Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.
Identifieur interne : 000E77 ( PubMed/Corpus ); précédent : 000E76; suivant : 000E78Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.
Auteurs : O. Goksel ; K. Sapchuk ; S E SalcudeanSource :
- IEEE transactions on haptics [ 1939-1412 ]
Abstract
This paper presents a haptic simulator for prostate brachytherapy. Both needle insertion and the manipulation of the transrectal ultrasound (TRUS) probe are controlled via haptic devices. Tissue interaction forces that are computed by a deformable tissue model based on the finite element method (FEM) are rendered to the user by these devices. The needle insertion simulation employs 3D models of needle flexibility and asymmetric tip bevel. The needle-tissue simulation allows a trainee to practice needle insertion and targeting. The TRUS-tissue interaction simulation allows a trainee to practice the 3D intraoperative TRUS placement for registration with the preoperative volume study and to practice TRUS axial translation and rotation for imaging needles during insertions. Approaches to computational acceleration for realtime haptic performance are presented. Trade-offs between accuracy and speed are discussed. A graphics-card implementation of the numerically intensive mesh-adaptation operation is also presented. The simulator can be used for training, rehearsal, and treatment planning.
DOI: 10.1109/TOH.2011.34
PubMed: 26963486
Links to Exploration step
pubmed:26963486Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.</title>
<author><name sortKey="Goksel, O" sort="Goksel, O" uniqKey="Goksel O" first="O" last="Goksel">O. Goksel</name>
</author>
<author><name sortKey="Sapchuk, K" sort="Sapchuk, K" uniqKey="Sapchuk K" first="K" last="Sapchuk">K. Sapchuk</name>
</author>
<author><name sortKey="Salcudean, S E" sort="Salcudean, S E" uniqKey="Salcudean S" first="S E" last="Salcudean">S E Salcudean</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="????"><PubDate><MedlineDate>2011 May-Jun</MedlineDate>
</PubDate>
</date>
<idno type="doi">10.1109/TOH.2011.34</idno>
<idno type="RBID">pubmed:26963486</idno>
<idno type="pmid">26963486</idno>
<idno type="wicri:Area/PubMed/Corpus">000E77</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.</title>
<author><name sortKey="Goksel, O" sort="Goksel, O" uniqKey="Goksel O" first="O" last="Goksel">O. Goksel</name>
</author>
<author><name sortKey="Sapchuk, K" sort="Sapchuk, K" uniqKey="Sapchuk K" first="K" last="Sapchuk">K. Sapchuk</name>
</author>
<author><name sortKey="Salcudean, S E" sort="Salcudean, S E" uniqKey="Salcudean S" first="S E" last="Salcudean">S E Salcudean</name>
</author>
</analytic>
<series><title level="j">IEEE transactions on haptics</title>
<idno type="ISSN">1939-1412</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">This paper presents a haptic simulator for prostate brachytherapy. Both needle insertion and the manipulation of the transrectal ultrasound (TRUS) probe are controlled via haptic devices. Tissue interaction forces that are computed by a deformable tissue model based on the finite element method (FEM) are rendered to the user by these devices. The needle insertion simulation employs 3D models of needle flexibility and asymmetric tip bevel. The needle-tissue simulation allows a trainee to practice needle insertion and targeting. The TRUS-tissue interaction simulation allows a trainee to practice the 3D intraoperative TRUS placement for registration with the preoperative volume study and to practice TRUS axial translation and rotation for imaging needles during insertions. Approaches to computational acceleration for realtime haptic performance are presented. Trade-offs between accuracy and speed are discussed. A graphics-card implementation of the numerically intensive mesh-adaptation operation is also presented. The simulator can be used for training, rehearsal, and treatment planning.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="PubMed-not-MEDLINE"><PMID Version="1">26963486</PMID>
<DateCreated><Year>2016</Year>
<Month>03</Month>
<Day>11</Day>
</DateCreated>
<DateCompleted><Year>2016</Year>
<Month>03</Month>
<Day>12</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">1939-1412</ISSN>
<JournalIssue CitedMedium="Print"><Volume>4</Volume>
<Issue>3</Issue>
<PubDate><MedlineDate>2011 May-Jun</MedlineDate>
</PubDate>
</JournalIssue>
<Title>IEEE transactions on haptics</Title>
<ISOAbbreviation>IEEE Trans Haptics</ISOAbbreviation>
</Journal>
<ArticleTitle>Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction.</ArticleTitle>
<Pagination><MedlinePgn>188-98</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1109/TOH.2011.34</ELocationID>
<Abstract><AbstractText>This paper presents a haptic simulator for prostate brachytherapy. Both needle insertion and the manipulation of the transrectal ultrasound (TRUS) probe are controlled via haptic devices. Tissue interaction forces that are computed by a deformable tissue model based on the finite element method (FEM) are rendered to the user by these devices. The needle insertion simulation employs 3D models of needle flexibility and asymmetric tip bevel. The needle-tissue simulation allows a trainee to practice needle insertion and targeting. The TRUS-tissue interaction simulation allows a trainee to practice the 3D intraoperative TRUS placement for registration with the preoperative volume study and to practice TRUS axial translation and rotation for imaging needles during insertions. Approaches to computational acceleration for realtime haptic performance are presented. Trade-offs between accuracy and speed are discussed. A graphics-card implementation of the numerically intensive mesh-adaptation operation is also presented. The simulator can be used for training, rehearsal, and treatment planning.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Goksel</LastName>
<ForeName>O</ForeName>
<Initials>O</Initials>
</Author>
<Author ValidYN="Y"><LastName>Sapchuk</LastName>
<ForeName>K</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y"><LastName>Salcudean</LastName>
<ForeName>S E</ForeName>
<Initials>SE</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>IEEE Trans Haptics</MedlineTA>
<NlmUniqueID>101491191</NlmUniqueID>
<ISSNLinking>1939-1412</ISSNLinking>
</MedlineJournalInfo>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2016</Year>
<Month>3</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2011</Year>
<Month>5</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2011</Year>
<Month>5</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="doi">10.1109/TOH.2011.34</ArticleId>
<ArticleId IdType="pubmed">26963486</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000E77 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000E77 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:26963486 |texte= Haptic Simulator for Prostate Brachytherapy with Simulated Needle and Probe Interaction. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:26963486" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |