Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Haptic perception of multi-joint hypertonia during simulated patient-therapist physical tele-interaction.

Identifieur interne : 000842 ( PubMed/Corpus ); précédent : 000841; suivant : 000843

Haptic perception of multi-joint hypertonia during simulated patient-therapist physical tele-interaction.

Auteurs : D. Piovesan ; A. Melendez-Calderon ; F A Mussa-Ivaldi

Source :

RBID : pubmed:24110644

English descriptors

Abstract

A potential solution to provide individualized physical therapy in remote areas is tele-interaction via robotic devices. To maintain stability during tele-interaction, transmission delay-compensation algorithms bound the impedance between the patient and the therapist. This can compromise the haptic perception of the patient being assessed, which can in turn lead to a bad diagnosis or intervention. We investigated how the perception of the severity of hypertonia (a common condition after neurological disorders) varied by modifying the connection impedance on a physical simulator. We found that assessing hypetonia using a low impedance connection may result in an overestimation of mild impairments.

DOI: 10.1109/EMBC.2013.6610457
PubMed: 24110644

Links to Exploration step

pubmed:24110644

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Haptic perception of multi-joint hypertonia during simulated patient-therapist physical tele-interaction.</title>
<author>
<name sortKey="Piovesan, D" sort="Piovesan, D" uniqKey="Piovesan D" first="D" last="Piovesan">D. Piovesan</name>
</author>
<author>
<name sortKey="Melendez Calderon, A" sort="Melendez Calderon, A" uniqKey="Melendez Calderon A" first="A" last="Melendez-Calderon">A. Melendez-Calderon</name>
</author>
<author>
<name sortKey="Mussa Ivaldi, F A" sort="Mussa Ivaldi, F A" uniqKey="Mussa Ivaldi F" first="F A" last="Mussa-Ivaldi">F A Mussa-Ivaldi</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="doi">10.1109/EMBC.2013.6610457</idno>
<idno type="RBID">pubmed:24110644</idno>
<idno type="pmid">24110644</idno>
<idno type="wicri:Area/PubMed/Corpus">000842</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Haptic perception of multi-joint hypertonia during simulated patient-therapist physical tele-interaction.</title>
<author>
<name sortKey="Piovesan, D" sort="Piovesan, D" uniqKey="Piovesan D" first="D" last="Piovesan">D. Piovesan</name>
</author>
<author>
<name sortKey="Melendez Calderon, A" sort="Melendez Calderon, A" uniqKey="Melendez Calderon A" first="A" last="Melendez-Calderon">A. Melendez-Calderon</name>
</author>
<author>
<name sortKey="Mussa Ivaldi, F A" sort="Mussa Ivaldi, F A" uniqKey="Mussa Ivaldi F" first="F A" last="Mussa-Ivaldi">F A Mussa-Ivaldi</name>
</author>
</analytic>
<series>
<title level="j">Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference</title>
<idno type="ISSN">1557-170X</idno>
<imprint>
<date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Computer Simulation</term>
<term>Humans</term>
<term>Joints (physiopathology)</term>
<term>Muscle Hypertonia (physiopathology)</term>
<term>Patient Simulation</term>
<term>Physical Therapy Modalities</term>
<term>Telemetry (methods)</term>
<term>Touch Perception (physiology)</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Telemetry</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Touch Perception</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Joints</term>
<term>Muscle Hypertonia</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Computer Simulation</term>
<term>Humans</term>
<term>Patient Simulation</term>
<term>Physical Therapy Modalities</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A potential solution to provide individualized physical therapy in remote areas is tele-interaction via robotic devices. To maintain stability during tele-interaction, transmission delay-compensation algorithms bound the impedance between the patient and the therapist. This can compromise the haptic perception of the patient being assessed, which can in turn lead to a bad diagnosis or intervention. We investigated how the perception of the severity of hypertonia (a common condition after neurological disorders) varied by modifying the connection impedance on a physical simulator. We found that assessing hypetonia using a low impedance connection may result in an overestimation of mild impairments.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">24110644</PMID>
<DateCreated>
<Year>2013</Year>
<Month>10</Month>
<Day>10</Day>
</DateCreated>
<DateCompleted>
<Year>2015</Year>
<Month>07</Month>
<Day>14</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>02</Month>
<Day>29</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1557-170X</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>2013</Volume>
<PubDate>
<Year>2013</Year>
</PubDate>
</JournalIssue>
<Title>Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference</Title>
<ISOAbbreviation>Conf Proc IEEE Eng Med Biol Soc</ISOAbbreviation>
</Journal>
<ArticleTitle>Haptic perception of multi-joint hypertonia during simulated patient-therapist physical tele-interaction.</ArticleTitle>
<Pagination>
<MedlinePgn>4143-7</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1109/EMBC.2013.6610457</ELocationID>
<Abstract>
<AbstractText>A potential solution to provide individualized physical therapy in remote areas is tele-interaction via robotic devices. To maintain stability during tele-interaction, transmission delay-compensation algorithms bound the impedance between the patient and the therapist. This can compromise the haptic perception of the patient being assessed, which can in turn lead to a bad diagnosis or intervention. We investigated how the perception of the severity of hypertonia (a common condition after neurological disorders) varied by modifying the connection impedance on a physical simulator. We found that assessing hypetonia using a low impedance connection may result in an overestimation of mild impairments.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Piovesan</LastName>
<ForeName>D</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Melendez-Calderon</LastName>
<ForeName>A</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Mussa-Ivaldi</LastName>
<ForeName>F A</ForeName>
<Initials>FA</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<GrantList CompleteYN="Y">
<Grant>
<GrantID>2R01NS035673</GrantID>
<Acronym>NS</Acronym>
<Agency>NINDS NIH HHS</Agency>
<Country>United States</Country>
</Grant>
<Grant>
<GrantID>R01 NS035673</GrantID>
<Acronym>NS</Acronym>
<Agency>NINDS NIH HHS</Agency>
<Country>United States</Country>
</Grant>
</GrantList>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D052061">Research Support, N.I.H., Extramural</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Conf Proc IEEE Eng Med Biol Soc</MedlineTA>
<NlmUniqueID>101243413</NlmUniqueID>
<ISSNLinking>1557-170X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<CommentsCorrectionsList>
<CommentsCorrections RefType="Cites">
<RefSource>Eur J Appl Physiol Occup Physiol. 1996;72(4):380-2</RefSource>
<PMID Version="1">8851909</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Neurol Neurosurg Psychiatry. 1995 Sep;59(3):271-9</RefSource>
<PMID Version="1">7673955</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>IEEE Int Conf Rehabil Robot. 2013 Jun;2013:6650425</RefSource>
<PMID Version="1">24187243</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Neurol Neurosurg Psychiatry. 1986 Oct;49(10):1177-81</RefSource>
<PMID Version="1">3783179</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Physiother Res Int. 1996;1(2):75-88</RefSource>
<PMID Version="1">9238725</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Stroke. 1997 Aug;28(8):1550-6</RefSource>
<PMID Version="1">9259747</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>IEEE Trans Neural Syst Rehabil Eng. 2005 Mar;13(1):1-11</RefSource>
<PMID Version="1">15813400</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Cyberpsychol Behav. 2006 Apr;9(2):178-82</RefSource>
<PMID Version="1">16640475</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Neurosci. 2008 Oct 29;28(44):11165-73</RefSource>
<PMID Version="1">18971459</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>IEEE Trans Neural Syst Rehabil Eng. 2013 May;21(3):454-65</RefSource>
<PMID Version="1">23193322</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>IEEE Trans Neural Syst Rehabil Eng. 2012 May;20(3):361-70</RefSource>
<PMID Version="1">22562769</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Biomech. 2003 Aug;36(8):1117-24</RefSource>
<PMID Version="1">12831737</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Neurophysiol. 2009 Jul;102(1):460-74</RefSource>
<PMID Version="1">19420127</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Percept Psychophys. 1995 May;57(4):495-510</RefSource>
<PMID Version="1">7596747</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>IEEE Int Conf Rehabil Robot. 2011;2011:5975462</RefSource>
<PMID Version="1">22275660</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D003198">Computer Simulation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007596">Joints</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000503">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009122">Muscle Hypertonia</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000503">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D016544">Patient Simulation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D026741">Physical Therapy Modalities</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013686">Telemetry</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D055698">Touch Perception</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
</MeshHeadingList>
<OtherID Source="NLM">NIHMS705642</OtherID>
<OtherID Source="NLM">PMC4498567</OtherID>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>10</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>10</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>7</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1109/EMBC.2013.6610457</ArticleId>
<ArticleId IdType="pubmed">24110644</ArticleId>
<ArticleId IdType="pmc">PMC4498567</ArticleId>
<ArticleId IdType="mid">NIHMS705642</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000842 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000842 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:24110644
   |texte=   Haptic perception of multi-joint hypertonia during simulated patient-therapist physical tele-interaction.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:24110644" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024