Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Comparison of grasping movements made by healthy subjects in a 3-dimensional immersive virtual versus physical environment.

Identifieur interne : 000E45 ( PubMed/Corpus ); précédent : 000E44; suivant : 000E46

Comparison of grasping movements made by healthy subjects in a 3-dimensional immersive virtual versus physical environment.

Auteurs : Eliane C. Magdalon ; Stella M. Michaelsen ; Antonio A. Quevedo ; Mindy F. Levin

Source :

RBID : pubmed:21684505

English descriptors

Abstract

Virtual reality (VR) technology is being used with increasing frequency as a training medium for motor rehabilitation. However, before addressing training effectiveness in virtual environments (VEs), it is necessary to identify if movements made in such environments are kinematically similar to those made in physical environments (PEs) and the effect of provision of haptic feedback on these movement patterns. These questions are important since reach-to-grasp movements may be inaccurate when visual or haptic feedback is altered or absent. Our goal was to compare kinematics of reaching and grasping movements to three objects performed in an immersive three-dimensional (3D) VE with haptic feedback (cyberglove/grasp system) viewed through a head-mounted display to those made in an equivalent physical environment (PE). We also compared movements in PE made with and without wearing the cyberglove/grasp haptic feedback system. Ten healthy subjects (8 women, 62.1±8.8years) reached and grasped objects requiring 3 different grasp types (can, diameter 65.6mm, cylindrical grasp; screwdriver, diameter 31.6mm, power grasp; pen, diameter 7.5mm, precision grasp) in PE and visually similar virtual objects in VE. Temporal and spatial arm and trunk kinematics were analyzed. Movements were slower and grip apertures were wider when wearing the glove in both the PE and the VE compared to movements made in the PE without the glove. When wearing the glove, subjects used similar reaching trajectories in both environments, preserved the coordination between reaching and grasping and scaled grip aperture to object size for the larger object (cylindrical grasp). However, in VE compared to PE, movements were slower and had longer deceleration times, elbow extension was greater when reaching to the smallest object and apertures were wider for the power and precision grip tasks. Overall, the differences in spatial and temporal kinematics of movements between environments were greater than those due only to wearing the cyberglove/grasp system. Differences in movement kinematics due to the viewing environment were likely due to a lack of prior experience with the virtual environment, an uncertainty of object location and the restricted field-of-view when wearing the head-mounted display. The results can be used to inform the design and disposition of objects within 3D VEs for the study of the control of prehension and for upper limb rehabilitation.

DOI: 10.1016/j.actpsy.2011.05.015
PubMed: 21684505

Links to Exploration step

pubmed:21684505

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Comparison of grasping movements made by healthy subjects in a 3-dimensional immersive virtual versus physical environment.</title>
<author>
<name sortKey="Magdalon, Eliane C" sort="Magdalon, Eliane C" uniqKey="Magdalon E" first="Eliane C" last="Magdalon">Eliane C. Magdalon</name>
<affiliation>
<nlm:affiliation>Department of Biomedical Engineering, University of Campinas (UNICAMP), School of Electrical and Computer Engineering (FEEC), Campinas, SP, Brazil.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Michaelsen, Stella M" sort="Michaelsen, Stella M" uniqKey="Michaelsen S" first="Stella M" last="Michaelsen">Stella M. Michaelsen</name>
</author>
<author>
<name sortKey="Quevedo, Antonio A" sort="Quevedo, Antonio A" uniqKey="Quevedo A" first="Antonio A" last="Quevedo">Antonio A. Quevedo</name>
</author>
<author>
<name sortKey="Levin, Mindy F" sort="Levin, Mindy F" uniqKey="Levin M" first="Mindy F" last="Levin">Mindy F. Levin</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2011">2011</date>
<idno type="doi">10.1016/j.actpsy.2011.05.015</idno>
<idno type="RBID">pubmed:21684505</idno>
<idno type="pmid">21684505</idno>
<idno type="wicri:Area/PubMed/Corpus">000E45</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Comparison of grasping movements made by healthy subjects in a 3-dimensional immersive virtual versus physical environment.</title>
<author>
<name sortKey="Magdalon, Eliane C" sort="Magdalon, Eliane C" uniqKey="Magdalon E" first="Eliane C" last="Magdalon">Eliane C. Magdalon</name>
<affiliation>
<nlm:affiliation>Department of Biomedical Engineering, University of Campinas (UNICAMP), School of Electrical and Computer Engineering (FEEC), Campinas, SP, Brazil.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Michaelsen, Stella M" sort="Michaelsen, Stella M" uniqKey="Michaelsen S" first="Stella M" last="Michaelsen">Stella M. Michaelsen</name>
</author>
<author>
<name sortKey="Quevedo, Antonio A" sort="Quevedo, Antonio A" uniqKey="Quevedo A" first="Antonio A" last="Quevedo">Antonio A. Quevedo</name>
</author>
<author>
<name sortKey="Levin, Mindy F" sort="Levin, Mindy F" uniqKey="Levin M" first="Mindy F" last="Levin">Mindy F. Levin</name>
</author>
</analytic>
<series>
<title level="j">Acta psychologica</title>
<idno type="eISSN">1873-6297</idno>
<imprint>
<date when="2011" type="published">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Biomechanical Phenomena (physiology)</term>
<term>Environment</term>
<term>Female</term>
<term>Hand Strength (physiology)</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Orientation (physiology)</term>
<term>Psychomotor Performance (physiology)</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Biomechanical Phenomena</term>
<term>Hand Strength</term>
<term>Orientation</term>
<term>Psychomotor Performance</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Environment</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>User-Computer Interface</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Virtual reality (VR) technology is being used with increasing frequency as a training medium for motor rehabilitation. However, before addressing training effectiveness in virtual environments (VEs), it is necessary to identify if movements made in such environments are kinematically similar to those made in physical environments (PEs) and the effect of provision of haptic feedback on these movement patterns. These questions are important since reach-to-grasp movements may be inaccurate when visual or haptic feedback is altered or absent. Our goal was to compare kinematics of reaching and grasping movements to three objects performed in an immersive three-dimensional (3D) VE with haptic feedback (cyberglove/grasp system) viewed through a head-mounted display to those made in an equivalent physical environment (PE). We also compared movements in PE made with and without wearing the cyberglove/grasp haptic feedback system. Ten healthy subjects (8 women, 62.1±8.8years) reached and grasped objects requiring 3 different grasp types (can, diameter 65.6mm, cylindrical grasp; screwdriver, diameter 31.6mm, power grasp; pen, diameter 7.5mm, precision grasp) in PE and visually similar virtual objects in VE. Temporal and spatial arm and trunk kinematics were analyzed. Movements were slower and grip apertures were wider when wearing the glove in both the PE and the VE compared to movements made in the PE without the glove. When wearing the glove, subjects used similar reaching trajectories in both environments, preserved the coordination between reaching and grasping and scaled grip aperture to object size for the larger object (cylindrical grasp). However, in VE compared to PE, movements were slower and had longer deceleration times, elbow extension was greater when reaching to the smallest object and apertures were wider for the power and precision grip tasks. Overall, the differences in spatial and temporal kinematics of movements between environments were greater than those due only to wearing the cyberglove/grasp system. Differences in movement kinematics due to the viewing environment were likely due to a lack of prior experience with the virtual environment, an uncertainty of object location and the restricted field-of-view when wearing the head-mounted display. The results can be used to inform the design and disposition of objects within 3D VEs for the study of the control of prehension and for upper limb rehabilitation.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">21684505</PMID>
<DateCreated>
<Year>2011</Year>
<Month>09</Month>
<Day>19</Day>
</DateCreated>
<DateCompleted>
<Year>2012</Year>
<Month>01</Month>
<Day>27</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1873-6297</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>138</Volume>
<Issue>1</Issue>
<PubDate>
<Year>2011</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Acta psychologica</Title>
<ISOAbbreviation>Acta Psychol (Amst)</ISOAbbreviation>
</Journal>
<ArticleTitle>Comparison of grasping movements made by healthy subjects in a 3-dimensional immersive virtual versus physical environment.</ArticleTitle>
<Pagination>
<MedlinePgn>126-34</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.actpsy.2011.05.015</ELocationID>
<Abstract>
<AbstractText>Virtual reality (VR) technology is being used with increasing frequency as a training medium for motor rehabilitation. However, before addressing training effectiveness in virtual environments (VEs), it is necessary to identify if movements made in such environments are kinematically similar to those made in physical environments (PEs) and the effect of provision of haptic feedback on these movement patterns. These questions are important since reach-to-grasp movements may be inaccurate when visual or haptic feedback is altered or absent. Our goal was to compare kinematics of reaching and grasping movements to three objects performed in an immersive three-dimensional (3D) VE with haptic feedback (cyberglove/grasp system) viewed through a head-mounted display to those made in an equivalent physical environment (PE). We also compared movements in PE made with and without wearing the cyberglove/grasp haptic feedback system. Ten healthy subjects (8 women, 62.1±8.8years) reached and grasped objects requiring 3 different grasp types (can, diameter 65.6mm, cylindrical grasp; screwdriver, diameter 31.6mm, power grasp; pen, diameter 7.5mm, precision grasp) in PE and visually similar virtual objects in VE. Temporal and spatial arm and trunk kinematics were analyzed. Movements were slower and grip apertures were wider when wearing the glove in both the PE and the VE compared to movements made in the PE without the glove. When wearing the glove, subjects used similar reaching trajectories in both environments, preserved the coordination between reaching and grasping and scaled grip aperture to object size for the larger object (cylindrical grasp). However, in VE compared to PE, movements were slower and had longer deceleration times, elbow extension was greater when reaching to the smallest object and apertures were wider for the power and precision grip tasks. Overall, the differences in spatial and temporal kinematics of movements between environments were greater than those due only to wearing the cyberglove/grasp system. Differences in movement kinematics due to the viewing environment were likely due to a lack of prior experience with the virtual environment, an uncertainty of object location and the restricted field-of-view when wearing the head-mounted display. The results can be used to inform the design and disposition of objects within 3D VEs for the study of the control of prehension and for upper limb rehabilitation.</AbstractText>
<CopyrightInformation>Copyright © 2011 Elsevier B.V. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Magdalon</LastName>
<ForeName>Eliane C</ForeName>
<Initials>EC</Initials>
<AffiliationInfo>
<Affiliation>Department of Biomedical Engineering, University of Campinas (UNICAMP), School of Electrical and Computer Engineering (FEEC), Campinas, SP, Brazil.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Michaelsen</LastName>
<ForeName>Stella M</ForeName>
<Initials>SM</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Quevedo</LastName>
<ForeName>Antonio A</ForeName>
<Initials>AA</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Levin</LastName>
<ForeName>Mindy F</ForeName>
<Initials>MF</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Netherlands</Country>
<MedlineTA>Acta Psychol (Amst)</MedlineTA>
<NlmUniqueID>0370366</NlmUniqueID>
<ISSNLinking>0001-6918</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001696">Biomechanical Phenomena</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D004777">Environment</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D018737">Hand Strength</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009949">Orientation</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011597">Psychomotor Performance</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014584">User-Computer Interface</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2010</Year>
<Month>8</Month>
<Day>13</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised">
<Year>2011</Year>
<Month>5</Month>
<Day>21</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2011</Year>
<Month>5</Month>
<Day>23</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2011</Year>
<Month>6</Month>
<Day>21</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2011</Year>
<Month>6</Month>
<Day>21</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2012</Year>
<Month>1</Month>
<Day>28</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0001-6918(11)00109-0</ArticleId>
<ArticleId IdType="doi">10.1016/j.actpsy.2011.05.015</ArticleId>
<ArticleId IdType="pubmed">21684505</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000E45 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000E45 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:21684505
   |texte=   Comparison of grasping movements made by healthy subjects in a 3-dimensional immersive virtual versus physical environment.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:21684505" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024