Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Scleral fixation technique using 2 corneal tunnels for a dislocated intraocular lens.

Identifieur interne : 001E08 ( PubMed/Corpus ); précédent : 001E07; suivant : 001E09

Scleral fixation technique using 2 corneal tunnels for a dislocated intraocular lens.

Auteurs : H J Koh ; C Y Kim ; S J Lim ; O W Kwon

Source :

RBID : pubmed:11033388

English descriptors

Abstract

Several techniques are used to reposition dislocated intraocular lenses (IOLs). Most place a suture loop around the end of the haptic. However, in cases of a dislocated capsular bag containing the IOL, a dislocated IOL with a large haptic, or a miotic pupil, it is not easy to see the haptic ends to place the suture loop. We describe a scleral fixation technique that uses 2 corneal tunnels. A double-armed 10-0 polypropylene suture loop can be introduced through 1 corneal tunnel and placed around any accessible part of the haptic with the help of a bent 26 gauge needle. This modified technique is an easy and effective way to reposition the IOL.

PubMed: 11033388

Links to Exploration step

pubmed:11033388

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Scleral fixation technique using 2 corneal tunnels for a dislocated intraocular lens.</title>
<author>
<name sortKey="Koh, H J" sort="Koh, H J" uniqKey="Koh H" first="H J" last="Koh">H J Koh</name>
<affiliation>
<nlm:affiliation>Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea. hjkoh@yumc.yonsei.ac.kr</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Kim, C Y" sort="Kim, C Y" uniqKey="Kim C" first="C Y" last="Kim">C Y Kim</name>
</author>
<author>
<name sortKey="Lim, S J" sort="Lim, S J" uniqKey="Lim S" first="S J" last="Lim">S J Lim</name>
</author>
<author>
<name sortKey="Kwon, O W" sort="Kwon, O W" uniqKey="Kwon O" first="O W" last="Kwon">O W Kwon</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2000">2000</date>
<idno type="RBID">pubmed:11033388</idno>
<idno type="pmid">11033388</idno>
<idno type="wicri:Area/PubMed/Corpus">001E08</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Scleral fixation technique using 2 corneal tunnels for a dislocated intraocular lens.</title>
<author>
<name sortKey="Koh, H J" sort="Koh, H J" uniqKey="Koh H" first="H J" last="Koh">H J Koh</name>
<affiliation>
<nlm:affiliation>Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea. hjkoh@yumc.yonsei.ac.kr</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Kim, C Y" sort="Kim, C Y" uniqKey="Kim C" first="C Y" last="Kim">C Y Kim</name>
</author>
<author>
<name sortKey="Lim, S J" sort="Lim, S J" uniqKey="Lim S" first="S J" last="Lim">S J Lim</name>
</author>
<author>
<name sortKey="Kwon, O W" sort="Kwon, O W" uniqKey="Kwon O" first="O W" last="Kwon">O W Kwon</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2000" type="published">2000</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Biocompatible Materials</term>
<term>Cornea (surgery)</term>
<term>Foreign-Body Migration (surgery)</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Polypropylenes</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Sclera (surgery)</term>
<term>Suture Techniques (instrumentation)</term>
<term>Sutures</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Biocompatible Materials</term>
<term>Polypropylenes</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Suture Techniques</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Cornea</term>
<term>Foreign-Body Migration</term>
<term>Sclera</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Sutures</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Several techniques are used to reposition dislocated intraocular lenses (IOLs). Most place a suture loop around the end of the haptic. However, in cases of a dislocated capsular bag containing the IOL, a dislocated IOL with a large haptic, or a miotic pupil, it is not easy to see the haptic ends to place the suture loop. We describe a scleral fixation technique that uses 2 corneal tunnels. A double-armed 10-0 polypropylene suture loop can be introduced through 1 corneal tunnel and placed around any accessible part of the haptic with the help of a bent 26 gauge needle. This modified technique is an easy and effective way to reposition the IOL.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">11033388</PMID>
<DateCreated>
<Year>2000</Year>
<Month>11</Month>
<Day>02</Day>
</DateCreated>
<DateCompleted>
<Year>2000</Year>
<Month>11</Month>
<Day>21</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>26</Volume>
<Issue>10</Issue>
<PubDate>
<Year>2000</Year>
<Month>Oct</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Scleral fixation technique using 2 corneal tunnels for a dislocated intraocular lens.</ArticleTitle>
<Pagination>
<MedlinePgn>1439-41</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Several techniques are used to reposition dislocated intraocular lenses (IOLs). Most place a suture loop around the end of the haptic. However, in cases of a dislocated capsular bag containing the IOL, a dislocated IOL with a large haptic, or a miotic pupil, it is not easy to see the haptic ends to place the suture loop. We describe a scleral fixation technique that uses 2 corneal tunnels. A double-armed 10-0 polypropylene suture loop can be introduced through 1 corneal tunnel and placed around any accessible part of the haptic with the help of a bent 26 gauge needle. This modified technique is an easy and effective way to reposition the IOL.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Koh</LastName>
<ForeName>H J</ForeName>
<Initials>HJ</Initials>
<AffiliationInfo>
<Affiliation>Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea. hjkoh@yumc.yonsei.ac.kr</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Kim</LastName>
<ForeName>C Y</ForeName>
<Initials>CY</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Lim</LastName>
<ForeName>S J</ForeName>
<Initials>SJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Kwon</LastName>
<ForeName>O W</ForeName>
<Initials>OW</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D001672">Biocompatible Materials</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011126">Polypropylenes</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001672">Biocompatible Materials</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003315">Cornea</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005548">Foreign-Body Migration</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011126">Polypropylenes</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011475">Prosthesis Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012086">Reoperation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012590">Sclera</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D013536">Suture Techniques</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013537">Sutures</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2000</Year>
<Month>10</Month>
<Day>18</Day>
<Hour>11</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2001</Year>
<Month>2</Month>
<Day>28</Day>
<Hour>10</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2000</Year>
<Month>10</Month>
<Day>18</Day>
<Hour>11</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">11033388</ArticleId>
<ArticleId IdType="pii">S0886-3350(00)00477-6</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001E08 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001E08 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:11033388
   |texte=   Scleral fixation technique using 2 corneal tunnels for a dislocated intraocular lens.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:11033388" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024