Haptic rendering & perception studies for laparoscopic surgery simulation.

Identifieur interne : 001568 ( PubMed/Corpus ); précédent : 001567; suivant : 001569

Haptic rendering & perception studies for laparoscopic surgery simulation.

Auteurs : Ryan Mccoll ; A P Ian Brown ; Cory Seligman ; Fabian Lim ; Amer Alsaraira

Source :

RBID : pubmed:17946424

English descriptors

Abstract

This project concerns the application of haptic feedback to a virtual reality laparoscopic surgery simulator. Haptic attributes such as mass, friction, stiction, elasticity, roughness and viscosity are individually modeled, validated and applied to the existing visual simulation created by researchers at Monash University. Validation studies has shown that refinements to our mechanical interface improves the accuracy of localisation by 25%. Using our mechanical interface, the JND (Just Noticeable Difference) for instantaneous change of magnitude of haptic attributes is approximately 12%. This suggests the mechanical interface is suitable to use for surgery based studies. There are times in surgery when the view from the camera cannot be depended upon. When visual feedback is impeded, haptic feedback must be relied upon more by the surgeon. A realistic simulator should include some sort of visual impedance. Results from a simple tissue holding task suggested the inclusion of haptic feedback in a simulator aids the user when visual feedback is impeded. Haptic force feedback modeling, systems implementation, threshold and level perception, and validation studies form the principal areas of new work associated with this project.

DOI: 10.1109/IEMBS.2006.260053
PubMed: 17946424

Links to Exploration step

pubmed:17946424

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Haptic rendering & perception studies for laparoscopic surgery simulation.</title>
<author>
<name sortKey="Mccoll, Ryan" sort="Mccoll, Ryan" uniqKey="Mccoll R" first="Ryan" last="Mccoll">Ryan Mccoll</name>
<affiliation>
<nlm:affiliation>Department of Electrical & Computer Systems Engineering, Monash University, Clayton, Victoria, Australia. ryan.mccoll@eng.monash.edu.au</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Brown, A P Ian" sort="Brown, A P Ian" uniqKey="Brown A" first="A P Ian" last="Brown">A P Ian Brown</name>
</author>
<author>
<name sortKey="Seligman, Cory" sort="Seligman, Cory" uniqKey="Seligman C" first="Cory" last="Seligman">Cory Seligman</name>
</author>
<author>
<name sortKey="Lim, Fabian" sort="Lim, Fabian" uniqKey="Lim F" first="Fabian" last="Lim">Fabian Lim</name>
</author>
<author>
<name sortKey="Alsaraira, Amer" sort="Alsaraira, Amer" uniqKey="Alsaraira A" first="Amer" last="Alsaraira">Amer Alsaraira</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2006">2006</date>
<idno type="doi">10.1109/IEMBS.2006.260053</idno>
<idno type="RBID">pubmed:17946424</idno>
<idno type="pmid">17946424</idno>
<idno type="wicri:Area/PubMed/Corpus">001568</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Haptic rendering & perception studies for laparoscopic surgery simulation.</title>
<author>
<name sortKey="Mccoll, Ryan" sort="Mccoll, Ryan" uniqKey="Mccoll R" first="Ryan" last="Mccoll">Ryan Mccoll</name>
<affiliation>
<nlm:affiliation>Department of Electrical & Computer Systems Engineering, Monash University, Clayton, Victoria, Australia. ryan.mccoll@eng.monash.edu.au</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Brown, A P Ian" sort="Brown, A P Ian" uniqKey="Brown A" first="A P Ian" last="Brown">A P Ian Brown</name>
</author>
<author>
<name sortKey="Seligman, Cory" sort="Seligman, Cory" uniqKey="Seligman C" first="Cory" last="Seligman">Cory Seligman</name>
</author>
<author>
<name sortKey="Lim, Fabian" sort="Lim, Fabian" uniqKey="Lim F" first="Fabian" last="Lim">Fabian Lim</name>
</author>
<author>
<name sortKey="Alsaraira, Amer" sort="Alsaraira, Amer" uniqKey="Alsaraira A" first="Amer" last="Alsaraira">Amer Alsaraira</name>
</author>
</analytic>
<series>
<title level="j">Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference</title>
<idno type="ISSN">1557-170X</idno>
<imprint>
<date when="2006" type="published">2006</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Computer Simulation</term>
<term>Humans</term>
<term>Laparoscopy (methods)</term>
<term>Male</term>
<term>Models, Biological</term>
<term>Physical Stimulation (methods)</term>
<term>Stress, Mechanical</term>
<term>Surgery, Computer-Assisted (methods)</term>
<term>Touch (physiology)</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Laparoscopy</term>
<term>Physical Stimulation</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Touch</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Computer Simulation</term>
<term>Humans</term>
<term>Male</term>
<term>Models, Biological</term>
<term>Stress, Mechanical</term>
<term>User-Computer Interface</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This project concerns the application of haptic feedback to a virtual reality laparoscopic surgery simulator. Haptic attributes such as mass, friction, stiction, elasticity, roughness and viscosity are individually modeled, validated and applied to the existing visual simulation created by researchers at Monash University. Validation studies has shown that refinements to our mechanical interface improves the accuracy of localisation by 25%. Using our mechanical interface, the JND (Just Noticeable Difference) for instantaneous change of magnitude of haptic attributes is approximately 12%. This suggests the mechanical interface is suitable to use for surgery based studies. There are times in surgery when the view from the camera cannot be depended upon. When visual feedback is impeded, haptic feedback must be relied upon more by the surgeon. A realistic simulator should include some sort of visual impedance. Results from a simple tissue holding task suggested the inclusion of haptic feedback in a simulator aids the user when visual feedback is impeded. Haptic force feedback modeling, systems implementation, threshold and level perception, and validation studies form the principal areas of new work associated with this project.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">17946424</PMID>
<DateCreated>
<Year>2007</Year>
<Month>10</Month>
<Day>23</Day>
</DateCreated>
<DateCompleted>
<Year>2008</Year>
<Month>03</Month>
<Day>19</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>08</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1557-170X</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>1</Volume>
<PubDate>
<Year>2006</Year>
</PubDate>
</JournalIssue>
<Title>Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference</Title>
<ISOAbbreviation>Conf Proc IEEE Eng Med Biol Soc</ISOAbbreviation>
</Journal>
<ArticleTitle>Haptic rendering & perception studies for laparoscopic surgery simulation.</ArticleTitle>
<Pagination>
<MedlinePgn>833-6</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>This project concerns the application of haptic feedback to a virtual reality laparoscopic surgery simulator. Haptic attributes such as mass, friction, stiction, elasticity, roughness and viscosity are individually modeled, validated and applied to the existing visual simulation created by researchers at Monash University. Validation studies has shown that refinements to our mechanical interface improves the accuracy of localisation by 25%. Using our mechanical interface, the JND (Just Noticeable Difference) for instantaneous change of magnitude of haptic attributes is approximately 12%. This suggests the mechanical interface is suitable to use for surgery based studies. There are times in surgery when the view from the camera cannot be depended upon. When visual feedback is impeded, haptic feedback must be relied upon more by the surgeon. A realistic simulator should include some sort of visual impedance. Results from a simple tissue holding task suggested the inclusion of haptic feedback in a simulator aids the user when visual feedback is impeded. Haptic force feedback modeling, systems implementation, threshold and level perception, and validation studies form the principal areas of new work associated with this project.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>McColl</LastName>
<ForeName>Ryan</ForeName>
<Initials>R</Initials>
<AffiliationInfo>
<Affiliation>Department of Electrical & Computer Systems Engineering, Monash University, Clayton, Victoria, Australia. ryan.mccoll@eng.monash.edu.au</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Brown</LastName>
<ForeName>A P Ian</ForeName>
<Initials>AP</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Seligman</LastName>
<ForeName>Cory</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Lim</LastName>
<ForeName>Fabian</ForeName>
<Initials>F</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Alsaraira</LastName>
<ForeName>Amer</ForeName>
<Initials>A</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Conf Proc IEEE Eng Med Biol Soc</MedlineTA>
<NlmUniqueID>101243413</NlmUniqueID>
<ISSNLinking>1557-170X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003198">Computer Simulation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D010535">Laparoscopy</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D008954">Models, Biological</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D010812">Physical Stimulation</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013314">Stress, Mechanical</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D025321">Surgery, Computer-Assisted</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014110">Touch</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014584">User-Computer Interface</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2007</Year>
<Month>10</Month>
<Day>20</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2008</Year>
<Month>3</Month>
<Day>20</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2007</Year>
<Month>10</Month>
<Day>20</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1109/IEMBS.2006.260053</ArticleId>
<ArticleId IdType="pubmed">17946424</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001568 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001568 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:17946424
   |texte=   Haptic rendering & perception studies for laparoscopic surgery simulation.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:17946424" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024