Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction.

Identifieur interne : 001173 ( PubMed/Corpus ); précédent : 001172; suivant : 001174

Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction.

Auteurs : I Aki Rodríguez-Agirretxe ; Arantxa Acera-Osa ; Marta Ubeda-Erviti

Source :

RBID : pubmed:19969207

English descriptors

Abstract

We present a technique for the surgical correction of aphakia that allows intrascleral fixation of a posterior chamber intraocular lens (IOL) without sutures. The technique is useful in situations in which one haptic has to be fixated and capsule support is adequate for fixation of the second haptic. The haptic is externalized with a 25-gauge needle; no surgical instrumentation other than that needed for conventional cataract surgery is used. The technique is particularly appropriate for 3-piece IOLs with flexible haptics.

DOI: 10.1016/j.jcrs.2009.06.044
PubMed: 19969207

Links to Exploration step

pubmed:19969207

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction.</title>
<author>
<name sortKey="Rodriguez Agirretxe, I Aki" sort="Rodriguez Agirretxe, I Aki" uniqKey="Rodriguez Agirretxe I" first="I Aki" last="Rodríguez-Agirretxe">I Aki Rodríguez-Agirretxe</name>
<affiliation>
<nlm:affiliation>Instituto Clínico Quirúrgico de Oftalmología, Virgen de Begoña 34, Bilbao (48006), Vizcaya, Spain. ira@icqo.org</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Acera Osa, Arantxa" sort="Acera Osa, Arantxa" uniqKey="Acera Osa A" first="Arantxa" last="Acera-Osa">Arantxa Acera-Osa</name>
</author>
<author>
<name sortKey="Ubeda Erviti, Marta" sort="Ubeda Erviti, Marta" uniqKey="Ubeda Erviti M" first="Marta" last="Ubeda-Erviti">Marta Ubeda-Erviti</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2009">2009</date>
<idno type="doi">10.1016/j.jcrs.2009.06.044</idno>
<idno type="RBID">pubmed:19969207</idno>
<idno type="pmid">19969207</idno>
<idno type="wicri:Area/PubMed/Corpus">001173</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction.</title>
<author>
<name sortKey="Rodriguez Agirretxe, I Aki" sort="Rodriguez Agirretxe, I Aki" uniqKey="Rodriguez Agirretxe I" first="I Aki" last="Rodríguez-Agirretxe">I Aki Rodríguez-Agirretxe</name>
<affiliation>
<nlm:affiliation>Instituto Clínico Quirúrgico de Oftalmología, Virgen de Begoña 34, Bilbao (48006), Vizcaya, Spain. ira@icqo.org</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Acera Osa, Arantxa" sort="Acera Osa, Arantxa" uniqKey="Acera Osa A" first="Arantxa" last="Acera-Osa">Arantxa Acera-Osa</name>
</author>
<author>
<name sortKey="Ubeda Erviti, Marta" sort="Ubeda Erviti, Marta" uniqKey="Ubeda Erviti M" first="Marta" last="Ubeda-Erviti">Marta Ubeda-Erviti</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="eISSN">1873-4502</idno>
<imprint>
<date when="2009" type="published">2009</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aphakia, Postcataract (surgery)</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Sclera (surgery)</term>
<term>Suture Techniques</term>
<term>Visual Acuity (physiology)</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Aphakia, Postcataract</term>
<term>Sclera</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Suture Techniques</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We present a technique for the surgical correction of aphakia that allows intrascleral fixation of a posterior chamber intraocular lens (IOL) without sutures. The technique is useful in situations in which one haptic has to be fixated and capsule support is adequate for fixation of the second haptic. The haptic is externalized with a 25-gauge needle; no surgical instrumentation other than that needed for conventional cataract surgery is used. The technique is particularly appropriate for 3-piece IOLs with flexible haptics.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">19969207</PMID>
<DateCreated>
<Year>2009</Year>
<Month>12</Month>
<Day>08</Day>
</DateCreated>
<DateCompleted>
<Year>2010</Year>
<Month>02</Month>
<Day>26</Day>
</DateCompleted>
<DateRevised>
<Year>2010</Year>
<Month>05</Month>
<Day>26</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1873-4502</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>35</Volume>
<Issue>12</Issue>
<PubDate>
<Year>2009</Year>
<Month>Dec</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction.</ArticleTitle>
<Pagination>
<MedlinePgn>2051-3</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.jcrs.2009.06.044</ELocationID>
<Abstract>
<AbstractText>We present a technique for the surgical correction of aphakia that allows intrascleral fixation of a posterior chamber intraocular lens (IOL) without sutures. The technique is useful in situations in which one haptic has to be fixated and capsule support is adequate for fixation of the second haptic. The haptic is externalized with a 25-gauge needle; no surgical instrumentation other than that needed for conventional cataract surgery is used. The technique is particularly appropriate for 3-piece IOLs with flexible haptics.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Rodríguez-Agirretxe</LastName>
<ForeName>Iñaki</ForeName>
<Initials>I</Initials>
<AffiliationInfo>
<Affiliation>Instituto Clínico Quirúrgico de Oftalmología, Virgen de Begoña 34, Bilbao (48006), Vizcaya, Spain. ira@icqo.org</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Acera-Osa</LastName>
<ForeName>Arantxa</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ubeda-Erviti</LastName>
<ForeName>Marta</ForeName>
<Initials>M</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<CommentsCorrectionsList>
<CommentsCorrections RefType="CommentIn">
<RefSource>J Cataract Refract Surg. 2010 Jun;36(6):1063; author reply 1063</RefSource>
<PMID Version="1">20494798</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001036">Aphakia, Postcataract</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012590">Sclera</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013536">Suture Techniques</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2009</Year>
<Month>1</Month>
<Day>25</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised">
<Year>2009</Year>
<Month>6</Month>
<Day>20</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2009</Year>
<Month>6</Month>
<Day>22</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2009</Year>
<Month>12</Month>
<Day>9</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2009</Year>
<Month>12</Month>
<Day>9</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2010</Year>
<Month>2</Month>
<Day>27</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0886-3350(09)00888-8</ArticleId>
<ArticleId IdType="doi">10.1016/j.jcrs.2009.06.044</ArticleId>
<ArticleId IdType="pubmed">19969207</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001173 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001173 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:19969207
   |texte=   Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:19969207" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024