[Comparison of optical performance and stability of five different kinds of aspheric IOLs].
Identifieur interne : 000B63 ( PubMed/Corpus ); précédent : 000B62; suivant : 000B64[Comparison of optical performance and stability of five different kinds of aspheric IOLs].
Auteurs : Xiao-Jie Xing ; Xin Tang ; Hui SongSource :
- [Zhonghua yan ke za zhi] Chinese journal of ophthalmology [ 0412-4081 ] ; 2012.
English descriptors
- KwdEn :
- MESH :
Abstract
To compare the optical performance and stability of different kinds of aspheric IOLs.
PubMed: 22800448
Links to Exploration step
pubmed:22800448Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">[Comparison of optical performance and stability of five different kinds of aspheric IOLs].</title>
<author><name sortKey="Xing, Xiao Jie" sort="Xing, Xiao Jie" uniqKey="Xing X" first="Xiao-Jie" last="Xing">Xiao-Jie Xing</name>
<affiliation><nlm:affiliation>Clinical College of Ophthalmology of Tianjin Medical University, Tianjin 300020, China.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Tang, Xin" sort="Tang, Xin" uniqKey="Tang X" first="Xin" last="Tang">Xin Tang</name>
</author>
<author><name sortKey="Song, Hui" sort="Song, Hui" uniqKey="Song H" first="Hui" last="Song">Hui Song</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:22800448</idno>
<idno type="pmid">22800448</idno>
<idno type="wicri:Area/PubMed/Corpus">000B63</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">[Comparison of optical performance and stability of five different kinds of aspheric IOLs].</title>
<author><name sortKey="Xing, Xiao Jie" sort="Xing, Xiao Jie" uniqKey="Xing X" first="Xiao-Jie" last="Xing">Xiao-Jie Xing</name>
<affiliation><nlm:affiliation>Clinical College of Ophthalmology of Tianjin Medical University, Tianjin 300020, China.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Tang, Xin" sort="Tang, Xin" uniqKey="Tang X" first="Xin" last="Tang">Xin Tang</name>
</author>
<author><name sortKey="Song, Hui" sort="Song, Hui" uniqKey="Song H" first="Hui" last="Song">Hui Song</name>
</author>
</analytic>
<series><title level="j">[Zhonghua yan ke za zhi] Chinese journal of ophthalmology</title>
<idno type="ISSN">0412-4081</idno>
<imprint><date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Aged</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Materials Testing</term>
<term>Middle Aged</term>
<term>Pseudophakia</term>
<term>Retrospective Studies</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Aged</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Materials Testing</term>
<term>Middle Aged</term>
<term>Pseudophakia</term>
<term>Retrospective Studies</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To compare the optical performance and stability of different kinds of aspheric IOLs.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">22800448</PMID>
<DateCreated><Year>2012</Year>
<Month>07</Month>
<Day>17</Day>
</DateCreated>
<DateCompleted><Year>2013</Year>
<Month>04</Month>
<Day>25</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0412-4081</ISSN>
<JournalIssue CitedMedium="Print"><Volume>48</Volume>
<Issue>4</Issue>
<PubDate><Year>2012</Year>
<Month>Apr</Month>
</PubDate>
</JournalIssue>
<Title>[Zhonghua yan ke za zhi] Chinese journal of ophthalmology</Title>
<ISOAbbreviation>Zhonghua Yan Ke Za Zhi</ISOAbbreviation>
</Journal>
<ArticleTitle>[Comparison of optical performance and stability of five different kinds of aspheric IOLs].</ArticleTitle>
<Pagination><MedlinePgn>297-301</MedlinePgn>
</Pagination>
<Abstract><AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">To compare the optical performance and stability of different kinds of aspheric IOLs.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">It was a retrospective case series study. Five different kinds of aspheric IOLs were implanted into 130 eyes after cataract operation, including hydrophilic acrylic IOLs (AO, Bausch&Lomb), 25 eyes; hydrophilic acrylic IOLs (20H, Rayner), 20 eyes; 3-piece hydrophilic acrylic IOLs (PY60AD, HOYA), 30 eyes; acrylic IOLs (ZC, B00, AMO), 25 eyes; and 3-piece hydrophobic acrylic IOLs (Tecnis 9003, ZA9003, 30 eyes). Straylight on the retina was measured with C-quant. IOLs tilt and decentration were measured using Scheimpflug system (Pentacam, Oculus) and image-analysis was performed by Image-pro plus 6.0 software. Difference among groups was evaluated by analysis of variance (ANOVA). The relationship between straylight parameters and age, best corrected visual acuity (BCVA), inner HOA and MTF (HOA, high order aberration; MTF, Modulation Transfer Function) at different spatial frequencies was evaluated by Pearson correlation analysis.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The mean C-quant measurements for AO, 920H, PY60AD, ZCB00 and ZA9003 groups were 1.33 ± 0.69, 1.43 ± 0.57, 1.56 ± 0.43, 1.61 ± 0.56 and 1.71 ± 0.72, respectively, which showed no statistically significant differences (F = 0.593;P = 0.669). The straylight values in AO and 920H groups were significantly lower than that of ZCB00 and ZA9003 groups (t = 2.159, 3.271 and 2.286; P = 0.045, 0.013, and 0.046). The mean IOL decentration and tilt measurements in the 5 different groups showed no statistically significant differences (F = 4.016, 3.985; P = 0.056, 0.064).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">There are no significant difference in straylight between 5 different types of aspheric IOL implanted within the lens capsules. All of them show satisfy stability. One-piece design and hydrophilic material IOLs provide better optical performance than that of 3-piece 2-point haptic design.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Xing</LastName>
<ForeName>Xiao-jie</ForeName>
<Initials>XJ</Initials>
<AffiliationInfo><Affiliation>Clinical College of Ophthalmology of Tianjin Medical University, Tianjin 300020, China.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Tang</LastName>
<ForeName>Xin</ForeName>
<Initials>X</Initials>
</Author>
<Author ValidYN="Y"><LastName>Song</LastName>
<ForeName>Hui</ForeName>
<Initials>H</Initials>
</Author>
</AuthorList>
<Language>chi</Language>
<PublicationTypeList><PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>China</Country>
<MedlineTA>Zhonghua Yan Ke Za Zhi</MedlineTA>
<NlmUniqueID>16210540R</NlmUniqueID>
<ISSNLinking>0412-4081</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D008422">Materials Testing</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D019591">Pseudophakia</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012189">Retrospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D016896">Treatment Outcome</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2012</Year>
<Month>7</Month>
<Day>18</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2012</Year>
<Month>7</Month>
<Day>18</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2013</Year>
<Month>4</Month>
<Day>26</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">22800448</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000B63 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000B63 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:22800448 |texte= [Comparison of optical performance and stability of five different kinds of aspheric IOLs]. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:22800448" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |