ICTS, an interventional cardiology training system.

Identifieur interne : 001E17 ( PubMed/Corpus ); précédent : 001E16; suivant : 001E18

ICTS, an interventional cardiology training system.

Auteurs : S. Cotin ; S L Dawson ; D. Meglan ; D W Shaffer ; M A Ferrell ; R S Bardsley ; F M Morgan ; T. Nagano ; J. Nikom ; P. Sherman ; M T Walterman ; J. Wendlandt

Source :

RBID : pubmed:10977584

English descriptors

Abstract

In this article, we present an Interventional Cardiology Training System developed by the Medical Application Group at Mitsubishi Electric in collaboration with the Center for Innovative Minimally Invasive Therapy. The core of the ICTS is a computer simulation of interventional cardiology catheterization. This simulation integrates clinical expertise, research in learning, and technical innovations to create a realistic simulated environment. The goal of this training system is to augment the training of new cardiology fellows as well as to introduce cardiologists to new devices and procedures. To achieve this goal, both the technical components and the educational content of the ICTS bring new and unique features: a simulated fluoroscope, a physics model of a catheter, a haptic interface, a fluid flow simulation combined with a hemodynamic model and a learning system integrated in a user interface. The simulator is currently able to generate--in real-time--high quality x-ray images from a 3D anatomical model of the thorax, including a beating heart and animated lungs. The heart and lung motion is controlled by the hemodynamic model, which also computes blood pressure and EKG. The blood flow is then calculated according to the blood pressure and blood vessel characteristics. Any vascular tool, such as a catheter, guide wire or angioplasty balloon can be represented and accurately deformed by the flexible tool physics model. The haptics device controls the tool and provides appropriate feedback when contact with a vessel wall is detected. When the catheter is in place, a contrast agent can be injected into the coronary arteries; blood and contrast mixing is computed and a visual representation of the angiogram is displayed by the x-ray renderer. By bringing key advances in the area of medical simulation--with the real-time x-ray renderer for instance--and by integrating in a single system both high quality simulation and learning tools, the ICTS opens new perspectives for computer based training systems.

PubMed: 10977584

Links to Exploration step

pubmed:10977584

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">ICTS, an interventional cardiology training system.</title>
<author>
<name sortKey="Cotin, S" sort="Cotin, S" uniqKey="Cotin S" first="S" last="Cotin">S. Cotin</name>
<affiliation>
<nlm:affiliation>Virtual Presence, Inc., Boston, MA, USA.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Dawson, S L" sort="Dawson, S L" uniqKey="Dawson S" first="S L" last="Dawson">S L Dawson</name>
</author>
<author>
<name sortKey="Meglan, D" sort="Meglan, D" uniqKey="Meglan D" first="D" last="Meglan">D. Meglan</name>
</author>
<author>
<name sortKey="Shaffer, D W" sort="Shaffer, D W" uniqKey="Shaffer D" first="D W" last="Shaffer">D W Shaffer</name>
</author>
<author>
<name sortKey="Ferrell, M A" sort="Ferrell, M A" uniqKey="Ferrell M" first="M A" last="Ferrell">M A Ferrell</name>
</author>
<author>
<name sortKey="Bardsley, R S" sort="Bardsley, R S" uniqKey="Bardsley R" first="R S" last="Bardsley">R S Bardsley</name>
</author>
<author>
<name sortKey="Morgan, F M" sort="Morgan, F M" uniqKey="Morgan F" first="F M" last="Morgan">F M Morgan</name>
</author>
<author>
<name sortKey="Nagano, T" sort="Nagano, T" uniqKey="Nagano T" first="T" last="Nagano">T. Nagano</name>
</author>
<author>
<name sortKey="Nikom, J" sort="Nikom, J" uniqKey="Nikom J" first="J" last="Nikom">J. Nikom</name>
</author>
<author>
<name sortKey="Sherman, P" sort="Sherman, P" uniqKey="Sherman P" first="P" last="Sherman">P. Sherman</name>
</author>
<author>
<name sortKey="Walterman, M T" sort="Walterman, M T" uniqKey="Walterman M" first="M T" last="Walterman">M T Walterman</name>
</author>
<author>
<name sortKey="Wendlandt, J" sort="Wendlandt, J" uniqKey="Wendlandt J" first="J" last="Wendlandt">J. Wendlandt</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2000">2000</date>
<idno type="RBID">pubmed:10977584</idno>
<idno type="pmid">10977584</idno>
<idno type="wicri:Area/PubMed/Corpus">001E17</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">ICTS, an interventional cardiology training system.</title>
<author>
<name sortKey="Cotin, S" sort="Cotin, S" uniqKey="Cotin S" first="S" last="Cotin">S. Cotin</name>
<affiliation>
<nlm:affiliation>Virtual Presence, Inc., Boston, MA, USA.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Dawson, S L" sort="Dawson, S L" uniqKey="Dawson S" first="S L" last="Dawson">S L Dawson</name>
</author>
<author>
<name sortKey="Meglan, D" sort="Meglan, D" uniqKey="Meglan D" first="D" last="Meglan">D. Meglan</name>
</author>
<author>
<name sortKey="Shaffer, D W" sort="Shaffer, D W" uniqKey="Shaffer D" first="D W" last="Shaffer">D W Shaffer</name>
</author>
<author>
<name sortKey="Ferrell, M A" sort="Ferrell, M A" uniqKey="Ferrell M" first="M A" last="Ferrell">M A Ferrell</name>
</author>
<author>
<name sortKey="Bardsley, R S" sort="Bardsley, R S" uniqKey="Bardsley R" first="R S" last="Bardsley">R S Bardsley</name>
</author>
<author>
<name sortKey="Morgan, F M" sort="Morgan, F M" uniqKey="Morgan F" first="F M" last="Morgan">F M Morgan</name>
</author>
<author>
<name sortKey="Nagano, T" sort="Nagano, T" uniqKey="Nagano T" first="T" last="Nagano">T. Nagano</name>
</author>
<author>
<name sortKey="Nikom, J" sort="Nikom, J" uniqKey="Nikom J" first="J" last="Nikom">J. Nikom</name>
</author>
<author>
<name sortKey="Sherman, P" sort="Sherman, P" uniqKey="Sherman P" first="P" last="Sherman">P. Sherman</name>
</author>
<author>
<name sortKey="Walterman, M T" sort="Walterman, M T" uniqKey="Walterman M" first="M T" last="Walterman">M T Walterman</name>
</author>
<author>
<name sortKey="Wendlandt, J" sort="Wendlandt, J" uniqKey="Wendlandt J" first="J" last="Wendlandt">J. Wendlandt</name>
</author>
</analytic>
<series>
<title level="j">Studies in health technology and informatics</title>
<idno type="ISSN">0926-9630</idno>
<imprint>
<date when="2000" type="published">2000</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Angioplasty, Balloon, Coronary (instrumentation)</term>
<term>Cardiac Catheterization (instrumentation)</term>
<term>Cardiology (education)</term>
<term>Computer Simulation</term>
<term>Computer-Assisted Instruction (instrumentation)</term>
<term>Curriculum</term>
<term>Humans</term>
<term>Models, Cardiovascular</term>
<term>Software</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" qualifier="education" xml:lang="en">
<term>Cardiology</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Angioplasty, Balloon, Coronary</term>
<term>Cardiac Catheterization</term>
<term>Computer-Assisted Instruction</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Computer Simulation</term>
<term>Curriculum</term>
<term>Humans</term>
<term>Models, Cardiovascular</term>
<term>Software</term>
<term>User-Computer Interface</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">In this article, we present an Interventional Cardiology Training System developed by the Medical Application Group at Mitsubishi Electric in collaboration with the Center for Innovative Minimally Invasive Therapy. The core of the ICTS is a computer simulation of interventional cardiology catheterization. This simulation integrates clinical expertise, research in learning, and technical innovations to create a realistic simulated environment. The goal of this training system is to augment the training of new cardiology fellows as well as to introduce cardiologists to new devices and procedures. To achieve this goal, both the technical components and the educational content of the ICTS bring new and unique features: a simulated fluoroscope, a physics model of a catheter, a haptic interface, a fluid flow simulation combined with a hemodynamic model and a learning system integrated in a user interface. The simulator is currently able to generate--in real-time--high quality x-ray images from a 3D anatomical model of the thorax, including a beating heart and animated lungs. The heart and lung motion is controlled by the hemodynamic model, which also computes blood pressure and EKG. The blood flow is then calculated according to the blood pressure and blood vessel characteristics. Any vascular tool, such as a catheter, guide wire or angioplasty balloon can be represented and accurately deformed by the flexible tool physics model. The haptics device controls the tool and provides appropriate feedback when contact with a vessel wall is detected. When the catheter is in place, a contrast agent can be injected into the coronary arteries; blood and contrast mixing is computed and a visual representation of the angiogram is displayed by the x-ray renderer. By bringing key advances in the area of medical simulation--with the real-time x-ray renderer for instance--and by integrating in a single system both high quality simulation and learning tools, the ICTS opens new perspectives for computer based training systems.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">10977584</PMID>
<DateCreated>
<Year>2000</Year>
<Month>08</Month>
<Day>15</Day>
</DateCreated>
<DateCompleted>
<Year>2000</Year>
<Month>08</Month>
<Day>15</Day>
</DateCompleted>
<DateRevised>
<Year>2012</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0926-9630</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>70</Volume>
<PubDate>
<Year>2000</Year>
</PubDate>
</JournalIssue>
<Title>Studies in health technology and informatics</Title>
<ISOAbbreviation>Stud Health Technol Inform</ISOAbbreviation>
</Journal>
<ArticleTitle>ICTS, an interventional cardiology training system.</ArticleTitle>
<Pagination>
<MedlinePgn>59-65</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>In this article, we present an Interventional Cardiology Training System developed by the Medical Application Group at Mitsubishi Electric in collaboration with the Center for Innovative Minimally Invasive Therapy. The core of the ICTS is a computer simulation of interventional cardiology catheterization. This simulation integrates clinical expertise, research in learning, and technical innovations to create a realistic simulated environment. The goal of this training system is to augment the training of new cardiology fellows as well as to introduce cardiologists to new devices and procedures. To achieve this goal, both the technical components and the educational content of the ICTS bring new and unique features: a simulated fluoroscope, a physics model of a catheter, a haptic interface, a fluid flow simulation combined with a hemodynamic model and a learning system integrated in a user interface. The simulator is currently able to generate--in real-time--high quality x-ray images from a 3D anatomical model of the thorax, including a beating heart and animated lungs. The heart and lung motion is controlled by the hemodynamic model, which also computes blood pressure and EKG. The blood flow is then calculated according to the blood pressure and blood vessel characteristics. Any vascular tool, such as a catheter, guide wire or angioplasty balloon can be represented and accurately deformed by the flexible tool physics model. The haptics device controls the tool and provides appropriate feedback when contact with a vessel wall is detected. When the catheter is in place, a contrast agent can be injected into the coronary arteries; blood and contrast mixing is computed and a visual representation of the angiogram is displayed by the x-ray renderer. By bringing key advances in the area of medical simulation--with the real-time x-ray renderer for instance--and by integrating in a single system both high quality simulation and learning tools, the ICTS opens new perspectives for computer based training systems.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Cotin</LastName>
<ForeName>S</ForeName>
<Initials>S</Initials>
<AffiliationInfo>
<Affiliation>Virtual Presence, Inc., Boston, MA, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Dawson</LastName>
<ForeName>S L</ForeName>
<Initials>SL</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Meglan</LastName>
<ForeName>D</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Shaffer</LastName>
<ForeName>D W</ForeName>
<Initials>DW</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ferrell</LastName>
<ForeName>M A</ForeName>
<Initials>MA</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Bardsley</LastName>
<ForeName>R S</ForeName>
<Initials>RS</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Morgan</LastName>
<ForeName>F M</ForeName>
<Initials>FM</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Nagano</LastName>
<ForeName>T</ForeName>
<Initials>T</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Nikom</LastName>
<ForeName>J</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Sherman</LastName>
<ForeName>P</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Walterman</LastName>
<ForeName>M T</ForeName>
<Initials>MT</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Wendlandt</LastName>
<ForeName>J</ForeName>
<Initials>J</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>NETHERLANDS</Country>
<MedlineTA>Stud Health Technol Inform</MedlineTA>
<NlmUniqueID>9214582</NlmUniqueID>
<ISSNLinking>0926-9630</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>T</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D015906">Angioplasty, Balloon, Coronary</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006328">Cardiac Catheterization</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002309">Cardiology</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000193">education</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D003198">Computer Simulation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003194">Computer-Assisted Instruction</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003479">Curriculum</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D008955">Models, Cardiovascular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012984">Software</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014584">User-Computer Interface</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2000</Year>
<Month>9</Month>
<Day>8</Day>
<Hour>11</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2000</Year>
<Month>9</Month>
<Day>8</Day>
<Hour>11</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2000</Year>
<Month>9</Month>
<Day>8</Day>
<Hour>11</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">10977584</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001E17 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001E17 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:10977584
   |texte=   ICTS, an interventional cardiology training system.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:10977584" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024