Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

[Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem].

Identifieur interne : 001D26 ( PubMed/Corpus ); précédent : 001D25; suivant : 001D27

[Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem].

Auteurs : J M Schmidbauer ; L G Vargas ; D J Apple ; Q. Peng ; S N Arthur ; M. Escobar-Gomez ; A. Izak

Source :

RBID : pubmed:11573152

English descriptors

Abstract

The purpose of this study was to analyze any possible surgical reasons which may have had caused posterior capsule opacification in 3-piece silicone IOLs that had required Nd:YAG laser treatment. Special attention was given to 1) quality of cortical clean up, 2) type of haptic fixation, and 3) continuous curvilinear capsulorhexis (CCC) size and shape.

DOI: 10.1055/s-2001-17133
PubMed: 11573152

Links to Exploration step

pubmed:11573152

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem].</title>
<author>
<name sortKey="Schmidbauer, J M" sort="Schmidbauer, J M" uniqKey="Schmidbauer J" first="J M" last="Schmidbauer">J M Schmidbauer</name>
<affiliation>
<nlm:affiliation>Center for Research on Ocular Therapeutic and Biodevices; Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston 29425, South Carolina, USA. appledj@musc.edu</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vargas, L G" sort="Vargas, L G" uniqKey="Vargas L" first="L G" last="Vargas">L G Vargas</name>
</author>
<author>
<name sortKey="Apple, D J" sort="Apple, D J" uniqKey="Apple D" first="D J" last="Apple">D J Apple</name>
</author>
<author>
<name sortKey="Peng, Q" sort="Peng, Q" uniqKey="Peng Q" first="Q" last="Peng">Q. Peng</name>
</author>
<author>
<name sortKey="Arthur, S N" sort="Arthur, S N" uniqKey="Arthur S" first="S N" last="Arthur">S N Arthur</name>
</author>
<author>
<name sortKey="Escobar Gomez, M" sort="Escobar Gomez, M" uniqKey="Escobar Gomez M" first="M" last="Escobar-Gomez">M. Escobar-Gomez</name>
</author>
<author>
<name sortKey="Izak, A" sort="Izak, A" uniqKey="Izak A" first="A" last="Izak">A. Izak</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2001">2001</date>
<idno type="RBID">pubmed:11573152</idno>
<idno type="pmid">11573152</idno>
<idno type="doi">10.1055/s-2001-17133</idno>
<idno type="wicri:Area/PubMed/Corpus">001D26</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem].</title>
<author>
<name sortKey="Schmidbauer, J M" sort="Schmidbauer, J M" uniqKey="Schmidbauer J" first="J M" last="Schmidbauer">J M Schmidbauer</name>
<affiliation>
<nlm:affiliation>Center for Research on Ocular Therapeutic and Biodevices; Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston 29425, South Carolina, USA. appledj@musc.edu</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vargas, L G" sort="Vargas, L G" uniqKey="Vargas L" first="L G" last="Vargas">L G Vargas</name>
</author>
<author>
<name sortKey="Apple, D J" sort="Apple, D J" uniqKey="Apple D" first="D J" last="Apple">D J Apple</name>
</author>
<author>
<name sortKey="Peng, Q" sort="Peng, Q" uniqKey="Peng Q" first="Q" last="Peng">Q. Peng</name>
</author>
<author>
<name sortKey="Arthur, S N" sort="Arthur, S N" uniqKey="Arthur S" first="S N" last="Arthur">S N Arthur</name>
</author>
<author>
<name sortKey="Escobar Gomez, M" sort="Escobar Gomez, M" uniqKey="Escobar Gomez M" first="M" last="Escobar-Gomez">M. Escobar-Gomez</name>
</author>
<author>
<name sortKey="Izak, A" sort="Izak, A" uniqKey="Izak A" first="A" last="Izak">A. Izak</name>
</author>
</analytic>
<series>
<title level="j">Klinische Monatsblätter für Augenheilkunde</title>
<idno type="ISSN">0023-2165</idno>
<imprint>
<date when="2001" type="published">2001</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Cataract (pathology)</term>
<term>Humans</term>
<term>Laser Therapy</term>
<term>Lens Capsule, Crystalline (pathology)</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lenses, Intraocular</term>
<term>Polymethyl Methacrylate</term>
<term>Polypropylenes</term>
<term>Postoperative Complications (pathology)</term>
<term>Prosthesis Design</term>
<term>Pseudophakia (pathology)</term>
<term>Risk Factors</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Polymethyl Methacrylate</term>
<term>Polypropylenes</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Cataract</term>
<term>Lens Capsule, Crystalline</term>
<term>Postoperative Complications</term>
<term>Pseudophakia</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Laser Therapy</term>
<term>Lenses, Intraocular</term>
<term>Prosthesis Design</term>
<term>Risk Factors</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The purpose of this study was to analyze any possible surgical reasons which may have had caused posterior capsule opacification in 3-piece silicone IOLs that had required Nd:YAG laser treatment. Special attention was given to 1) quality of cortical clean up, 2) type of haptic fixation, and 3) continuous curvilinear capsulorhexis (CCC) size and shape.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">11573152</PMID>
<DateCreated>
<Year>2001</Year>
<Month>09</Month>
<Day>26</Day>
</DateCreated>
<DateCompleted>
<Year>2001</Year>
<Month>12</Month>
<Day>07</Day>
</DateCompleted>
<DateRevised>
<Year>2009</Year>
<Month>11</Month>
<Day>11</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0023-2165</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>218</Volume>
<Issue>8</Issue>
<PubDate>
<Year>2001</Year>
<Month>Aug</Month>
</PubDate>
</JournalIssue>
<Title>Klinische Monatsblätter für Augenheilkunde</Title>
<ISOAbbreviation>Klin Monbl Augenheilkd</ISOAbbreviation>
</Journal>
<ArticleTitle>[Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem].</ArticleTitle>
<Pagination>
<MedlinePgn>523-7</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">The purpose of this study was to analyze any possible surgical reasons which may have had caused posterior capsule opacification in 3-piece silicone IOLs that had required Nd:YAG laser treatment. Special attention was given to 1) quality of cortical clean up, 2) type of haptic fixation, and 3) continuous curvilinear capsulorhexis (CCC) size and shape.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Human eyes obtained post-mortem implanted with 3-piece silicone optic - PMMA haptic (SI 40 NB) and 3-piece silicone optic - Prolene haptic (SI 30 NB) designs IOLs, accessioned between January 1993 and December 2000 were evaluated by gross examination from behind under an operating microscope using the Miyake-Apple posterior photographic technique. The area and intensity of Soemmerring's ring and type of fixation was studied in 457 eyes. The mean diameter of the CCC and relation of the CCC edge to the optic rim were analyzed in 221 eyes.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">1) The amount of Soemmerring's ring formation was significantly larger in the group of IOLs requiring Nd:YAG capsulotomy in both the SI 40 NB and SI 30 NB design than in the IOLs without capsulotomies. 2) The percentage of not in-the-bag fixated IOLs in both the SI 40 NB and SI 30 NB design was larger in the "Nd:YAG groups", without being statistically significant. 3) The "Nd:YAG groups" showed a significant higher amount of non overlapping clock hours of the CCC edge in relation to the optic rim.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">1) The data confirm the clinical assumption that the incidence of PCO is correlated with the cortical clean up. 2) Our findings also support the clinical assumption, that poor IOL fixation increases the risk of PCO. 3) This study also verifies the relation of the CCC to PCO, namely a relatively small CCC covering the entire optic rim is best to reduce the Nd:YAG laser rate.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Schmidbauer</LastName>
<ForeName>J M</ForeName>
<Initials>JM</Initials>
<AffiliationInfo>
<Affiliation>Center for Research on Ocular Therapeutic and Biodevices; Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston 29425, South Carolina, USA. appledj@musc.edu</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Vargas</LastName>
<ForeName>L G</ForeName>
<Initials>LG</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Apple</LastName>
<ForeName>D J</ForeName>
<Initials>DJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Peng</LastName>
<ForeName>Q</ForeName>
<Initials>Q</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Arthur</LastName>
<ForeName>S N</ForeName>
<Initials>SN</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Escobar-Gomez</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Izak</LastName>
<ForeName>A</ForeName>
<Initials>A</Initials>
</Author>
</AuthorList>
<Language>ger</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Einfluss chirurgischer Faktoren auf die Kapsulotomierate dreistückiger Silikon-Intraokularlinsen - Analyse 457 pseudophaker Autopsieaugen12.</VernacularTitle>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Klin Monbl Augenheilkd</MedlineTA>
<NlmUniqueID>0014133</NlmUniqueID>
<ISSNLinking>0023-2165</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011126">Polypropylenes</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>9011-14-7</RegistryNumber>
<NameOfSubstance UI="D019904">Polymethyl Methacrylate</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002386">Cataract</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D053685">Laser Therapy</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007903">Lens Capsule, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019904">Polymethyl Methacrylate</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011126">Polypropylenes</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011183">Postoperative Complications</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019591">Pseudophakia</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012307">Risk Factors</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2001</Year>
<Month>9</Month>
<Day>27</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2002</Year>
<Month>1</Month>
<Day>5</Day>
<Hour>10</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2001</Year>
<Month>9</Month>
<Day>27</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">11573152</ArticleId>
<ArticleId IdType="doi">10.1055/s-2001-17133</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001D26 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001D26 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:11573152
   |texte=   [Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:11573152" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024