Power prediction for one-piece and three-piece intraocular lens implantation after cataract surgery in patients with chronic angle-closure glaucoma: a prospective, randomized clinical trial.
Identifieur interne : 000B32 ( PubMed/Corpus ); précédent : 000B31; suivant : 000B33Power prediction for one-piece and three-piece intraocular lens implantation after cataract surgery in patients with chronic angle-closure glaucoma: a prospective, randomized clinical trial.
Auteurs : Soolienah Rhiu ; Eun Suk Lee ; Tae-Im Kim ; Hye Sun Lee ; Chan Yun KimSource :
- Acta ophthalmologica [ 1755-3768 ] ; 2012.
English descriptors
- KwdEn :
- Aged, Aged, 80 and over, Algorithms, Biometry, Cataract (complications), Chronic Disease, Female, Glaucoma, Angle-Closure (complications), Humans, Intraocular Pressure (physiology), Lens Implantation, Intraocular, Lenses, Intraocular, Male, Middle Aged, Optics and Photonics, Phacoemulsification, Prospective Studies, Prosthesis Design, Refraction, Ocular (physiology), Reproducibility of Results, Tonometry, Ocular, Visual Acuity (physiology).
- MESH :
- complications : Cataract, Glaucoma, Angle-Closure.
- physiology : Intraocular Pressure, Refraction, Ocular, Visual Acuity.
- Aged, Aged, 80 and over, Algorithms, Biometry, Chronic Disease, Female, Humans, Lens Implantation, Intraocular, Lenses, Intraocular, Male, Middle Aged, Optics and Photonics, Phacoemulsification, Prospective Studies, Prosthesis Design, Reproducibility of Results, Tonometry, Ocular.
Abstract
To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery in chronic angle-closure glaucoma (CACG) patients with different IOLs' implantation.
DOI: 10.1111/j.1755-3768.2012.02499.x
PubMed: 22971184
Links to Exploration step
pubmed:22971184Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Power prediction for one-piece and three-piece intraocular lens implantation after cataract surgery in patients with chronic angle-closure glaucoma: a prospective, randomized clinical trial.</title>
<author><name sortKey="Rhiu, Soolienah" sort="Rhiu, Soolienah" uniqKey="Rhiu S" first="Soolienah" last="Rhiu">Soolienah Rhiu</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, The Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea Seran Eye Center, Seoul, Korea.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Lee, Eun Suk" sort="Lee, Eun Suk" uniqKey="Lee E" first="Eun Suk" last="Lee">Eun Suk Lee</name>
</author>
<author><name sortKey="Kim, Tae Im" sort="Kim, Tae Im" uniqKey="Kim T" first="Tae-Im" last="Kim">Tae-Im Kim</name>
</author>
<author><name sortKey="Lee, Hye Sun" sort="Lee, Hye Sun" uniqKey="Lee H" first="Hye Sun" last="Lee">Hye Sun Lee</name>
</author>
<author><name sortKey="Kim, Chan Yun" sort="Kim, Chan Yun" uniqKey="Kim C" first="Chan Yun" last="Kim">Chan Yun Kim</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="doi">10.1111/j.1755-3768.2012.02499.x</idno>
<idno type="RBID">pubmed:22971184</idno>
<idno type="pmid">22971184</idno>
<idno type="wicri:Area/PubMed/Corpus">000B32</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Power prediction for one-piece and three-piece intraocular lens implantation after cataract surgery in patients with chronic angle-closure glaucoma: a prospective, randomized clinical trial.</title>
<author><name sortKey="Rhiu, Soolienah" sort="Rhiu, Soolienah" uniqKey="Rhiu S" first="Soolienah" last="Rhiu">Soolienah Rhiu</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, The Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea Seran Eye Center, Seoul, Korea.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Lee, Eun Suk" sort="Lee, Eun Suk" uniqKey="Lee E" first="Eun Suk" last="Lee">Eun Suk Lee</name>
</author>
<author><name sortKey="Kim, Tae Im" sort="Kim, Tae Im" uniqKey="Kim T" first="Tae-Im" last="Kim">Tae-Im Kim</name>
</author>
<author><name sortKey="Lee, Hye Sun" sort="Lee, Hye Sun" uniqKey="Lee H" first="Hye Sun" last="Lee">Hye Sun Lee</name>
</author>
<author><name sortKey="Kim, Chan Yun" sort="Kim, Chan Yun" uniqKey="Kim C" first="Chan Yun" last="Kim">Chan Yun Kim</name>
</author>
</analytic>
<series><title level="j">Acta ophthalmologica</title>
<idno type="eISSN">1755-3768</idno>
<imprint><date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Aged</term>
<term>Aged, 80 and over</term>
<term>Algorithms</term>
<term>Biometry</term>
<term>Cataract (complications)</term>
<term>Chronic Disease</term>
<term>Female</term>
<term>Glaucoma, Angle-Closure (complications)</term>
<term>Humans</term>
<term>Intraocular Pressure (physiology)</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Phacoemulsification</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
<term>Refraction, Ocular (physiology)</term>
<term>Reproducibility of Results</term>
<term>Tonometry, Ocular</term>
<term>Visual Acuity (physiology)</term>
</keywords>
<keywords scheme="MESH" qualifier="complications" xml:lang="en"><term>Cataract</term>
<term>Glaucoma, Angle-Closure</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en"><term>Intraocular Pressure</term>
<term>Refraction, Ocular</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Aged</term>
<term>Aged, 80 and over</term>
<term>Algorithms</term>
<term>Biometry</term>
<term>Chronic Disease</term>
<term>Female</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Phacoemulsification</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
<term>Reproducibility of Results</term>
<term>Tonometry, Ocular</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery in chronic angle-closure glaucoma (CACG) patients with different IOLs' implantation.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">22971184</PMID>
<DateCreated><Year>2012</Year>
<Month>11</Month>
<Day>30</Day>
</DateCreated>
<DateCompleted><Year>2013</Year>
<Month>03</Month>
<Day>14</Day>
</DateCompleted>
<Article PubModel="Print-Electronic"><Journal><ISSN IssnType="Electronic">1755-3768</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>90</Volume>
<Issue>8</Issue>
<PubDate><Year>2012</Year>
<Month>Dec</Month>
</PubDate>
</JournalIssue>
<Title>Acta ophthalmologica</Title>
<ISOAbbreviation>Acta Ophthalmol</ISOAbbreviation>
</Journal>
<ArticleTitle>Power prediction for one-piece and three-piece intraocular lens implantation after cataract surgery in patients with chronic angle-closure glaucoma: a prospective, randomized clinical trial.</ArticleTitle>
<Pagination><MedlinePgn>e580-5</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/j.1755-3768.2012.02499.x</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery in chronic angle-closure glaucoma (CACG) patients with different IOLs' implantation.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">This prospective randomized clinical trial included 45 eyes with CACG and 48 eyes with normal controls undergoing cataract surgery. In the CACG group, 23 eyes (51%) had three-piece IOL implantation and 22 eyes (49%) had one-piece IOL implantation. In the normal control group, 25 eyes (52%) had three-piece IOL implantation and 23 eyes (48%) had one-piece IOL implantation. Using the SRK/T formula, the mean difference between the predicted and actual postoperative spherical equivalent [mean absolute error (MAE)] was obtained and converted to natural logarithm (ln) for statistical analysis. The power of the implanted IOL was calculated to predict postoperative SE using three formulas: SRK II, Holladay II and Hoffer Q by post hoc analysis in each group. The predictive accuracy of each formula was analysed by comparing the lnMAE.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">In the one-piece IOL group, there was no difference in lnMAE between the CACG and normal control group (p = 0.314). In the three-piece IOL group, the lnMAE of the CACG group was larger than that of the normal control group (p < 0.001). The lnMAEs calculated by the SRK/T formula were more accurate than the Holladay II (p = 0.045) and Hoffer Q (p = 0.042) formula in the CACG one-piece IOL group.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Implantation of one-piece IOLs provides similar power prediction accuracy comparable to normal cataract patients; this result may be explained by the IOL haptic configuration or design.</AbstractText>
<CopyrightInformation>© 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Rhiu</LastName>
<ForeName>Soolienah</ForeName>
<Initials>S</Initials>
<AffiliationInfo><Affiliation>Department of Ophthalmology, The Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea Seran Eye Center, Seoul, Korea.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Lee</LastName>
<ForeName>Eun Suk</ForeName>
<Initials>ES</Initials>
</Author>
<Author ValidYN="Y"><LastName>Kim</LastName>
<ForeName>Tae-im</ForeName>
<Initials>TI</Initials>
</Author>
<Author ValidYN="Y"><LastName>Lee</LastName>
<ForeName>Hye Sun</ForeName>
<Initials>HS</Initials>
</Author>
<Author ValidYN="Y"><LastName>Kim</LastName>
<ForeName>Chan Yun</ForeName>
<Initials>CY</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D016449">Randomized Controlled Trial</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic"><Year>2012</Year>
<Month>09</Month>
<Day>12</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo><Country>England</Country>
<MedlineTA>Acta Ophthalmol</MedlineTA>
<NlmUniqueID>101468102</NlmUniqueID>
<ISSNLinking>1755-375X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000465">Algorithms</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D001699">Biometry</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D002386">Cataract</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000150">complications</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D002908">Chronic Disease</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D015812">Glaucoma, Angle-Closure</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000150">complications</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007429">Intraocular Pressure</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D055095">Optics and Photonics</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011446">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012029">Refraction, Ocular</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D015203">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014065">Tonometry, Ocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="aheadofprint"><Year>2012</Year>
<Month>9</Month>
<Day>12</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2012</Year>
<Month>9</Month>
<Day>14</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2012</Year>
<Month>9</Month>
<Day>14</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2013</Year>
<Month>3</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="doi">10.1111/j.1755-3768.2012.02499.x</ArticleId>
<ArticleId IdType="pubmed">22971184</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000B32 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000B32 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:22971184 |texte= Power prediction for one-piece and three-piece intraocular lens implantation after cataract surgery in patients with chronic angle-closure glaucoma: a prospective, randomized clinical trial. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:22971184" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |