Silicone plate-haptic posterior chamber intraocular lens implanted in the anterior chamber: report of a bilateral case and potential complications.

Identifieur interne : 001C40 ( PubMed/Corpus ); précédent : 001C39; suivant : 001C41

Silicone plate-haptic posterior chamber intraocular lens implanted in the anterior chamber: report of a bilateral case and potential complications.

Auteurs : Andrea M. Izak ; Liliana Werner ; David J. Apple ; Suresh K. Pandey ; Rupal H. Trivedi

Source :

RBID : pubmed:12449223

English descriptors

Abstract

To evaluate possible complications associated with implantation of a posterior chamber (PC) intraocular lens (IOL) in the anterior chamber.

PubMed: 12449223

Links to Exploration step

pubmed:12449223

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Silicone plate-haptic posterior chamber intraocular lens implanted in the anterior chamber: report of a bilateral case and potential complications.</title>
<author>
<name sortKey="Izak, Andrea M" sort="Izak, Andrea M" uniqKey="Izak A" first="Andrea M" last="Izak">Andrea M. Izak</name>
<affiliation>
<nlm:affiliation>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Werner, Liliana" sort="Werner, Liliana" uniqKey="Werner L" first="Liliana" last="Werner">Liliana Werner</name>
</author>
<author>
<name sortKey="Apple, David J" sort="Apple, David J" uniqKey="Apple D" first="David J" last="Apple">David J. Apple</name>
</author>
<author>
<name sortKey="Pandey, Suresh K" sort="Pandey, Suresh K" uniqKey="Pandey S" first="Suresh K" last="Pandey">Suresh K. Pandey</name>
</author>
<author>
<name sortKey="Trivedi, Rupal H" sort="Trivedi, Rupal H" uniqKey="Trivedi R" first="Rupal H" last="Trivedi">Rupal H. Trivedi</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>2002 Nov-Dec</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:12449223</idno>
<idno type="pmid">12449223</idno>
<idno type="wicri:Area/PubMed/Corpus">001C40</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Silicone plate-haptic posterior chamber intraocular lens implanted in the anterior chamber: report of a bilateral case and potential complications.</title>
<author>
<name sortKey="Izak, Andrea M" sort="Izak, Andrea M" uniqKey="Izak A" first="Andrea M" last="Izak">Andrea M. Izak</name>
<affiliation>
<nlm:affiliation>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Werner, Liliana" sort="Werner, Liliana" uniqKey="Werner L" first="Liliana" last="Werner">Liliana Werner</name>
</author>
<author>
<name sortKey="Apple, David J" sort="Apple, David J" uniqKey="Apple D" first="David J" last="Apple">David J. Apple</name>
</author>
<author>
<name sortKey="Pandey, Suresh K" sort="Pandey, Suresh K" uniqKey="Pandey S" first="Suresh K" last="Pandey">Suresh K. Pandey</name>
</author>
<author>
<name sortKey="Trivedi, Rupal H" sort="Trivedi, Rupal H" uniqKey="Trivedi R" first="Rupal H" last="Trivedi">Rupal H. Trivedi</name>
</author>
</analytic>
<series>
<title level="j">Ophthalmic surgery and lasers</title>
<idno type="ISSN">1082-3069</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Anterior Chamber (surgery)</term>
<term>Cadaver</term>
<term>Device Removal</term>
<term>Female</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Postoperative Complications</term>
<term>Prosthesis Design</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Anterior Chamber</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Cadaver</term>
<term>Device Removal</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Postoperative Complications</term>
<term>Prosthesis Design</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To evaluate possible complications associated with implantation of a posterior chamber (PC) intraocular lens (IOL) in the anterior chamber.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">12449223</PMID>
<DateCreated>
<Year>2002</Year>
<Month>11</Month>
<Day>25</Day>
</DateCreated>
<DateCompleted>
<Year>2003</Year>
<Month>01</Month>
<Day>03</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1082-3069</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>33</Volume>
<Issue>6</Issue>
<PubDate>
<MedlineDate>2002 Nov-Dec</MedlineDate>
</PubDate>
</JournalIssue>
<Title>Ophthalmic surgery and lasers</Title>
<ISOAbbreviation>Ophthalmic Surg Lasers</ISOAbbreviation>
</Journal>
<ArticleTitle>Silicone plate-haptic posterior chamber intraocular lens implanted in the anterior chamber: report of a bilateral case and potential complications.</ArticleTitle>
<Pagination>
<MedlinePgn>480-7</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND AND OBJECTIVE" NlmCategory="OBJECTIVE">To evaluate possible complications associated with implantation of a posterior chamber (PC) intraocular lens (IOL) in the anterior chamber.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">We analyzed a plate-haptic silicone IOL that had been explanted from the anterior chamber of an 83-year-old female. Additionally, the lens was experimentally reimplanted into the anterior chambers of 3 human cadaver eyes. After fixation of the eyes (Karnovsky's solution), the anterior-posterior length, the white-to-white diameter, the angle-to-angle diameter, and the sulcus-to-sulcus diameter were measured. Two different techniques to cut the eyes were used: sagittal section and corneal buttonhole technique. The plate-haptic silicone lens was then implanted in the anterior chamber and sulcus ciliaris of the eyes. A Kelman multiflex IOL was used as a control for anterior chamber implantation.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">This experiment demonstrated that the plate-haptic silicone IOL lens is too small and thick for implantation in the anterior chamber and in the sulcus. The lens could easily rotate in the anterior chamber and also dislocate inferiorly, obstructing the visual axis by its edge. The thickness of the lens theoretically could also cause endothelial cell damage and mechanical iris irritation resulting in chronic uveal inflammation.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">This case and experiment should help surgeons realize the risk and potential for IOL-missizing complications that may be caused if a lens design for the capsular bag is implanted in the anterior chamber, especially if a plate-haptic PC-IOL design is used.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Izak</LastName>
<ForeName>Andrea M</ForeName>
<Initials>AM</Initials>
<AffiliationInfo>
<Affiliation>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Werner</LastName>
<ForeName>Liliana</ForeName>
<Initials>L</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Apple</LastName>
<ForeName>David J</ForeName>
<Initials>DJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Pandey</LastName>
<ForeName>Suresh K</ForeName>
<Initials>SK</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Trivedi</LastName>
<ForeName>Rupal H</ForeName>
<Initials>RH</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Ophthalmic Surg Lasers</MedlineTA>
<NlmUniqueID>9517132</NlmUniqueID>
<ISSNLinking>1082-3069</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012826">Silicone Elastomers</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000867">Anterior Chamber</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002102">Cadaver</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D020878">Device Removal</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011183">Postoperative Complications</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011475">Prosthesis Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012086">Reoperation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D012826">Silicone Elastomers</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2002</Year>
<Month>11</Month>
<Day>27</Day>
<Hour>4</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2003</Year>
<Month>1</Month>
<Day>7</Day>
<Hour>4</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2002</Year>
<Month>11</Month>
<Day>27</Day>
<Hour>4</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">12449223</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001C40 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001C40 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:12449223
   |texte=   Silicone plate-haptic posterior chamber intraocular lens implanted in the anterior chamber: report of a bilateral case and potential complications.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:12449223" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024