[Ultrasound biomicroscopy for localization of artificial lens haptics after trans-scleral suture fixation].
Identifieur interne : 002039 ( PubMed/Corpus ); précédent : 002038; suivant : 002040[Ultrasound biomicroscopy for localization of artificial lens haptics after trans-scleral suture fixation].
Auteurs : A. Steiner ; U H Steinhorst ; M. Steiner ; M. Theischen ; R. WinterSource :
- Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft [ 0941-293X ] ; 1997.
English descriptors
- KwdEn :
- MESH :
- chemical : Methylmethacrylates.
- instrumentation : Microsurgery, Ultrasonography.
- surgery : Sclera.
- ultrasonography : Postoperative Complications.
- Follow-Up Studies, Humans, Lenses, Intraocular, Ophthalmoscopes, Suture Techniques, Treatment Outcome.
Abstract
Correct positioning of transscleral haptics for sulcus fixation of IOL haptics may be difficult due to lack of visual control by the surgeon. We determined the haptic sites in eyes which underwent secondary IOL implantation with transscleral suturing using ultrasound biomicroscopy (UBM) (Humphrey Instruments, Inc., San Leandro, CA, USA). Eighteen eyes of 17 patients were included in the study. The follow-up time ranged from 1 to 36 months (mean: 7 months). The positions of 36 IOL-haptics were documented by UBM examination. Twelve haptics (33%) were found in the sulcus, whereas 18 haptics (50%) were located posteriorly to the sulcus. Six haptics (17%) were identified anteriorly to the sulcus. There were no complications resulting from dislocation. In one of the eyes, suture infection occurred requiring surgical revision and antibiotic therapy.
PubMed: 9132128
Links to Exploration step
pubmed:9132128Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">[Ultrasound biomicroscopy for localization of artificial lens haptics after trans-scleral suture fixation].</title>
<author><name sortKey="Steiner, A" sort="Steiner, A" uniqKey="Steiner A" first="A" last="Steiner">A. Steiner</name>
<affiliation><nlm:affiliation>Augenklinik, Medizinische Hochschule Hannover.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Steinhorst, U H" sort="Steinhorst, U H" uniqKey="Steinhorst U" first="U H" last="Steinhorst">U H Steinhorst</name>
</author>
<author><name sortKey="Steiner, M" sort="Steiner, M" uniqKey="Steiner M" first="M" last="Steiner">M. Steiner</name>
</author>
<author><name sortKey="Theischen, M" sort="Theischen, M" uniqKey="Theischen M" first="M" last="Theischen">M. Theischen</name>
</author>
<author><name sortKey="Winter, R" sort="Winter, R" uniqKey="Winter R" first="R" last="Winter">R. Winter</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1997">1997</date>
<idno type="RBID">pubmed:9132128</idno>
<idno type="pmid">9132128</idno>
<idno type="wicri:Area/PubMed/Corpus">002039</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">[Ultrasound biomicroscopy for localization of artificial lens haptics after trans-scleral suture fixation].</title>
<author><name sortKey="Steiner, A" sort="Steiner, A" uniqKey="Steiner A" first="A" last="Steiner">A. Steiner</name>
<affiliation><nlm:affiliation>Augenklinik, Medizinische Hochschule Hannover.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Steinhorst, U H" sort="Steinhorst, U H" uniqKey="Steinhorst U" first="U H" last="Steinhorst">U H Steinhorst</name>
</author>
<author><name sortKey="Steiner, M" sort="Steiner, M" uniqKey="Steiner M" first="M" last="Steiner">M. Steiner</name>
</author>
<author><name sortKey="Theischen, M" sort="Theischen, M" uniqKey="Theischen M" first="M" last="Theischen">M. Theischen</name>
</author>
<author><name sortKey="Winter, R" sort="Winter, R" uniqKey="Winter R" first="R" last="Winter">R. Winter</name>
</author>
</analytic>
<series><title level="j">Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</title>
<idno type="ISSN">0941-293X</idno>
<imprint><date when="1997" type="published">1997</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Methylmethacrylates</term>
<term>Microsurgery (instrumentation)</term>
<term>Ophthalmoscopes</term>
<term>Postoperative Complications (ultrasonography)</term>
<term>Sclera (surgery)</term>
<term>Suture Techniques</term>
<term>Treatment Outcome</term>
<term>Ultrasonography (instrumentation)</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Methylmethacrylates</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Microsurgery</term>
<term>Ultrasonography</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Sclera</term>
</keywords>
<keywords scheme="MESH" qualifier="ultrasonography" xml:lang="en"><term>Postoperative Complications</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Ophthalmoscopes</term>
<term>Suture Techniques</term>
<term>Treatment Outcome</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Correct positioning of transscleral haptics for sulcus fixation of IOL haptics may be difficult due to lack of visual control by the surgeon. We determined the haptic sites in eyes which underwent secondary IOL implantation with transscleral suturing using ultrasound biomicroscopy (UBM) (Humphrey Instruments, Inc., San Leandro, CA, USA). Eighteen eyes of 17 patients were included in the study. The follow-up time ranged from 1 to 36 months (mean: 7 months). The positions of 36 IOL-haptics were documented by UBM examination. Twelve haptics (33%) were found in the sulcus, whereas 18 haptics (50%) were located posteriorly to the sulcus. Six haptics (17%) were identified anteriorly to the sulcus. There were no complications resulting from dislocation. In one of the eyes, suture infection occurred requiring surgical revision and antibiotic therapy.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">9132128</PMID>
<DateCreated><Year>1997</Year>
<Month>04</Month>
<Day>30</Day>
</DateCreated>
<DateCompleted><Year>1997</Year>
<Month>04</Month>
<Day>30</Day>
</DateCompleted>
<DateRevised><Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0941-293X</ISSN>
<JournalIssue CitedMedium="Print"><Volume>94</Volume>
<Issue>1</Issue>
<PubDate><Year>1997</Year>
<Month>Jan</Month>
</PubDate>
</JournalIssue>
<Title>Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</Title>
<ISOAbbreviation>Ophthalmologe</ISOAbbreviation>
</Journal>
<ArticleTitle>[Ultrasound biomicroscopy for localization of artificial lens haptics after trans-scleral suture fixation].</ArticleTitle>
<Pagination><MedlinePgn>41-4</MedlinePgn>
</Pagination>
<Abstract><AbstractText>Correct positioning of transscleral haptics for sulcus fixation of IOL haptics may be difficult due to lack of visual control by the surgeon. We determined the haptic sites in eyes which underwent secondary IOL implantation with transscleral suturing using ultrasound biomicroscopy (UBM) (Humphrey Instruments, Inc., San Leandro, CA, USA). Eighteen eyes of 17 patients were included in the study. The follow-up time ranged from 1 to 36 months (mean: 7 months). The positions of 36 IOL-haptics were documented by UBM examination. Twelve haptics (33%) were found in the sulcus, whereas 18 haptics (50%) were located posteriorly to the sulcus. Six haptics (17%) were identified anteriorly to the sulcus. There were no complications resulting from dislocation. In one of the eyes, suture infection occurred requiring surgical revision and antibiotic therapy.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Steiner</LastName>
<ForeName>A</ForeName>
<Initials>A</Initials>
<AffiliationInfo><Affiliation>Augenklinik, Medizinische Hochschule Hannover.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Steinhorst</LastName>
<ForeName>U H</ForeName>
<Initials>UH</Initials>
</Author>
<Author ValidYN="Y"><LastName>Steiner</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y"><LastName>Theischen</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y"><LastName>Winter</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
</Author>
</AuthorList>
<Language>ger</Language>
<PublicationTypeList><PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Ultraschallbiomikroskopie (UBM) zur Lokalisation der Kunstlinsenhaptik nach transskleraler Nahtfixation.</VernacularTitle>
</Article>
<MedlineJournalInfo><Country>GERMANY</Country>
<MedlineTA>Ophthalmologe</MedlineTA>
<NlmUniqueID>9206148</NlmUniqueID>
<ISSNLinking>0941-293X</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D008768">Methylmethacrylates</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D005500">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D008768">Methylmethacrylates</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008866">Microsurgery</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D019721">Ophthalmoscopes</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011183">Postoperative Complications</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000736">ultrasonography</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012590">Sclera</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D013536">Suture Techniques</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D016896">Treatment Outcome</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014463">Ultrasonography</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>1997</Year>
<Month>1</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>1997</Year>
<Month>1</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>1997</Year>
<Month>1</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">9132128</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002039 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002039 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:9132128 |texte= [Ultrasound biomicroscopy for localization of artificial lens haptics after trans-scleral suture fixation]. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:9132128" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |