[Iritis with destabilization of the intraocular pressure due to dislocation of a posterior chamber intraocular lens].

Identifieur interne : 000C38 ( PubMed/Corpus ); précédent : 000C37; suivant : 000C39

[Iritis with destabilization of the intraocular pressure due to dislocation of a posterior chamber intraocular lens].

Auteurs : D M Handzel

Source :

RBID : pubmed:22415453

English descriptors

Abstract

This report concerns the case of a 67-year-old male patient who underwent uncomplicated phacoemulsification with implantation of a posterior chamber intraocular lens (IOL). After an interval of 2 months the patient developed iritis together with an uncontrollable increase in intraocular pressure. After a detailed examination a dislocated haptic of the IOL was identified as the cause of the symptoms. The dislocation had led to uveitis-glaucoma-hyphema syndrome although no hemorrhage was observed. In addition to this complication the haptic had arroded the zonular complex which made implantation of an anterior chamber lens necessary. Although improvements in operating techniques, lens materials and designs have been made uveitis-glaucoma-hyphema syndrome has to be kept in mind. Surgical intervention is the only therapeutic option.

DOI: 10.1007/s00347-011-2512-9
PubMed: 22415453

Links to Exploration step

pubmed:22415453

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Iritis with destabilization of the intraocular pressure due to dislocation of a posterior chamber intraocular lens].</title>
<author>
<name sortKey="Handzel, D M" sort="Handzel, D M" uniqKey="Handzel D" first="D M" last="Handzel">D M Handzel</name>
<affiliation>
<nlm:affiliation>Augenärztliches Operationszentrum AOZ, Marktstr. 8, 36037, Fulda, Deutschland. dhandzel@augenaerzte-fulda.de</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="doi">10.1007/s00347-011-2512-9</idno>
<idno type="RBID">pubmed:22415453</idno>
<idno type="pmid">22415453</idno>
<idno type="wicri:Area/PubMed/Corpus">000C38</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Iritis with destabilization of the intraocular pressure due to dislocation of a posterior chamber intraocular lens].</title>
<author>
<name sortKey="Handzel, D M" sort="Handzel, D M" uniqKey="Handzel D" first="D M" last="Handzel">D M Handzel</name>
<affiliation>
<nlm:affiliation>Augenärztliches Operationszentrum AOZ, Marktstr. 8, 36037, Fulda, Deutschland. dhandzel@augenaerzte-fulda.de</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</title>
<idno type="eISSN">1433-0423</idno>
<imprint>
<date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Device Removal</term>
<term>Eye Foreign Bodies (etiology)</term>
<term>Eye Foreign Bodies (surgery)</term>
<term>Humans</term>
<term>Iritis (etiology)</term>
<term>Iritis (surgery)</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Ocular Hypertension (etiology)</term>
<term>Ocular Hypertension (surgery)</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Eye Foreign Bodies</term>
<term>Iritis</term>
<term>Ocular Hypertension</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Eye Foreign Bodies</term>
<term>Iritis</term>
<term>Ocular Hypertension</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Device Removal</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Treatment Outcome</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This report concerns the case of a 67-year-old male patient who underwent uncomplicated phacoemulsification with implantation of a posterior chamber intraocular lens (IOL). After an interval of 2 months the patient developed iritis together with an uncontrollable increase in intraocular pressure. After a detailed examination a dislocated haptic of the IOL was identified as the cause of the symptoms. The dislocation had led to uveitis-glaucoma-hyphema syndrome although no hemorrhage was observed. In addition to this complication the haptic had arroded the zonular complex which made implantation of an anterior chamber lens necessary. Although improvements in operating techniques, lens materials and designs have been made uveitis-glaucoma-hyphema syndrome has to be kept in mind. Surgical intervention is the only therapeutic option.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">22415453</PMID>
<DateCreated>
<Year>2012</Year>
<Month>04</Month>
<Day>24</Day>
</DateCreated>
<DateCompleted>
<Year>2012</Year>
<Month>08</Month>
<Day>24</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1433-0423</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>109</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2012</Year>
<Month>Apr</Month>
</PubDate>
</JournalIssue>
<Title>Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</Title>
<ISOAbbreviation>Ophthalmologe</ISOAbbreviation>
</Journal>
<ArticleTitle>[Iritis with destabilization of the intraocular pressure due to dislocation of a posterior chamber intraocular lens].</ArticleTitle>
<Pagination>
<MedlinePgn>385-7</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1007/s00347-011-2512-9</ELocationID>
<Abstract>
<AbstractText>This report concerns the case of a 67-year-old male patient who underwent uncomplicated phacoemulsification with implantation of a posterior chamber intraocular lens (IOL). After an interval of 2 months the patient developed iritis together with an uncontrollable increase in intraocular pressure. After a detailed examination a dislocated haptic of the IOL was identified as the cause of the symptoms. The dislocation had led to uveitis-glaucoma-hyphema syndrome although no hemorrhage was observed. In addition to this complication the haptic had arroded the zonular complex which made implantation of an anterior chamber lens necessary. Although improvements in operating techniques, lens materials and designs have been made uveitis-glaucoma-hyphema syndrome has to be kept in mind. Surgical intervention is the only therapeutic option.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Handzel</LastName>
<ForeName>D M</ForeName>
<Initials>DM</Initials>
<AffiliationInfo>
<Affiliation>Augenärztliches Operationszentrum AOZ, Marktstr. 8, 36037, Fulda, Deutschland. dhandzel@augenaerzte-fulda.de</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>ger</Language>
<PublicationTypeList>
<PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Iritis mit Entgleisung des Intraokulardrucks bei Dislokation der Hinterkammerlinse.</VernacularTitle>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Ophthalmologe</MedlineTA>
<NlmUniqueID>9206148</NlmUniqueID>
<ISSNLinking>0941-293X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D020878">Device Removal</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005129">Eye Foreign Bodies</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007500">Iritis</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007910">Lenses, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000009">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009798">Ocular Hypertension</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D016896">Treatment Outcome</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2012</Year>
<Month>3</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2012</Year>
<Month>3</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2012</Year>
<Month>8</Month>
<Day>25</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1007/s00347-011-2512-9</ArticleId>
<ArticleId IdType="pubmed">22415453</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000C38 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000C38 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:22415453
   |texte=   [Iritis with destabilization of the intraocular pressure due to dislocation of a posterior chamber intraocular lens].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:22415453" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024