Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.

Identifieur interne : 000E77 ( PubMed/Corpus ); précédent : 000E76; suivant : 000E78

Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.

Auteurs : O. Goksel ; K. Sapchuk ; S E Salcudean

Source :

RBID : pubmed:26963486

Abstract

This paper presents a haptic simulator for prostate brachytherapy. Both needle insertion and the manipulation of the transrectal ultrasound (TRUS) probe are controlled via haptic devices. Tissue interaction forces that are computed by a deformable tissue model based on the finite element method (FEM) are rendered to the user by these devices. The needle insertion simulation employs 3D models of needle flexibility and asymmetric tip bevel. The needle-tissue simulation allows a trainee to practice needle insertion and targeting. The TRUS-tissue interaction simulation allows a trainee to practice the 3D intraoperative TRUS placement for registration with the preoperative volume study and to practice TRUS axial translation and rotation for imaging needles during insertions. Approaches to computational acceleration for realtime haptic performance are presented. Trade-offs between accuracy and speed are discussed. A graphics-card implementation of the numerically intensive mesh-adaptation operation is also presented. The simulator can be used for training, rehearsal, and treatment planning.

DOI: 10.1109/TOH.2011.34
PubMed: 26963486

Links to Exploration step

pubmed:26963486

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.</title>
<author>
<name sortKey="Goksel, O" sort="Goksel, O" uniqKey="Goksel O" first="O" last="Goksel">O. Goksel</name>
</author>
<author>
<name sortKey="Sapchuk, K" sort="Sapchuk, K" uniqKey="Sapchuk K" first="K" last="Sapchuk">K. Sapchuk</name>
</author>
<author>
<name sortKey="Salcudean, S E" sort="Salcudean, S E" uniqKey="Salcudean S" first="S E" last="Salcudean">S E Salcudean</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>2011 May-Jun</MedlineDate>
</PubDate>
</date>
<idno type="doi">10.1109/TOH.2011.34</idno>
<idno type="RBID">pubmed:26963486</idno>
<idno type="pmid">26963486</idno>
<idno type="wicri:Area/PubMed/Corpus">000E77</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.</title>
<author>
<name sortKey="Goksel, O" sort="Goksel, O" uniqKey="Goksel O" first="O" last="Goksel">O. Goksel</name>
</author>
<author>
<name sortKey="Sapchuk, K" sort="Sapchuk, K" uniqKey="Sapchuk K" first="K" last="Sapchuk">K. Sapchuk</name>
</author>
<author>
<name sortKey="Salcudean, S E" sort="Salcudean, S E" uniqKey="Salcudean S" first="S E" last="Salcudean">S E Salcudean</name>
</author>
</analytic>
<series>
<title level="j">IEEE transactions on haptics</title>
<idno type="ISSN">1939-1412</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This paper presents a haptic simulator for prostate brachytherapy. Both needle insertion and the manipulation of the transrectal ultrasound (TRUS) probe are controlled via haptic devices. Tissue interaction forces that are computed by a deformable tissue model based on the finite element method (FEM) are rendered to the user by these devices. The needle insertion simulation employs 3D models of needle flexibility and asymmetric tip bevel. The needle-tissue simulation allows a trainee to practice needle insertion and targeting. The TRUS-tissue interaction simulation allows a trainee to practice the 3D intraoperative TRUS placement for registration with the preoperative volume study and to practice TRUS axial translation and rotation for imaging needles during insertions. Approaches to computational acceleration for realtime haptic performance are presented. Trade-offs between accuracy and speed are discussed. A graphics-card implementation of the numerically intensive mesh-adaptation operation is also presented. The simulator can be used for training, rehearsal, and treatment planning.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="PubMed-not-MEDLINE">
<PMID Version="1">26963486</PMID>
<DateCreated>
<Year>2016</Year>
<Month>03</Month>
<Day>11</Day>
</DateCreated>
<DateCompleted>
<Year>2016</Year>
<Month>03</Month>
<Day>12</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1939-1412</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>4</Volume>
<Issue>3</Issue>
<PubDate>
<MedlineDate>2011 May-Jun</MedlineDate>
</PubDate>
</JournalIssue>
<Title>IEEE transactions on haptics</Title>
<ISOAbbreviation>IEEE Trans Haptics</ISOAbbreviation>
</Journal>
<ArticleTitle>Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.</ArticleTitle>
<Pagination>
<MedlinePgn>188-98</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1109/TOH.2011.34</ELocationID>
<Abstract>
<AbstractText>This paper presents a haptic simulator for prostate brachytherapy. Both needle insertion and the manipulation of the transrectal ultrasound (TRUS) probe are controlled via haptic devices. Tissue interaction forces that are computed by a deformable tissue model based on the finite element method (FEM) are rendered to the user by these devices. The needle insertion simulation employs 3D models of needle flexibility and asymmetric tip bevel. The needle-tissue simulation allows a trainee to practice needle insertion and targeting. The TRUS-tissue interaction simulation allows a trainee to practice the 3D intraoperative TRUS placement for registration with the preoperative volume study and to practice TRUS axial translation and rotation for imaging needles during insertions. Approaches to computational acceleration for realtime haptic performance are presented. Trade-offs between accuracy and speed are discussed. A graphics-card implementation of the numerically intensive mesh-adaptation operation is also presented. The simulator can be used for training, rehearsal, and treatment planning.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Goksel</LastName>
<ForeName>O</ForeName>
<Initials>O</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Sapchuk</LastName>
<ForeName>K</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Salcudean</LastName>
<ForeName>S E</ForeName>
<Initials>SE</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>IEEE Trans Haptics</MedlineTA>
<NlmUniqueID>101491191</NlmUniqueID>
<ISSNLinking>1939-1412</ISSNLinking>
</MedlineJournalInfo>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2016</Year>
<Month>3</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2011</Year>
<Month>5</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2011</Year>
<Month>5</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1109/TOH.2011.34</ArticleId>
<ArticleId IdType="pubmed">26963486</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000E77 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000E77 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:26963486
   |texte=   Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:26963486" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024