Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Effect of haptic design on change in axial lens position after cataract surgery.

Identifieur interne : 001B57 ( PubMed/Corpus ); précédent : 001B56; suivant : 001B58

Effect of haptic design on change in axial lens position after cataract surgery.

Auteurs : Matthias G. Wirtitsch ; Oliver Findl ; Rupert Menapace ; Katharina Kriechbaum ; Christina Koeppl ; Wolf Buehl ; Wolfgang Drexler

Source :

RBID : pubmed:14967267

English descriptors

Abstract

To compare the postoperative changes in anterior chamber depth (ACD) between single-piece and multipiece AcrySof intraocular lenses (IOLs) (Alcon Laboratories, Inc.) and their effect on the postoperative refractive shift.

DOI: 10.1016/S0886-3350(03)00459-0
PubMed: 14967267

Links to Exploration step

pubmed:14967267

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effect of haptic design on change in axial lens position after cataract surgery.</title>
<author>
<name sortKey="Wirtitsch, Matthias G" sort="Wirtitsch, Matthias G" uniqKey="Wirtitsch M" first="Matthias G" last="Wirtitsch">Matthias G. Wirtitsch</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, University of Vienna, Vienna, Austria.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Findl, Oliver" sort="Findl, Oliver" uniqKey="Findl O" first="Oliver" last="Findl">Oliver Findl</name>
</author>
<author>
<name sortKey="Menapace, Rupert" sort="Menapace, Rupert" uniqKey="Menapace R" first="Rupert" last="Menapace">Rupert Menapace</name>
</author>
<author>
<name sortKey="Kriechbaum, Katharina" sort="Kriechbaum, Katharina" uniqKey="Kriechbaum K" first="Katharina" last="Kriechbaum">Katharina Kriechbaum</name>
</author>
<author>
<name sortKey="Koeppl, Christina" sort="Koeppl, Christina" uniqKey="Koeppl C" first="Christina" last="Koeppl">Christina Koeppl</name>
</author>
<author>
<name sortKey="Buehl, Wolf" sort="Buehl, Wolf" uniqKey="Buehl W" first="Wolf" last="Buehl">Wolf Buehl</name>
</author>
<author>
<name sortKey="Drexler, Wolfgang" sort="Drexler, Wolfgang" uniqKey="Drexler W" first="Wolfgang" last="Drexler">Wolfgang Drexler</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2004">2004</date>
<idno type="RBID">pubmed:14967267</idno>
<idno type="pmid">14967267</idno>
<idno type="doi">10.1016/S0886-3350(03)00459-0</idno>
<idno type="wicri:Area/PubMed/Corpus">001B57</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Effect of haptic design on change in axial lens position after cataract surgery.</title>
<author>
<name sortKey="Wirtitsch, Matthias G" sort="Wirtitsch, Matthias G" uniqKey="Wirtitsch M" first="Matthias G" last="Wirtitsch">Matthias G. Wirtitsch</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, University of Vienna, Vienna, Austria.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Findl, Oliver" sort="Findl, Oliver" uniqKey="Findl O" first="Oliver" last="Findl">Oliver Findl</name>
</author>
<author>
<name sortKey="Menapace, Rupert" sort="Menapace, Rupert" uniqKey="Menapace R" first="Rupert" last="Menapace">Rupert Menapace</name>
</author>
<author>
<name sortKey="Kriechbaum, Katharina" sort="Kriechbaum, Katharina" uniqKey="Kriechbaum K" first="Katharina" last="Kriechbaum">Katharina Kriechbaum</name>
</author>
<author>
<name sortKey="Koeppl, Christina" sort="Koeppl, Christina" uniqKey="Koeppl C" first="Christina" last="Koeppl">Christina Koeppl</name>
</author>
<author>
<name sortKey="Buehl, Wolf" sort="Buehl, Wolf" uniqKey="Buehl W" first="Wolf" last="Buehl">Wolf Buehl</name>
</author>
<author>
<name sortKey="Drexler, Wolfgang" sort="Drexler, Wolfgang" uniqKey="Drexler W" first="Wolfgang" last="Drexler">Wolfgang Drexler</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2004" type="published">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Anterior Chamber (pathology)</term>
<term>Capsulorhexis</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
<term>Refraction, Ocular</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Anterior Chamber</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Capsulorhexis</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
<term>Refraction, Ocular</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To compare the postoperative changes in anterior chamber depth (ACD) between single-piece and multipiece AcrySof intraocular lenses (IOLs) (Alcon Laboratories, Inc.) and their effect on the postoperative refractive shift.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">14967267</PMID>
<DateCreated>
<Year>2004</Year>
<Month>02</Month>
<Day>17</Day>
</DateCreated>
<DateCompleted>
<Year>2004</Year>
<Month>03</Month>
<Day>08</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>30</Volume>
<Issue>1</Issue>
<PubDate>
<Year>2004</Year>
<Month>Jan</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Effect of haptic design on change in axial lens position after cataract surgery.</ArticleTitle>
<Pagination>
<MedlinePgn>45-51</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To compare the postoperative changes in anterior chamber depth (ACD) between single-piece and multipiece AcrySof intraocular lenses (IOLs) (Alcon Laboratories, Inc.) and their effect on the postoperative refractive shift.</AbstractText>
<AbstractText Label="SETTING" NlmCategory="METHODS">Department of Ophthalmology, University of Vienna, Vienna, Austria.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">This prospective randomized bilateral study with intraindividual comparison comprised 104 eyes of 52 consecutive patients with age-related cataract. All patients had standardized cataract surgery with a temporal self-sealing incision, phacoemulsification, and IOL implantation in the capsular bag. The first 30 patients received a single-piece, 5.5 mm optic IOL (AcrySof SA30) in 1 eye and a multipiece IOL (AcrySof MA30) in the other eye. Another 22 patients received the corresponding 6.0 mm optic models (AcrySof SA60 and AcrySof MA60, respectively). Anterior chamber depth measurements and evaluation of the change in ACD during the first 6 postoperative months were performed using partial coherence laser interferometry. The amount of change in capsulorhexis size during the first 6 postoperative months was assessed using standardized retroillumination photographs.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Single-piece IOLs shifted significantly less postoperatively than multipiece IOLs. The multipiece IOLs shifted forward, especially from 1 day to 1 month. The change in the capsulorhexis area was similar between IOL types.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Single-piece AcrySof IOLs shifted minimally after the first postoperative day; therefore, the prescription for spectacles in eyes with this IOL can be obtained soon after surgery.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Wirtitsch</LastName>
<ForeName>Matthias G</ForeName>
<Initials>MG</Initials>
<AffiliationInfo>
<Affiliation>Department of Ophthalmology, University of Vienna, Vienna, Austria.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Findl</LastName>
<ForeName>Oliver</ForeName>
<Initials>O</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Menapace</LastName>
<ForeName>Rupert</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Kriechbaum</LastName>
<ForeName>Katharina</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Koeppl</LastName>
<ForeName>Christina</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Buehl</LastName>
<ForeName>Wolf</ForeName>
<Initials>W</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Drexler</LastName>
<ForeName>Wolfgang</ForeName>
<Initials>W</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016430">Clinical Trial</PublicationType>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D016449">Randomized Controlled Trial</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000867">Anterior Chamber</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019923">Capsulorhexis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011183">Postoperative Complications</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011446">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012029">Refraction, Ocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2004</Year>
<Month>2</Month>
<Day>18</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2004</Year>
<Month>3</Month>
<Day>9</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2003</Year>
<Month>May</Month>
<Day>13</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2004</Year>
<Month>2</Month>
<Day>18</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">14967267</ArticleId>
<ArticleId IdType="doi">10.1016/S0886-3350(03)00459-0</ArticleId>
<ArticleId IdType="pii">S0886335003004590</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001B57 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001B57 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:14967267
   |texte=   Effect of haptic design on change in axial lens position after cataract surgery.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:14967267" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024