Plate-haptic silicone intraocular lens implantation: long-term results.
Identifieur interne : 001C84 ( PubMed/Corpus ); précédent : 001C83; suivant : 001C85Plate-haptic silicone intraocular lens implantation: long-term results.
Auteurs : Noémi Maár ; Irene Dejaco-Ruhswurm ; Martin Zehetmayer ; Christian SkorpikSource :
- Journal of cataract and refractive surgery [ 0886-3350 ] ; 2002.
English descriptors
- KwdEn :
- MESH :
- chemical : Biocompatible Materials, Silicone Elastomers.
- methods : Lens Implantation, Intraocular.
- Aged, Capsulorhexis, Female, Follow-Up Studies, Humans, Intraocular Pressure, Lenses, Intraocular, Male, Phacoemulsification, Postoperative Complications, Refraction, Ocular, Treatment Outcome, Visual Acuity.
Abstract
To present the 10- to 12-year functional and morphological results of in-the-bag implantation of a foldable, plate-haptic, silicone posterior chamber intraocular lens (IOL).
PubMed: 12036642
Links to Exploration step
pubmed:12036642Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Plate-haptic silicone intraocular lens implantation: long-term results.</title>
<author><name sortKey="Maar, Noemi" sort="Maar, Noemi" uniqKey="Maar N" first="Noémi" last="Maár">Noémi Maár</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, University of Vienna, Vienna, Austria. noemi.maar@univie.ac.at</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Dejaco Ruhswurm, Irene" sort="Dejaco Ruhswurm, Irene" uniqKey="Dejaco Ruhswurm I" first="Irene" last="Dejaco-Ruhswurm">Irene Dejaco-Ruhswurm</name>
</author>
<author><name sortKey="Zehetmayer, Martin" sort="Zehetmayer, Martin" uniqKey="Zehetmayer M" first="Martin" last="Zehetmayer">Martin Zehetmayer</name>
</author>
<author><name sortKey="Skorpik, Christian" sort="Skorpik, Christian" uniqKey="Skorpik C" first="Christian" last="Skorpik">Christian Skorpik</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2002">2002</date>
<idno type="RBID">pubmed:12036642</idno>
<idno type="pmid">12036642</idno>
<idno type="wicri:Area/PubMed/Corpus">001C84</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Plate-haptic silicone intraocular lens implantation: long-term results.</title>
<author><name sortKey="Maar, Noemi" sort="Maar, Noemi" uniqKey="Maar N" first="Noémi" last="Maár">Noémi Maár</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, University of Vienna, Vienna, Austria. noemi.maar@univie.ac.at</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Dejaco Ruhswurm, Irene" sort="Dejaco Ruhswurm, Irene" uniqKey="Dejaco Ruhswurm I" first="Irene" last="Dejaco-Ruhswurm">Irene Dejaco-Ruhswurm</name>
</author>
<author><name sortKey="Zehetmayer, Martin" sort="Zehetmayer, Martin" uniqKey="Zehetmayer M" first="Martin" last="Zehetmayer">Martin Zehetmayer</name>
</author>
<author><name sortKey="Skorpik, Christian" sort="Skorpik, Christian" uniqKey="Skorpik C" first="Christian" last="Skorpik">Christian Skorpik</name>
</author>
</analytic>
<series><title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint><date when="2002" type="published">2002</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Aged</term>
<term>Biocompatible Materials</term>
<term>Capsulorhexis</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Intraocular Pressure</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Refraction, Ocular</term>
<term>Silicone Elastomers</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Biocompatible Materials</term>
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Aged</term>
<term>Capsulorhexis</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Intraocular Pressure</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Refraction, Ocular</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To present the 10- to 12-year functional and morphological results of in-the-bag implantation of a foldable, plate-haptic, silicone posterior chamber intraocular lens (IOL).</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">12036642</PMID>
<DateCreated><Year>2002</Year>
<Month>05</Month>
<Day>30</Day>
</DateCreated>
<DateCompleted><Year>2002</Year>
<Month>07</Month>
<Day>29</Day>
</DateCompleted>
<DateRevised><Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print"><Volume>28</Volume>
<Issue>6</Issue>
<PubDate><Year>2002</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Plate-haptic silicone intraocular lens implantation: long-term results.</ArticleTitle>
<Pagination><MedlinePgn>992-7</MedlinePgn>
</Pagination>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To present the 10- to 12-year functional and morphological results of in-the-bag implantation of a foldable, plate-haptic, silicone posterior chamber intraocular lens (IOL).</AbstractText>
<AbstractText Label="SETTING" NlmCategory="METHODS">Department of Ophthalmology, University of Vienna Medical School, Vienna, Austria.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Between September 1987 and December 1989, 160 silicone posterior chamber IOLs (Staar AA-4203C) were implanted in the capsular bag through a 3.5 mm corneoscleral incision after a continuous curvilinear capsulorhexis was created. In spring 1999, 36 patients (38 eyes) could be included in a follow-up examination.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The median follow-up was 10.5 years +/- 2 (SD). The mean visual acuity was 0.82 +/- 0.34. The mean refraction (spherical equivalent) was +0.57 diopter (D), an insignificant change from the mean at the first postoperative follow-up at 1 month (+0.40 D). Slitlamp examination showed mildly dispersed pigment on the IOL surface in 81.58% of cases. All IOLs had a Tyndall effect (clouding). In 84.21%, the effect was minimal, in 10.53% it was moderate, and in 5.26% it was more intense. Ninety-two percent of the IOLs were centered within 0.5 mm. Of the 22 cases of decentration (57.89%), 86.36% were toward the 12 o'clock position in the bag. The neodymium:YAG capsulotomy rate was 10.52%. There were no cases of IOL-related inflammation or a clinically significant cystoid macular edema.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">The 10- to 12-year results suggest favorable clinical results of implantation of Staar AA-4203C plate-haptic, silicone posterior chamber IOLs.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Maár</LastName>
<ForeName>Noémi</ForeName>
<Initials>N</Initials>
<AffiliationInfo><Affiliation>Department of Ophthalmology, University of Vienna, Vienna, Austria. noemi.maar@univie.ac.at</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Dejaco-Ruhswurm</LastName>
<ForeName>Irene</ForeName>
<Initials>I</Initials>
</Author>
<Author ValidYN="Y"><LastName>Zehetmayer</LastName>
<ForeName>Martin</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y"><LastName>Skorpik</LastName>
<ForeName>Christian</ForeName>
<Initials>C</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D001672">Biocompatible Materials</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012826">Silicone Elastomers</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D001672">Biocompatible Materials</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D019923">Capsulorhexis</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005500">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007429">Intraocular Pressure</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011183">Postoperative Complications</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012029">Refraction, Ocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D012826">Silicone Elastomers</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D016896">Treatment Outcome</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>2002</Year>
<Month>5</Month>
<Day>31</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2002</Year>
<Month>7</Month>
<Day>30</Day>
<Hour>10</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2002</Year>
<Month>5</Month>
<Day>31</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">12036642</ArticleId>
<ArticleId IdType="pii">S0886335001012780</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001C84 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001C84 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:12036642 |texte= Plate-haptic silicone intraocular lens implantation: long-term results. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:12036642" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |