A technique for knotting a suture around the loops of a dislocated intraocular lens, within the eye, for fixation in the ciliary sulcus.
Identifieur interne : 002151 ( PubMed/Corpus ); précédent : 002150; suivant : 002152A technique for knotting a suture around the loops of a dislocated intraocular lens, within the eye, for fixation in the ciliary sulcus.
Auteurs : E A Navia-AraySource :
- Ophthalmic surgery [ 0022-023X ] ; 1993.
English descriptors
- KwdEn :
- MESH :
- chemical : Polypropylenes.
- surgery : Ciliary Body.
- Adult, Aged, Cataract Extraction, Humans, Lenses, Intraocular, Male, Prosthesis Failure, Reoperation, Suture Techniques, Visual Acuity.
Abstract
I describe a new, simpler, technique for attaching a suture to the haptic of a dislocated posterior chamber lens implant. A 10-0 polypropylene suture is used, doubly armed with straight needles. This technique has been used successfully in five cases.
PubMed: 8259252
Links to Exploration step
pubmed:8259252Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">A technique for knotting a suture around the loops of a dislocated intraocular lens, within the eye, for fixation in the ciliary sulcus.</title>
<author><name sortKey="Navia Aray, E A" sort="Navia Aray, E A" uniqKey="Navia Aray E" first="E A" last="Navia-Aray">E A Navia-Aray</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, Guayaquil City Hospital, Ecuador.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1993">1993</date>
<idno type="RBID">pubmed:8259252</idno>
<idno type="pmid">8259252</idno>
<idno type="wicri:Area/PubMed/Corpus">002151</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">A technique for knotting a suture around the loops of a dislocated intraocular lens, within the eye, for fixation in the ciliary sulcus.</title>
<author><name sortKey="Navia Aray, E A" sort="Navia Aray, E A" uniqKey="Navia Aray E" first="E A" last="Navia-Aray">E A Navia-Aray</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, Guayaquil City Hospital, Ecuador.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series><title level="j">Ophthalmic surgery</title>
<idno type="ISSN">0022-023X</idno>
<imprint><date when="1993" type="published">1993</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adult</term>
<term>Aged</term>
<term>Cataract Extraction</term>
<term>Ciliary Body (surgery)</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Polypropylenes</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Suture Techniques</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Polypropylenes</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Ciliary Body</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adult</term>
<term>Aged</term>
<term>Cataract Extraction</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Suture Techniques</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">I describe a new, simpler, technique for attaching a suture to the haptic of a dislocated posterior chamber lens implant. A 10-0 polypropylene suture is used, doubly armed with straight needles. This technique has been used successfully in five cases.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">8259252</PMID>
<DateCreated><Year>1994</Year>
<Month>01</Month>
<Day>19</Day>
</DateCreated>
<DateCompleted><Year>1994</Year>
<Month>01</Month>
<Day>19</Day>
</DateCompleted>
<DateRevised><Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0022-023X</ISSN>
<JournalIssue CitedMedium="Print"><Volume>24</Volume>
<Issue>10</Issue>
<PubDate><Year>1993</Year>
<Month>Oct</Month>
</PubDate>
</JournalIssue>
<Title>Ophthalmic surgery</Title>
<ISOAbbreviation>Ophthalmic Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>A technique for knotting a suture around the loops of a dislocated intraocular lens, within the eye, for fixation in the ciliary sulcus.</ArticleTitle>
<Pagination><MedlinePgn>702-7</MedlinePgn>
</Pagination>
<Abstract><AbstractText>I describe a new, simpler, technique for attaching a suture to the haptic of a dislocated posterior chamber lens implant. A 10-0 polypropylene suture is used, doubly armed with straight needles. This technique has been used successfully in five cases.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Navia-Aray</LastName>
<ForeName>E A</ForeName>
<Initials>EA</Initials>
<AffiliationInfo><Affiliation>Department of Ophthalmology, Guayaquil City Hospital, Ecuador.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>UNITED STATES</Country>
<MedlineTA>Ophthalmic Surg</MedlineTA>
<NlmUniqueID>0241035</NlmUniqueID>
<ISSNLinking>0022-023X</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011126">Polypropylenes</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D002387">Cataract Extraction</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D002924">Ciliary Body</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011126">Polypropylenes</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011475">Prosthesis Failure</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012086">Reoperation</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D013536">Suture Techniques</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>1993</Year>
<Month>10</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>1993</Year>
<Month>10</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>1993</Year>
<Month>10</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">8259252</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002151 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002151 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:8259252 |texte= A technique for knotting a suture around the loops of a dislocated intraocular lens, within the eye, for fixation in the ciliary sulcus. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:8259252" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |