Coaxial needle insertion assistant with enhanced force feedback.

Identifieur interne : 000A91 ( PubMed/Corpus ); précédent : 000A90; suivant : 000A92

Coaxial needle insertion assistant with enhanced force feedback.

Auteurs : Danilo De Lorenzo ; Yoshihiko Koseki ; Elena De Momi ; Kiyoyuki Chinzei ; Allison M. Okamura

Source :

RBID : pubmed:23193302

English descriptors

Abstract

Many medical procedures involving needle insertion into soft tissues, such as anesthesia, biopsy, brachytherapy, and placement of electrodes, are performed without image guidance. In such procedures, haptic detection of changing tissue properties at different depths during needle insertion is important for needle localization and detection of subsurface structures. However, changes in tissue mechanical properties deep inside the tissue are difficult for human operators to sense, because the relatively large friction force between the needle shaft and the surrounding tissue masks the smaller tip forces. A novel robotic coaxial needle insertion assistant, which enhances operator force perception, is presented. This one-degree-of-freedom cable-driven robot provides to the operator a scaled version of the force applied by the needle tip to the tissue, using a novel design and sensors that separate the needle tip force from the shaft friction force. The ability of human operators to use the robot to detect membranes embedded in artificial soft tissue was tested under the conditions of 1) tip force and shaft force feedback, and 2) tip force only feedback. The ratio of successful to unsuccessful membrane detections was significantly higher (up to 50%) when only the needle tip force was provided to the user.

DOI: 10.1109/TBME.2012.2227316
PubMed: 23193302

Links to Exploration step

pubmed:23193302

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Coaxial needle insertion assistant with enhanced force feedback.</title>
<author>
<name sortKey="De Lorenzo, Danilo" sort="De Lorenzo, Danilo" uniqKey="De Lorenzo D" first="Danilo" last="De Lorenzo">Danilo De Lorenzo</name>
<affiliation>
<nlm:affiliation>Neuroengineering and Medical Robotics Laboratory, Department of Bioengineering, Politecnico di Milano, 20133 Milano, Italy. danilo.delorenzo@mail.polimi.it</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Koseki, Yoshihiko" sort="Koseki, Yoshihiko" uniqKey="Koseki Y" first="Yoshihiko" last="Koseki">Yoshihiko Koseki</name>
</author>
<author>
<name sortKey="De Momi, Elena" sort="De Momi, Elena" uniqKey="De Momi E" first="Elena" last="De Momi">Elena De Momi</name>
</author>
<author>
<name sortKey="Chinzei, Kiyoyuki" sort="Chinzei, Kiyoyuki" uniqKey="Chinzei K" first="Kiyoyuki" last="Chinzei">Kiyoyuki Chinzei</name>
</author>
<author>
<name sortKey="Okamura, Allison M" sort="Okamura, Allison M" uniqKey="Okamura A" first="Allison M" last="Okamura">Allison M. Okamura</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="doi">10.1109/TBME.2012.2227316</idno>
<idno type="RBID">pubmed:23193302</idno>
<idno type="pmid">23193302</idno>
<idno type="wicri:Area/PubMed/Corpus">000A91</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Coaxial needle insertion assistant with enhanced force feedback.</title>
<author>
<name sortKey="De Lorenzo, Danilo" sort="De Lorenzo, Danilo" uniqKey="De Lorenzo D" first="Danilo" last="De Lorenzo">Danilo De Lorenzo</name>
<affiliation>
<nlm:affiliation>Neuroengineering and Medical Robotics Laboratory, Department of Bioengineering, Politecnico di Milano, 20133 Milano, Italy. danilo.delorenzo@mail.polimi.it</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Koseki, Yoshihiko" sort="Koseki, Yoshihiko" uniqKey="Koseki Y" first="Yoshihiko" last="Koseki">Yoshihiko Koseki</name>
</author>
<author>
<name sortKey="De Momi, Elena" sort="De Momi, Elena" uniqKey="De Momi E" first="Elena" last="De Momi">Elena De Momi</name>
</author>
<author>
<name sortKey="Chinzei, Kiyoyuki" sort="Chinzei, Kiyoyuki" uniqKey="Chinzei K" first="Kiyoyuki" last="Chinzei">Kiyoyuki Chinzei</name>
</author>
<author>
<name sortKey="Okamura, Allison M" sort="Okamura, Allison M" uniqKey="Okamura A" first="Allison M" last="Okamura">Allison M. Okamura</name>
</author>
</analytic>
<series>
<title level="j">IEEE transactions on bio-medical engineering</title>
<idno type="eISSN">1558-2531</idno>
<imprint>
<date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Biomechanical Phenomena</term>
<term>Brain (physiology)</term>
<term>Computer Simulation</term>
<term>Feedback</term>
<term>Humans</term>
<term>Minimally Invasive Surgical Procedures (instrumentation)</term>
<term>Minimally Invasive Surgical Procedures (methods)</term>
<term>Models, Biological</term>
<term>Needles</term>
<term>Pressure</term>
<term>Robotics (instrumentation)</term>
<term>Signal Processing, Computer-Assisted</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Minimally Invasive Surgical Procedures</term>
<term>Robotics</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Minimally Invasive Surgical Procedures</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Brain</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Biomechanical Phenomena</term>
<term>Computer Simulation</term>
<term>Feedback</term>
<term>Humans</term>
<term>Models, Biological</term>
<term>Needles</term>
<term>Pressure</term>
<term>Signal Processing, Computer-Assisted</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Many medical procedures involving needle insertion into soft tissues, such as anesthesia, biopsy, brachytherapy, and placement of electrodes, are performed without image guidance. In such procedures, haptic detection of changing tissue properties at different depths during needle insertion is important for needle localization and detection of subsurface structures. However, changes in tissue mechanical properties deep inside the tissue are difficult for human operators to sense, because the relatively large friction force between the needle shaft and the surrounding tissue masks the smaller tip forces. A novel robotic coaxial needle insertion assistant, which enhances operator force perception, is presented. This one-degree-of-freedom cable-driven robot provides to the operator a scaled version of the force applied by the needle tip to the tissue, using a novel design and sensors that separate the needle tip force from the shaft friction force. The ability of human operators to use the robot to detect membranes embedded in artificial soft tissue was tested under the conditions of 1) tip force and shaft force feedback, and 2) tip force only feedback. The ratio of successful to unsuccessful membrane detections was significantly higher (up to 50%) when only the needle tip force was provided to the user.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">23193302</PMID>
<DateCreated>
<Year>2013</Year>
<Month>01</Month>
<Day>21</Day>
</DateCreated>
<DateCompleted>
<Year>2013</Year>
<Month>11</Month>
<Day>18</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>11</Month>
<Day>20</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1558-2531</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>60</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2013</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>IEEE transactions on bio-medical engineering</Title>
<ISOAbbreviation>IEEE Trans Biomed Eng</ISOAbbreviation>
</Journal>
<ArticleTitle>Coaxial needle insertion assistant with enhanced force feedback.</ArticleTitle>
<Pagination>
<MedlinePgn>379-89</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1109/TBME.2012.2227316</ELocationID>
<Abstract>
<AbstractText>Many medical procedures involving needle insertion into soft tissues, such as anesthesia, biopsy, brachytherapy, and placement of electrodes, are performed without image guidance. In such procedures, haptic detection of changing tissue properties at different depths during needle insertion is important for needle localization and detection of subsurface structures. However, changes in tissue mechanical properties deep inside the tissue are difficult for human operators to sense, because the relatively large friction force between the needle shaft and the surrounding tissue masks the smaller tip forces. A novel robotic coaxial needle insertion assistant, which enhances operator force perception, is presented. This one-degree-of-freedom cable-driven robot provides to the operator a scaled version of the force applied by the needle tip to the tissue, using a novel design and sensors that separate the needle tip force from the shaft friction force. The ability of human operators to use the robot to detect membranes embedded in artificial soft tissue was tested under the conditions of 1) tip force and shaft force feedback, and 2) tip force only feedback. The ratio of successful to unsuccessful membrane detections was significantly higher (up to 50%) when only the needle tip force was provided to the user.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>De Lorenzo</LastName>
<ForeName>Danilo</ForeName>
<Initials>D</Initials>
<AffiliationInfo>
<Affiliation>Neuroengineering and Medical Robotics Laboratory, Department of Bioengineering, Politecnico di Milano, 20133 Milano, Italy. danilo.delorenzo@mail.polimi.it</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Koseki</LastName>
<ForeName>Yoshihiko</ForeName>
<Initials>Y</Initials>
</Author>
<Author ValidYN="Y">
<LastName>De Momi</LastName>
<ForeName>Elena</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Chinzei</LastName>
<ForeName>Kiyoyuki</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Okamura</LastName>
<ForeName>Allison M</ForeName>
<Initials>AM</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<GrantList CompleteYN="Y">
<Grant>
<GrantID>R01 EB006435</GrantID>
<Acronym>EB</Acronym>
<Agency>NIBIB NIH HHS</Agency>
<Country>United States</Country>
</Grant>
</GrantList>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D052061">Research Support, N.I.H., Extramural</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2012</Year>
<Month>11</Month>
<Day>15</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>IEEE Trans Biomed Eng</MedlineTA>
<NlmUniqueID>0012737</NlmUniqueID>
<ISSNLinking>0018-9294</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001696">Biomechanical Phenomena</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001921">Brain</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003198">Computer Simulation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005246">Feedback</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019060">Minimally Invasive Surgical Procedures</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008954">Models, Biological</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D009339">Needles</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011312">Pressure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012371">Robotics</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D012815">Signal Processing, Computer-Assisted</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D025321">Surgery, Computer-Assisted</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="aheadofprint">
<Year>2012</Year>
<Month>11</Month>
<Day>15</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2012</Year>
<Month>11</Month>
<Day>30</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2012</Year>
<Month>11</Month>
<Day>30</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2013</Year>
<Month>11</Month>
<Day>19</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1109/TBME.2012.2227316</ArticleId>
<ArticleId IdType="pubmed">23193302</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000A91 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000A91 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:23193302
   |texte=   Coaxial needle insertion assistant with enhanced force feedback.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:23193302" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024