Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: a case report.

Identifieur interne : 000968 ( PubMed/Corpus ); précédent : 000967; suivant : 000969

Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: a case report.

Auteurs : Haemin Kang ; Kyung Eun Han ; Tae-Im Kim ; Eung Kweon Kim

Source :

RBID : pubmed:23619497

English descriptors

Abstract

A 57-year-old male patient visited our clinic for decreased visual acuity in the right eye for 10 days. He denied any trauma history, but recalled that the symptom developed after straining. He had undergone uncomplicated phacoemulsification and posterior chamber intraocular lens (IOL) implantation in the bag of the right eye 11 years ago. The IOL was a three-piece silicone polyimide-haptics design. On slit-lamp examination, the IOL optic and proximal part of nasal fractured haptic were found in the anterior chamber. The distal part of fractured haptic was observed in the capsular bag. He underwent IOL exchange. The fracture site of the haptic was near the optic-haptic junction. This is the unique case report of a spontaneous fracture of an implanted posterior chamber polyimide IOL haptic, which implies the possibility of IOL haptic fracture in various haptic materials.

DOI: 10.4103/0301-4738.111195
PubMed: 23619497

Links to Exploration step

pubmed:23619497

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: a case report.</title>
<author>
<name sortKey="Kang, Haemin" sort="Kang, Haemin" uniqKey="Kang H" first="Haemin" last="Kang">Haemin Kang</name>
</author>
<author>
<name sortKey="Han, Kyung Eun" sort="Han, Kyung Eun" uniqKey="Han K" first="Kyung Eun" last="Han">Kyung Eun Han</name>
</author>
<author>
<name sortKey="Kim, Tae Im" sort="Kim, Tae Im" uniqKey="Kim T" first="Tae-Im" last="Kim">Tae-Im Kim</name>
</author>
<author>
<name sortKey="Kim, Eung Kweon" sort="Kim, Eung Kweon" uniqKey="Kim E" first="Eung Kweon" last="Kim">Eung Kweon Kim</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology; Corneal Dystrophy Research Institute; Severance Biomedical Science Institute; Brain Korea 21 Project for Medical Science, Yonsei University College of Medicine, Seoul, Korea.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="doi">10.4103/0301-4738.111195</idno>
<idno type="RBID">pubmed:23619497</idno>
<idno type="pmid">23619497</idno>
<idno type="wicri:Area/PubMed/Corpus">000968</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: a case report.</title>
<author>
<name sortKey="Kang, Haemin" sort="Kang, Haemin" uniqKey="Kang H" first="Haemin" last="Kang">Haemin Kang</name>
</author>
<author>
<name sortKey="Han, Kyung Eun" sort="Han, Kyung Eun" uniqKey="Han K" first="Kyung Eun" last="Han">Kyung Eun Han</name>
</author>
<author>
<name sortKey="Kim, Tae Im" sort="Kim, Tae Im" uniqKey="Kim T" first="Tae-Im" last="Kim">Tae-Im Kim</name>
</author>
<author>
<name sortKey="Kim, Eung Kweon" sort="Kim, Eung Kweon" uniqKey="Kim E" first="Eung Kweon" last="Kim">Eung Kweon Kim</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology; Corneal Dystrophy Research Institute; Severance Biomedical Science Institute; Brain Korea 21 Project for Medical Science, Yonsei University College of Medicine, Seoul, Korea.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Indian journal of ophthalmology</title>
<idno type="eISSN">1998-3689</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Device Removal</term>
<term>Diagnosis, Differential</term>
<term>Eye Foreign Bodies (diagnosis)</term>
<term>Eye Foreign Bodies (etiology)</term>
<term>Eye Foreign Bodies (surgery)</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Phacoemulsification</term>
<term>Prosthesis Design</term>
<term>Prosthesis Failure</term>
<term>Resins, Synthetic</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Resins, Synthetic</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Eye Foreign Bodies</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Eye Foreign Bodies</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Eye Foreign Bodies</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Device Removal</term>
<term>Diagnosis, Differential</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Phacoemulsification</term>
<term>Prosthesis Design</term>
<term>Prosthesis Failure</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A 57-year-old male patient visited our clinic for decreased visual acuity in the right eye for 10 days. He denied any trauma history, but recalled that the symptom developed after straining. He had undergone uncomplicated phacoemulsification and posterior chamber intraocular lens (IOL) implantation in the bag of the right eye 11 years ago. The IOL was a three-piece silicone polyimide-haptics design. On slit-lamp examination, the IOL optic and proximal part of nasal fractured haptic were found in the anterior chamber. The distal part of fractured haptic was observed in the capsular bag. He underwent IOL exchange. The fracture site of the haptic was near the optic-haptic junction. This is the unique case report of a spontaneous fracture of an implanted posterior chamber polyimide IOL haptic, which implies the possibility of IOL haptic fracture in various haptic materials.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">23619497</PMID>
<DateCreated>
<Year>2014</Year>
<Month>04</Month>
<Day>11</Day>
</DateCreated>
<DateCompleted>
<Year>2015</Year>
<Month>04</Month>
<Day>13</Day>
</DateCompleted>
<DateRevised>
<Year>2015</Year>
<Month>04</Month>
<Day>27</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1998-3689</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>62</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2014</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Indian journal of ophthalmology</Title>
<ISOAbbreviation>Indian J Ophthalmol</ISOAbbreviation>
</Journal>
<ArticleTitle>Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: a case report.</ArticleTitle>
<Pagination>
<MedlinePgn>348-50</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.4103/0301-4738.111195</ELocationID>
<Abstract>
<AbstractText>A 57-year-old male patient visited our clinic for decreased visual acuity in the right eye for 10 days. He denied any trauma history, but recalled that the symptom developed after straining. He had undergone uncomplicated phacoemulsification and posterior chamber intraocular lens (IOL) implantation in the bag of the right eye 11 years ago. The IOL was a three-piece silicone polyimide-haptics design. On slit-lamp examination, the IOL optic and proximal part of nasal fractured haptic were found in the anterior chamber. The distal part of fractured haptic was observed in the capsular bag. He underwent IOL exchange. The fracture site of the haptic was near the optic-haptic junction. This is the unique case report of a spontaneous fracture of an implanted posterior chamber polyimide IOL haptic, which implies the possibility of IOL haptic fracture in various haptic materials.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Kang</LastName>
<ForeName>Haemin</ForeName>
<Initials>H</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Han</LastName>
<ForeName>Kyung Eun</ForeName>
<Initials>KE</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Kim</LastName>
<ForeName>Tae-im</ForeName>
<Initials>TI</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Kim</LastName>
<ForeName>Eung Kweon</ForeName>
<Initials>EK</Initials>
<AffiliationInfo>
<Affiliation>Department of Ophthalmology; Corneal Dystrophy Research Institute; Severance Biomedical Science Institute; Brain Korea 21 Project for Medical Science, Yonsei University College of Medicine, Seoul, Korea.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>India</Country>
<MedlineTA>Indian J Ophthalmol</MedlineTA>
<NlmUniqueID>0405376</NlmUniqueID>
<ISSNLinking>0301-4738</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012117">Resins, Synthetic</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>39355-34-5</RegistryNumber>
<NameOfSubstance UI="C029945">polyimide resin</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<CommentsCorrectionsList>
<CommentsCorrections RefType="Cites">
<RefSource>J Cataract Refract Surg. 2001 Dec;27(12):2047-50</RefSource>
<PMID Version="1">11738925</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Cataract Refract Surg. 2002 Jul;28(7):1223-8</RefSource>
<PMID Version="1">12106732</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Am Intraocul Implant Soc. 1981 Jan;7(1):46-8</RefSource>
<PMID Version="1">7228803</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Cataract Refract Surg. 2007 Dec;33(12):2151-2</RefSource>
<PMID Version="1">18053922</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Pediatr Ophthalmol Strabismus. 1995 Jul-Aug;32(4):219-24</RefSource>
<PMID Version="1">7494156</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Cataract Refract Surg. 1997 Nov;23(9):1418-20</RefSource>
<PMID Version="1">9423919</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Eur J Ophthalmol. 2005 Jul-Aug;15(4):507-9</RefSource>
<PMID Version="1">16001387</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Cataract Refract Surg. 1987 Mar;13(2):194-7</RefSource>
<PMID Version="1">3572774</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D020878">Device Removal</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003937">Diagnosis, Differential</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005129">Eye Foreign Bodies</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000175">diagnosis</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011475">Prosthesis Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D012117">Resins, Synthetic</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<OtherID Source="NLM">PMC4061679</OtherID>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>4</Month>
<Day>27</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>4</Month>
<Day>27</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>4</Month>
<Day>14</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">111195</ArticleId>
<ArticleId IdType="doi">10.4103/0301-4738.111195</ArticleId>
<ArticleId IdType="pubmed">23619497</ArticleId>
<ArticleId IdType="pmc">PMC4061679</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000968 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000968 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:23619497
   |texte=   Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: a case report.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:23619497" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024