Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Slipknot for scleral fixation of intraocular lenses.

Identifieur interne : 001D49 ( PubMed/Corpus ); précédent : 001D48; suivant : 001D50

Slipknot for scleral fixation of intraocular lenses.

Auteurs : S C Lee ; S H Tseng ; H C Cheng ; F K Chen

Source :

RBID : pubmed:11377892

English descriptors

Abstract

We describe a simple, quick technique to construct a slipknot that can be snared around the haptic of an intraocular lens (IOL) during transscleral fixation of a posterior chamber IOL or repositioning of a dislocated IOL. An in vitro experiment showed that the time required for the slipknot method was significantly less than that for the traditional triple-knot method. An additional advantage is that the slipknot technique can be performed by a single surgeon using standard ophthalmic instrumentation. In addition, the slipknot is as secure as a triple knot.

PubMed: 11377892

Links to Exploration step

pubmed:11377892

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Slipknot for scleral fixation of intraocular lenses.</title>
<author>
<name sortKey="Lee, S C" sort="Lee, S C" uniqKey="Lee S" first="S C" last="Lee">S C Lee</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, College of Medicine, National Cheng Kung University, Republic of, Tainan, Taiwan, Republic of China.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Tseng, S H" sort="Tseng, S H" uniqKey="Tseng S" first="S H" last="Tseng">S H Tseng</name>
</author>
<author>
<name sortKey="Cheng, H C" sort="Cheng, H C" uniqKey="Cheng H" first="H C" last="Cheng">H C Cheng</name>
</author>
<author>
<name sortKey="Chen, F K" sort="Chen, F K" uniqKey="Chen F" first="F K" last="Chen">F K Chen</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2001">2001</date>
<idno type="RBID">pubmed:11377892</idno>
<idno type="pmid">11377892</idno>
<idno type="wicri:Area/PubMed/Corpus">001D49</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Slipknot for scleral fixation of intraocular lenses.</title>
<author>
<name sortKey="Lee, S C" sort="Lee, S C" uniqKey="Lee S" first="S C" last="Lee">S C Lee</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, College of Medicine, National Cheng Kung University, Republic of, Tainan, Taiwan, Republic of China.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Tseng, S H" sort="Tseng, S H" uniqKey="Tseng S" first="S H" last="Tseng">S H Tseng</name>
</author>
<author>
<name sortKey="Cheng, H C" sort="Cheng, H C" uniqKey="Cheng H" first="H C" last="Cheng">H C Cheng</name>
</author>
<author>
<name sortKey="Chen, F K" sort="Chen, F K" uniqKey="Chen F" first="F K" last="Chen">F K Chen</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2001" type="published">2001</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Sclera (surgery)</term>
<term>Suture Techniques</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Sclera</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Suture Techniques</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We describe a simple, quick technique to construct a slipknot that can be snared around the haptic of an intraocular lens (IOL) during transscleral fixation of a posterior chamber IOL or repositioning of a dislocated IOL. An in vitro experiment showed that the time required for the slipknot method was significantly less than that for the traditional triple-knot method. An additional advantage is that the slipknot technique can be performed by a single surgeon using standard ophthalmic instrumentation. In addition, the slipknot is as secure as a triple knot.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">11377892</PMID>
<DateCreated>
<Year>2001</Year>
<Month>05</Month>
<Day>29</Day>
</DateCreated>
<DateCompleted>
<Year>2001</Year>
<Month>07</Month>
<Day>05</Day>
</DateCompleted>
<DateRevised>
<Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>27</Volume>
<Issue>5</Issue>
<PubDate>
<Year>2001</Year>
<Month>May</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Slipknot for scleral fixation of intraocular lenses.</ArticleTitle>
<Pagination>
<MedlinePgn>662-4</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>We describe a simple, quick technique to construct a slipknot that can be snared around the haptic of an intraocular lens (IOL) during transscleral fixation of a posterior chamber IOL or repositioning of a dislocated IOL. An in vitro experiment showed that the time required for the slipknot method was significantly less than that for the traditional triple-knot method. An additional advantage is that the slipknot technique can be performed by a single surgeon using standard ophthalmic instrumentation. In addition, the slipknot is as secure as a triple knot.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Lee</LastName>
<ForeName>S C</ForeName>
<Initials>SC</Initials>
<AffiliationInfo>
<Affiliation>Department of Ophthalmology, College of Medicine, National Cheng Kung University, Republic of, Tainan, Taiwan, Republic of China.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Tseng</LastName>
<ForeName>S H</ForeName>
<Initials>SH</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Cheng</LastName>
<ForeName>H C</ForeName>
<Initials>HC</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Chen</LastName>
<ForeName>F K</ForeName>
<Initials>FK</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012590">Sclera</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D013536">Suture Techniques</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2001</Year>
<Month>5</Month>
<Day>30</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2001</Year>
<Month>7</Month>
<Day>6</Day>
<Hour>10</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2001</Year>
<Month>5</Month>
<Day>30</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">11377892</ArticleId>
<ArticleId IdType="pii">S0886-3350(00)00708-2</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001D49 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001D49 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:11377892
   |texte=   Slipknot for scleral fixation of intraocular lenses.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:11377892" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024