areas was apparent, and it was suggested that the presence of positioning holes on the optic might contribute to the scattering. Optically complex areas including a hole, optic edge, a loop insertion, and optic-haptic junction produced the scattering in all lenses of various designs. An internal reflex inside the optic may occur, and complex or irregular structures in the optic may be a source of light scattering and some intraocular lens glare.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Ohara</LastName>
<ForeName>K</ForeName>
<Initials>K</Initials>
<AffiliationInfo>
<Affiliation>Department of Ophthalmology, Jichi Medical School, Tochigi-ken, Japan.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Abe</LastName>
<ForeName>K</ForeName>
<Initials>K</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008027">Light</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D055095">Optics and Photonics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D010781">Photography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D012542">Scattering, Radiation</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1989</Year>
<Month>11</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1989</Year>
<Month>11</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1989</Year>
<Month>11</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">2614707</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002253 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002253 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:2614707
   |texte=   Role of positioning holes in intraocular lens glare.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:2614707" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024