Effect of anterior capsule polishing on fibrotic capsule opacification: three-year results.

Identifieur interne : 001A40 ( PubMed/Corpus ); précédent : 001A39; suivant : 001A41

Effect of anterior capsule polishing on fibrotic capsule opacification: three-year results.

Auteurs : Stefan Sacu ; Rupert Menapace ; Matthias Wirtitsch ; Wolf Buehl ; Georg Rainer ; Oliver Findl

Source :

RBID : pubmed:15519082

English descriptors

Abstract

To evaluate the long-term effect of anterior capsule polishing on anterior capsule opacification (ACO) and peripheral fibrotic posterior capsule opacification (PCO).

DOI: 10.1016/j.jcrs.2004.02.092
PubMed: 15519082

Links to Exploration step

pubmed:15519082

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effect of anterior capsule polishing on fibrotic capsule opacification: three-year results.</title>
<author>
<name sortKey="Sacu, Stefan" sort="Sacu, Stefan" uniqKey="Sacu S" first="Stefan" last="Sacu">Stefan Sacu</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, Medical University of Vienna, Medical School, Vienna, Austria.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Menapace, Rupert" sort="Menapace, Rupert" uniqKey="Menapace R" first="Rupert" last="Menapace">Rupert Menapace</name>
</author>
<author>
<name sortKey="Wirtitsch, Matthias" sort="Wirtitsch, Matthias" uniqKey="Wirtitsch M" first="Matthias" last="Wirtitsch">Matthias Wirtitsch</name>
</author>
<author>
<name sortKey="Buehl, Wolf" sort="Buehl, Wolf" uniqKey="Buehl W" first="Wolf" last="Buehl">Wolf Buehl</name>
</author>
<author>
<name sortKey="Rainer, Georg" sort="Rainer, Georg" uniqKey="Rainer G" first="Georg" last="Rainer">Georg Rainer</name>
</author>
<author>
<name sortKey="Findl, Oliver" sort="Findl, Oliver" uniqKey="Findl O" first="Oliver" last="Findl">Oliver Findl</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2004">2004</date>
<idno type="doi">10.1016/j.jcrs.2004.02.092</idno>
<idno type="RBID">pubmed:15519082</idno>
<idno type="pmid">15519082</idno>
<idno type="wicri:Area/PubMed/Corpus">001A40</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Effect of anterior capsule polishing on fibrotic capsule opacification: three-year results.</title>
<author>
<name sortKey="Sacu, Stefan" sort="Sacu, Stefan" uniqKey="Sacu S" first="Stefan" last="Sacu">Stefan Sacu</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, Medical University of Vienna, Medical School, Vienna, Austria.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Menapace, Rupert" sort="Menapace, Rupert" uniqKey="Menapace R" first="Rupert" last="Menapace">Rupert Menapace</name>
</author>
<author>
<name sortKey="Wirtitsch, Matthias" sort="Wirtitsch, Matthias" uniqKey="Wirtitsch M" first="Matthias" last="Wirtitsch">Matthias Wirtitsch</name>
</author>
<author>
<name sortKey="Buehl, Wolf" sort="Buehl, Wolf" uniqKey="Buehl W" first="Wolf" last="Buehl">Wolf Buehl</name>
</author>
<author>
<name sortKey="Rainer, Georg" sort="Rainer, Georg" uniqKey="Rainer G" first="Georg" last="Rainer">Georg Rainer</name>
</author>
<author>
<name sortKey="Findl, Oliver" sort="Findl, Oliver" uniqKey="Findl O" first="Oliver" last="Findl">Oliver Findl</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2004" type="published">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Capsulorhexis</term>
<term>Cataract (etiology)</term>
<term>Double-Blind Method</term>
<term>Epithelial Cells (pathology)</term>
<term>Fibrosis</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Incidence</term>
<term>Lens Capsule, Crystalline (pathology)</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Phacoemulsification</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
<term>Silicone Elastomers</term>
<term>Suction (methods)</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Cataract</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Suction</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Epithelial Cells</term>
<term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Capsulorhexis</term>
<term>Double-Blind Method</term>
<term>Fibrosis</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Incidence</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Phacoemulsification</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To evaluate the long-term effect of anterior capsule polishing on anterior capsule opacification (ACO) and peripheral fibrotic posterior capsule opacification (PCO).</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">15519082</PMID>
<DateCreated>
<Year>2004</Year>
<Month>11</Month>
<Day>02</Day>
</DateCreated>
<DateCompleted>
<Year>2005</Year>
<Month>01</Month>
<Day>24</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>30</Volume>
<Issue>11</Issue>
<PubDate>
<Year>2004</Year>
<Month>Nov</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Effect of anterior capsule polishing on fibrotic capsule opacification: three-year results.</ArticleTitle>
<Pagination>
<MedlinePgn>2322-7</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To evaluate the long-term effect of anterior capsule polishing on anterior capsule opacification (ACO) and peripheral fibrotic posterior capsule opacification (PCO).</AbstractText>
<AbstractText Label="SETTING" NlmCategory="METHODS">Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">This randomized double-blind study comprised 104 eyes of 52 patients with bilateral age-related cataract. All patients received round-edged intraocular lenses (IOLs); 26 received an SI-40 IOL (Advanced Medical Optics Inc.) in both eyes, and 26 received a Silens6 IOL (Domilens) in both eyes. Both IOLs consist of different silicone material and have different haptic angulation. The SI-40 IOL has 13.0 mm open-loop poly(methyl methacrylate) (PMMA) haptics angulated by 10 degrees. The Silens6 IOL has 12.5 mm open-loop PMMA haptics with no angulation. In 1 eye, the anterior capsule was extensively polished. The anterior capsule was left unpolished in the contralateral eye, which acted as a control. Digital slitlamp photographs of the ACO and fibrotic PCO were taken with a standardized technique for 3 years postoperatively. The intensity of ACO was measured objectively (score 0% to 100%) using Adobe Photoshop software. Fibrotic PCO was graded subjectively (score 0 to 4).</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The mean ACO was 17% in the polished eyes and 26% in the control eyes (P = .0001). The mean fibrotic PCO score was 0.5 and 1.0, respectively (P = .0007). The mean ACO was 15% in the polished SI-40 eyes and 26% in the control SI-40 eyes (P = .01). It was 19% in the polished Silens6 eyes and 26% in the control Silens6 eyes (P = .003). The mean fibrotic PCO score was 0.4 in the polished SI-40 eyes and 1.1 in the control SI-40 eyes (P = .0006). It was 0.6 in the polished Silens6 eyes and 0.9 in the control Silens6 eyes (P = .08).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Three years after surgery, eyes in which the anterior capsule was extensively polished had less ACO and fibrotic PCO with both round-edged silicone IOLs. In eyes with Silens6 IOLs, however, the reduction in fibrotic PCO was not significant.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Sacu</LastName>
<ForeName>Stefan</ForeName>
<Initials>S</Initials>
<AffiliationInfo>
<Affiliation>Department of Ophthalmology, Medical University of Vienna, Medical School, Vienna, Austria.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Menapace</LastName>
<ForeName>Rupert</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Wirtitsch</LastName>
<ForeName>Matthias</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Buehl</LastName>
<ForeName>Wolf</ForeName>
<Initials>W</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Rainer</LastName>
<ForeName>Georg</ForeName>
<Initials>G</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Findl</LastName>
<ForeName>Oliver</ForeName>
<Initials>O</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016430">Clinical Trial</PublicationType>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D016449">Randomized Controlled Trial</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012826">Silicone Elastomers</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019923">Capsulorhexis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002386">Cataract</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D004311">Double-Blind Method</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D004847">Epithelial Cells</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005355">Fibrosis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005500">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D015994">Incidence</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007903">Lens Capsule, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011446">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012826">Silicone Elastomers</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013396">Suction</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="accepted">
<Year>2004</Year>
<Month>Feb</Month>
<Day>24</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2004</Year>
<Month>11</Month>
<Day>3</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2005</Year>
<Month>1</Month>
<Day>26</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2004</Year>
<Month>11</Month>
<Day>3</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0886335004004195</ArticleId>
<ArticleId IdType="doi">10.1016/j.jcrs.2004.02.092</ArticleId>
<ArticleId IdType="pubmed">15519082</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001A40 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001A40 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:15519082
   |texte=   Effect of anterior capsule polishing on fibrotic capsule opacification: three-year results.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:15519082" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024