Modification of externalized haptic support of glued intraocular lens technique.
Identifieur interne : 000994 ( PubMed/Corpus ); précédent : 000993; suivant : 000995Modification of externalized haptic support of glued intraocular lens technique.
Auteurs : George Beiko ; Roger SteinertSource :
- Journal of cataract and refractive surgery [ 1873-4502 ] ; 2013.
English descriptors
- KwdEn :
- MESH :
- chemical , therapeutic use : Fibrin Tissue Adhesive, Tissue Adhesives.
- drug effects : Sclera.
- methods : Lens Implantation, Intraocular.
- Cataract Extraction, Humans, Lenses, Intraocular.
Abstract
The original technique for scleral fixation of an intraocular lens using fibrin glue requires an assistant to grasp and hold an externalized haptic with forceps. We present a modification of the technique in which the externalized haptic is maintained by a silicone "tire" without the aid of an assistant.
DOI: 10.1016/j.jcrs.2013.01.017
PubMed: 23506915
Links to Exploration step
pubmed:23506915Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Modification of externalized haptic support of glued intraocular lens technique.</title>
<author><name sortKey="Beiko, George" sort="Beiko, George" uniqKey="Beiko G" first="George" last="Beiko">George Beiko</name>
<affiliation><nlm:affiliation>McMaster University, Saint Catharines, Ontario, Canada. george.beiko@sympatico.ca</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Steinert, Roger" sort="Steinert, Roger" uniqKey="Steinert R" first="Roger" last="Steinert">Roger Steinert</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="doi">10.1016/j.jcrs.2013.01.017</idno>
<idno type="RBID">pubmed:23506915</idno>
<idno type="pmid">23506915</idno>
<idno type="wicri:Area/PubMed/Corpus">000994</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Modification of externalized haptic support of glued intraocular lens technique.</title>
<author><name sortKey="Beiko, George" sort="Beiko, George" uniqKey="Beiko G" first="George" last="Beiko">George Beiko</name>
<affiliation><nlm:affiliation>McMaster University, Saint Catharines, Ontario, Canada. george.beiko@sympatico.ca</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Steinert, Roger" sort="Steinert, Roger" uniqKey="Steinert R" first="Roger" last="Steinert">Roger Steinert</name>
</author>
</analytic>
<series><title level="j">Journal of cataract and refractive surgery</title>
<idno type="eISSN">1873-4502</idno>
<imprint><date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Cataract Extraction</term>
<term>Fibrin Tissue Adhesive (therapeutic use)</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Sclera (drug effects)</term>
<term>Tissue Adhesives (therapeutic use)</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="therapeutic use" xml:lang="en"><term>Fibrin Tissue Adhesive</term>
<term>Tissue Adhesives</term>
</keywords>
<keywords scheme="MESH" qualifier="drug effects" xml:lang="en"><term>Sclera</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Cataract Extraction</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The original technique for scleral fixation of an intraocular lens using fibrin glue requires an assistant to grasp and hold an externalized haptic with forceps. We present a modification of the technique in which the externalized haptic is maintained by a silicone "tire" without the aid of an assistant.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">23506915</PMID>
<DateCreated><Year>2013</Year>
<Month>03</Month>
<Day>19</Day>
</DateCreated>
<DateCompleted><Year>2013</Year>
<Month>08</Month>
<Day>14</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Electronic">1873-4502</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>39</Volume>
<Issue>3</Issue>
<PubDate><Year>2013</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Modification of externalized haptic support of glued intraocular lens technique.</ArticleTitle>
<Pagination><MedlinePgn>323-5</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.jcrs.2013.01.017</ELocationID>
<ELocationID EIdType="pii" ValidYN="Y">S0886-3350(13)00028-X</ELocationID>
<Abstract><AbstractText>The original technique for scleral fixation of an intraocular lens using fibrin glue requires an assistant to grasp and hold an externalized haptic with forceps. We present a modification of the technique in which the externalized haptic is maintained by a silicone "tire" without the aid of an assistant.</AbstractText>
<CopyrightInformation>Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Beiko</LastName>
<ForeName>George</ForeName>
<Initials>G</Initials>
<AffiliationInfo><Affiliation>McMaster University, Saint Catharines, Ontario, Canada. george.beiko@sympatico.ca</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Steinert</LastName>
<ForeName>Roger</ForeName>
<Initials>R</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015718">Fibrin Tissue Adhesive</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D014014">Tissue Adhesives</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="Y" UI="D002387">Cataract Extraction</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D015718">Fibrin Tissue Adhesive</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000627">therapeutic use</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D012590">Sclera</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000187">drug effects</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014014">Tissue Adhesives</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000627">therapeutic use</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="received"><Year>2012</Year>
<Month>9</Month>
<Day>14</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised"><Year>2012</Year>
<Month>10</Month>
<Day>22</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted"><Year>2012</Year>
<Month>10</Month>
<Day>29</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2013</Year>
<Month>3</Month>
<Day>20</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2013</Year>
<Month>3</Month>
<Day>20</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2013</Year>
<Month>8</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pii">S0886-3350(13)00028-X</ArticleId>
<ArticleId IdType="doi">10.1016/j.jcrs.2013.01.017</ArticleId>
<ArticleId IdType="pubmed">23506915</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000994 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000994 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:23506915 |texte= Modification of externalized haptic support of glued intraocular lens technique. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:23506915" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |