Characterization of an air jet haptic lump display.
Identifieur interne : 000D14 ( PubMed/Corpus ); précédent : 000D13; suivant : 000D15Characterization of an air jet haptic lump display.
Auteurs : Matteo Bianchi ; James C. Gwilliam ; Alperen Degirmenci ; Allison M. OkamuraSource :
- Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference [ 1557-170X ] ; 2011.
English descriptors
- KwdEn :
- MESH :
Abstract
During manual palpation, clinicians rely on distributed tactile information to identify and localize hard lumps embedded in soft tissue. The development of tactile feedback systems to enhance palpation using robot-assisted minimally invasive surgery (RMIS) systems is challenging due to size and weight constraints, motivating a pneumatic actuation strategy. Recently, an air jet approach has been proposed for generating a lump percept. We use this technique to direct a thin stream of air through an aperture directly on the finger pad, which indents the skin in a hemispherical manner, producing a compelling lump percept. We hypothesize that the perceived parameters of the lump (e.g. size and stiffness) can be controlled by jointly adjusting air pressure and the aperture size through which air escapes. In this work, we investigate how these control variables interact to affect perceived pressure on the finger pad. First, we used a capacitive tactile sensor array to measure the effect of aperture size on output pressure, and found that peak output pressure increases with aperture size. Second, we performed a psychophysical experiment for each aperture size to determine the just noticeable difference (JND) of air pressure on the finger pad. Subject-averaged pressure JND values ranged from 19.4-24.7 kPa, with no statistical differences observed between aperture sizes. The aperture-pressure relationship and the pressure JND values will be fundamental for future display control.
DOI: 10.1109/IEMBS.2011.6090937
PubMed: 22255086
Links to Exploration step
pubmed:22255086Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Characterization of an air jet haptic lump display.</title>
<author><name sortKey="Bianchi, Matteo" sort="Bianchi, Matteo" uniqKey="Bianchi M" first="Matteo" last="Bianchi">Matteo Bianchi</name>
<affiliation><nlm:affiliation>Interdepartmental Research Center E Piaggio, University of Pisa, via Diotisalvi 2, 56126 Pisa, Italy. matteo.bianchi@centropiaggio.unipi.it</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Gwilliam, James C" sort="Gwilliam, James C" uniqKey="Gwilliam J" first="James C" last="Gwilliam">James C. Gwilliam</name>
</author>
<author><name sortKey="Degirmenci, Alperen" sort="Degirmenci, Alperen" uniqKey="Degirmenci A" first="Alperen" last="Degirmenci">Alperen Degirmenci</name>
</author>
<author><name sortKey="Okamura, Allison M" sort="Okamura, Allison M" uniqKey="Okamura A" first="Allison M" last="Okamura">Allison M. Okamura</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2011">2011</date>
<idno type="doi">10.1109/IEMBS.2011.6090937</idno>
<idno type="RBID">pubmed:22255086</idno>
<idno type="pmid">22255086</idno>
<idno type="wicri:Area/PubMed/Corpus">000D14</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Characterization of an air jet haptic lump display.</title>
<author><name sortKey="Bianchi, Matteo" sort="Bianchi, Matteo" uniqKey="Bianchi M" first="Matteo" last="Bianchi">Matteo Bianchi</name>
<affiliation><nlm:affiliation>Interdepartmental Research Center E Piaggio, University of Pisa, via Diotisalvi 2, 56126 Pisa, Italy. matteo.bianchi@centropiaggio.unipi.it</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Gwilliam, James C" sort="Gwilliam, James C" uniqKey="Gwilliam J" first="James C" last="Gwilliam">James C. Gwilliam</name>
</author>
<author><name sortKey="Degirmenci, Alperen" sort="Degirmenci, Alperen" uniqKey="Degirmenci A" first="Alperen" last="Degirmenci">Alperen Degirmenci</name>
</author>
<author><name sortKey="Okamura, Allison M" sort="Okamura, Allison M" uniqKey="Okamura A" first="Allison M" last="Okamura">Allison M. Okamura</name>
</author>
</analytic>
<series><title level="j">Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference</title>
<idno type="ISSN">1557-170X</idno>
<imprint><date when="2011" type="published">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Air</term>
<term>Humans</term>
<term>Psychophysics</term>
<term>Robotics</term>
<term>Skin (anatomy & histology)</term>
<term>Touch</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomy & histology" xml:lang="en"><term>Skin</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Air</term>
<term>Humans</term>
<term>Psychophysics</term>
<term>Robotics</term>
<term>Touch</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">During manual palpation, clinicians rely on distributed tactile information to identify and localize hard lumps embedded in soft tissue. The development of tactile feedback systems to enhance palpation using robot-assisted minimally invasive surgery (RMIS) systems is challenging due to size and weight constraints, motivating a pneumatic actuation strategy. Recently, an air jet approach has been proposed for generating a lump percept. We use this technique to direct a thin stream of air through an aperture directly on the finger pad, which indents the skin in a hemispherical manner, producing a compelling lump percept. We hypothesize that the perceived parameters of the lump (e.g. size and stiffness) can be controlled by jointly adjusting air pressure and the aperture size through which air escapes. In this work, we investigate how these control variables interact to affect perceived pressure on the finger pad. First, we used a capacitive tactile sensor array to measure the effect of aperture size on output pressure, and found that peak output pressure increases with aperture size. Second, we performed a psychophysical experiment for each aperture size to determine the just noticeable difference (JND) of air pressure on the finger pad. Subject-averaged pressure JND values ranged from 19.4-24.7 kPa, with no statistical differences observed between aperture sizes. The aperture-pressure relationship and the pressure JND values will be fundamental for future display control.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">22255086</PMID>
<DateCreated><Year>2012</Year>
<Month>01</Month>
<Day>18</Day>
</DateCreated>
<DateCompleted><Year>2012</Year>
<Month>06</Month>
<Day>20</Day>
</DateCompleted>
<DateRevised><Year>2014</Year>
<Month>08</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">1557-170X</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>2011</Volume>
<PubDate><Year>2011</Year>
</PubDate>
</JournalIssue>
<Title>Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference</Title>
<ISOAbbreviation>Conf Proc IEEE Eng Med Biol Soc</ISOAbbreviation>
</Journal>
<ArticleTitle>Characterization of an air jet haptic lump display.</ArticleTitle>
<Pagination><MedlinePgn>3467-70</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1109/IEMBS.2011.6090937</ELocationID>
<Abstract><AbstractText>During manual palpation, clinicians rely on distributed tactile information to identify and localize hard lumps embedded in soft tissue. The development of tactile feedback systems to enhance palpation using robot-assisted minimally invasive surgery (RMIS) systems is challenging due to size and weight constraints, motivating a pneumatic actuation strategy. Recently, an air jet approach has been proposed for generating a lump percept. We use this technique to direct a thin stream of air through an aperture directly on the finger pad, which indents the skin in a hemispherical manner, producing a compelling lump percept. We hypothesize that the perceived parameters of the lump (e.g. size and stiffness) can be controlled by jointly adjusting air pressure and the aperture size through which air escapes. In this work, we investigate how these control variables interact to affect perceived pressure on the finger pad. First, we used a capacitive tactile sensor array to measure the effect of aperture size on output pressure, and found that peak output pressure increases with aperture size. Second, we performed a psychophysical experiment for each aperture size to determine the just noticeable difference (JND) of air pressure on the finger pad. Subject-averaged pressure JND values ranged from 19.4-24.7 kPa, with no statistical differences observed between aperture sizes. The aperture-pressure relationship and the pressure JND values will be fundamental for future display control.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Bianchi</LastName>
<ForeName>Matteo</ForeName>
<Initials>M</Initials>
<AffiliationInfo><Affiliation>Interdepartmental Research Center E Piaggio, University of Pisa, via Diotisalvi 2, 56126 Pisa, Italy. matteo.bianchi@centropiaggio.unipi.it</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Gwilliam</LastName>
<ForeName>James C</ForeName>
<Initials>JC</Initials>
</Author>
<Author ValidYN="Y"><LastName>Degirmenci</LastName>
<ForeName>Alperen</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y"><LastName>Okamura</LastName>
<ForeName>Allison M</ForeName>
<Initials>AM</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
<PublicationType UI="D013486">Research Support, U.S. Gov't, Non-P.H.S.</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Conf Proc IEEE Eng Med Biol Soc</MedlineTA>
<NlmUniqueID>101243413</NlmUniqueID>
<ISSNLinking>1557-170X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="Y" UI="D000388">Air</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011601">Psychophysics</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012371">Robotics</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012867">Skin</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000033">anatomy & histology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014110">Touch</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2012</Year>
<Month>1</Month>
<Day>19</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2012</Year>
<Month>1</Month>
<Day>19</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2012</Year>
<Month>6</Month>
<Day>21</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="doi">10.1109/IEMBS.2011.6090937</ArticleId>
<ArticleId IdType="pubmed">22255086</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000D14 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000D14 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:22255086 |texte= Characterization of an air jet haptic lump display. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:22255086" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |