Suture fixation technique for a single-piece foldable closed-loop intraocular lens.
Identifieur interne : 001355 ( PubMed/Corpus ); précédent : 001354; suivant : 001356Suture fixation technique for a single-piece foldable closed-loop intraocular lens.
Auteurs : Chang Hyun Park ; Sung Jin LeeSource :
- Korean journal of ophthalmology : KJO [ 1011-8942 ] ; 2008.
English descriptors
- KwdEn :
- MESH :
- chemical : Acrylic Resins, Polypropylenes.
- methods : Lens Implantation, Intraocular.
- Adult, Aged, Aged, 80 and over, Female, Humans, Lenses, Intraocular, Male, Middle Aged, Prosthesis Design, Suture Techniques, Sutures, Treatment Outcome, Visual Acuity, Vitrectomy.
Abstract
We describe a suture fixation technique for a single-piece foldable acrylic closed-loop intraocular lens (IOL) (C-flex, Rayner).
DOI: 10.3341/kjo.2008.22.4.205
PubMed: 19096235
Links to Exploration step
pubmed:19096235Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Suture fixation technique for a single-piece foldable closed-loop intraocular lens.</title>
<author><name sortKey="Park, Chang Hyun" sort="Park, Chang Hyun" uniqKey="Park C" first="Chang Hyun" last="Park">Chang Hyun Park</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, Soonchunhyang University Hospital, Seoul, Korea.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Lee, Sung Jin" sort="Lee, Sung Jin" uniqKey="Lee S" first="Sung Jin" last="Lee">Sung Jin Lee</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2008">2008</date>
<idno type="doi">10.3341/kjo.2008.22.4.205</idno>
<idno type="RBID">pubmed:19096235</idno>
<idno type="pmid">19096235</idno>
<idno type="wicri:Area/PubMed/Corpus">001355</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Suture fixation technique for a single-piece foldable closed-loop intraocular lens.</title>
<author><name sortKey="Park, Chang Hyun" sort="Park, Chang Hyun" uniqKey="Park C" first="Chang Hyun" last="Park">Chang Hyun Park</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, Soonchunhyang University Hospital, Seoul, Korea.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Lee, Sung Jin" sort="Lee, Sung Jin" uniqKey="Lee S" first="Sung Jin" last="Lee">Sung Jin Lee</name>
</author>
</analytic>
<series><title level="j">Korean journal of ophthalmology : KJO</title>
<idno type="ISSN">1011-8942</idno>
<imprint><date when="2008" type="published">2008</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Acrylic Resins</term>
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Polypropylenes</term>
<term>Prosthesis Design</term>
<term>Suture Techniques</term>
<term>Sutures</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
<term>Vitrectomy</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Acrylic Resins</term>
<term>Polypropylenes</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Prosthesis Design</term>
<term>Suture Techniques</term>
<term>Sutures</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
<term>Vitrectomy</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">We describe a suture fixation technique for a single-piece foldable acrylic closed-loop intraocular lens (IOL) (C-flex, Rayner).</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">19096235</PMID>
<DateCreated><Year>2008</Year>
<Month>12</Month>
<Day>19</Day>
</DateCreated>
<DateCompleted><Year>2009</Year>
<Month>02</Month>
<Day>17</Day>
</DateCompleted>
<DateRevised><Year>2014</Year>
<Month>09</Month>
<Day>01</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">1011-8942</ISSN>
<JournalIssue CitedMedium="Print"><Volume>22</Volume>
<Issue>4</Issue>
<PubDate><Year>2008</Year>
<Month>Dec</Month>
</PubDate>
</JournalIssue>
<Title>Korean journal of ophthalmology : KJO</Title>
<ISOAbbreviation>Korean J Ophthalmol</ISOAbbreviation>
</Journal>
<ArticleTitle>Suture fixation technique for a single-piece foldable closed-loop intraocular lens.</ArticleTitle>
<Pagination><MedlinePgn>205-9</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.3341/kjo.2008.22.4.205</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">We describe a suture fixation technique for a single-piece foldable acrylic closed-loop intraocular lens (IOL) (C-flex, Rayner).</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">In our experimental model analyzing the stability of acrylic haptics, we confirmed that the IOL could be in counterpoise without tilt using only a two-point fixation. This new surgical technique was performed in seven patients.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The unique haptic design allows easy and secure suture fixation. The clinical outcomes were encouraging.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">It is conceivable that better stabilization can be achieved by the broad arc of distal haptic-tissue contact, in addition to suture fixation, using our surgical technique with the C-flex IOL.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Park</LastName>
<ForeName>Chang Hyun</ForeName>
<Initials>CH</Initials>
<AffiliationInfo><Affiliation>Department of Ophthalmology, Soonchunhyang University Hospital, Seoul, Korea.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Lee</LastName>
<ForeName>Sung Jin</ForeName>
<Initials>SJ</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>Korea (South)</Country>
<MedlineTA>Korean J Ophthalmol</MedlineTA>
<NlmUniqueID>8804513</NlmUniqueID>
<ISSNLinking>1011-8942</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011126">Polypropylenes</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<CommentsCorrectionsList><CommentsCorrections RefType="Cites"><RefSource>Ophthalmic Surg Lasers Imaging. 2004 Sep-Oct;35(5):379-82</RefSource>
<PMID Version="1">15497548</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>J Cataract Refract Surg. 2004 Apr;30(4):854-7</RefSource>
<PMID Version="1">15093650</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Cornea. 1991 May;10(3):244-8</RefSource>
<PMID Version="1">2055031</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Arch Ophthalmol. 1994 Nov;112(11):1485-7</RefSource>
<PMID Version="1">7980140</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>J Cataract Refract Surg. 1997 Jan-Feb;23(1):91-6</RefSource>
<PMID Version="1">9100114</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>J Cataract Refract Surg. 1998 Jul;24(7):889</RefSource>
<PMID Version="1">9682105</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>J Cataract Refract Surg. 1999 Mar;25(3):420-6</RefSource>
<PMID Version="1">10079450</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Can J Ophthalmol. 2007 Apr;42(2):256-61</RefSource>
<PMID Version="1">17392849</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>J Cataract Refract Surg. 2000 Feb;26(2):266-70</RefSource>
<PMID Version="1">10683796</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Curr Opin Ophthalmol. 2001 Jun;12(3):216-21</RefSource>
<PMID Version="1">11389350</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>J Cataract Refract Surg. 2001 Nov;27(11):1884-8</RefSource>
<PMID Version="1">11709266</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>J Cataract Refract Surg. 2002 Jan;28(1):182-5</RefSource>
<PMID Version="1">11777728</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Ophthalmic Surg Lasers. 2002 May-Jun;33(3):257-9</RefSource>
<PMID Version="1">12027112</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>J Cataract Refract Surg. 2003 Feb;29(2):294-300</RefSource>
<PMID Version="1">12648640</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>J Cataract Refract Surg. 2003 Dec;29(12):2390-6</RefSource>
<PMID Version="1">14709302</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites"><RefSource>Am J Ophthalmol. 1989 Sep 15;108(3):300-9</RefSource>
<PMID Version="1">2672820</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000180">Acrylic Resins</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011126">Polypropylenes</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D013536">Suture Techniques</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D013537">Sutures</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D016896">Treatment Outcome</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014821">Vitrectomy</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<OtherID Source="NLM">PMC2629918</OtherID>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2008</Year>
<Month>12</Month>
<Day>20</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2008</Year>
<Month>12</Month>
<Day>20</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2009</Year>
<Month>2</Month>
<Day>20</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pii">200812205</ArticleId>
<ArticleId IdType="doi">10.3341/kjo.2008.22.4.205</ArticleId>
<ArticleId IdType="pubmed">19096235</ArticleId>
<ArticleId IdType="pmc">PMC2629918</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001355 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001355 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:19096235 |texte= Suture fixation technique for a single-piece foldable closed-loop intraocular lens. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:19096235" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |