Using catheter needles to deliver an intraocular lens for intrascleral fixation.

Identifieur interne : 000765 ( PubMed/Corpus ); précédent : 000764; suivant : 000766

Using catheter needles to deliver an intraocular lens for intrascleral fixation.

Auteurs : Masayuki Akimoto ; Hogara Taguchi ; Toshihide Takahashi

Source :

RBID : pubmed:24461497

English descriptors

Abstract

A new method for delivering intraocular lens (IOL) haptics through sclerotomies for intrascleral fixation using catheter needles was evaluated in pig eyes. A bent catheter needle was used to penetrate the surgical corneal wound from the presumed sclerotomy. Extraocularly, the leading haptic of the IOL was fixated between the external tube and the internal needle of the catheter needle. The fixation was strong enough to support the IOL and to extract the leading haptic through the sclerotomy site. The trailing haptic was fixated using another catheter needle extraocularly and was subsequently delivered through another sclerotomy site. Guiding with a needle was the only intraocular manipulation when delivering the trailing haptic and catheter needle through the sclerotomy. This new method is easy and safe and does not require special devices compared with other methods. Clinical evaluation in human eyes should be performed.

DOI: 10.1016/j.jcrs.2013.12.009
PubMed: 24461497

Links to Exploration step

pubmed:24461497

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Using catheter needles to deliver an intraocular lens for intrascleral fixation.</title>
<author>
<name sortKey="Akimoto, Masayuki" sort="Akimoto, Masayuki" uniqKey="Akimoto M" first="Masayuki" last="Akimoto">Masayuki Akimoto</name>
<affiliation>
<nlm:affiliation>From the Department of Ophthalmology, Osaka Red Cross Hospital, Osaka, Japan. Electronic address: masayuki@akimoto3.com.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Taguchi, Hogara" sort="Taguchi, Hogara" uniqKey="Taguchi H" first="Hogara" last="Taguchi">Hogara Taguchi</name>
<affiliation>
<nlm:affiliation>From the Department of Ophthalmology, Osaka Red Cross Hospital, Osaka, Japan.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Takahashi, Toshihide" sort="Takahashi, Toshihide" uniqKey="Takahashi T" first="Toshihide" last="Takahashi">Toshihide Takahashi</name>
<affiliation>
<nlm:affiliation>From the Department of Ophthalmology, Osaka Red Cross Hospital, Osaka, Japan.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="doi">10.1016/j.jcrs.2013.12.009</idno>
<idno type="RBID">pubmed:24461497</idno>
<idno type="pmid">24461497</idno>
<idno type="wicri:Area/PubMed/Corpus">000765</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Using catheter needles to deliver an intraocular lens for intrascleral fixation.</title>
<author>
<name sortKey="Akimoto, Masayuki" sort="Akimoto, Masayuki" uniqKey="Akimoto M" first="Masayuki" last="Akimoto">Masayuki Akimoto</name>
<affiliation>
<nlm:affiliation>From the Department of Ophthalmology, Osaka Red Cross Hospital, Osaka, Japan. Electronic address: masayuki@akimoto3.com.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Taguchi, Hogara" sort="Taguchi, Hogara" uniqKey="Taguchi H" first="Hogara" last="Taguchi">Hogara Taguchi</name>
<affiliation>
<nlm:affiliation>From the Department of Ophthalmology, Osaka Red Cross Hospital, Osaka, Japan.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Takahashi, Toshihide" sort="Takahashi, Toshihide" uniqKey="Takahashi T" first="Toshihide" last="Takahashi">Toshihide Takahashi</name>
<affiliation>
<nlm:affiliation>From the Department of Ophthalmology, Osaka Red Cross Hospital, Osaka, Japan.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="eISSN">1873-4502</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Animals</term>
<term>Aphakia, Postcataract (surgery)</term>
<term>Catheterization (instrumentation)</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Models, Animal</term>
<term>Needles</term>
<term>Phacoemulsification</term>
<term>Sclera (surgery)</term>
<term>Sclerostomy</term>
<term>Swine</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Catheterization</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Aphakia, Postcataract</term>
<term>Sclera</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Animals</term>
<term>Lenses, Intraocular</term>
<term>Models, Animal</term>
<term>Needles</term>
<term>Phacoemulsification</term>
<term>Sclerostomy</term>
<term>Swine</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A new method for delivering intraocular lens (IOL) haptics through sclerotomies for intrascleral fixation using catheter needles was evaluated in pig eyes. A bent catheter needle was used to penetrate the surgical corneal wound from the presumed sclerotomy. Extraocularly, the leading haptic of the IOL was fixated between the external tube and the internal needle of the catheter needle. The fixation was strong enough to support the IOL and to extract the leading haptic through the sclerotomy site. The trailing haptic was fixated using another catheter needle extraocularly and was subsequently delivered through another sclerotomy site. Guiding with a needle was the only intraocular manipulation when delivering the trailing haptic and catheter needle through the sclerotomy. This new method is easy and safe and does not require special devices compared with other methods. Clinical evaluation in human eyes should be performed.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">24461497</PMID>
<DateCreated>
<Year>2014</Year>
<Month>01</Month>
<Day>27</Day>
</DateCreated>
<DateCompleted>
<Year>2014</Year>
<Month>08</Month>
<Day>06</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1873-4502</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>40</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2014</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Using catheter needles to deliver an intraocular lens for intrascleral fixation.</ArticleTitle>
<Pagination>
<MedlinePgn>179-83</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.jcrs.2013.12.009</ELocationID>
<ELocationID EIdType="pii" ValidYN="Y">S0886-3350(13)01623-4</ELocationID>
<Abstract>
<AbstractText Label="UNLABELLED">A new method for delivering intraocular lens (IOL) haptics through sclerotomies for intrascleral fixation using catheter needles was evaluated in pig eyes. A bent catheter needle was used to penetrate the surgical corneal wound from the presumed sclerotomy. Extraocularly, the leading haptic of the IOL was fixated between the external tube and the internal needle of the catheter needle. The fixation was strong enough to support the IOL and to extract the leading haptic through the sclerotomy site. The trailing haptic was fixated using another catheter needle extraocularly and was subsequently delivered through another sclerotomy site. Guiding with a needle was the only intraocular manipulation when delivering the trailing haptic and catheter needle through the sclerotomy. This new method is easy and safe and does not require special devices compared with other methods. Clinical evaluation in human eyes should be performed.</AbstractText>
<AbstractText Label="FINANCIAL DISCLOSURE" NlmCategory="BACKGROUND">Dr. Akimoto is a consultant to Kowa Co. Ltd. A patent application on the modified catheter needle is planned. No other author has a financial or proprietary interest in any material or method mentioned.</AbstractText>
<CopyrightInformation>Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Akimoto</LastName>
<ForeName>Masayuki</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>From the Department of Ophthalmology, Osaka Red Cross Hospital, Osaka, Japan. Electronic address: masayuki@akimoto3.com.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Taguchi</LastName>
<ForeName>Hogara</ForeName>
<Initials>H</Initials>
<AffiliationInfo>
<Affiliation>From the Department of Ophthalmology, Osaka Red Cross Hospital, Osaka, Japan.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Takahashi</LastName>
<ForeName>Toshihide</ForeName>
<Initials>T</Initials>
<AffiliationInfo>
<Affiliation>From the Department of Ophthalmology, Osaka Red Cross Hospital, Osaka, Japan.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<CommentsCorrectionsList>
<CommentsCorrections RefType="CommentIn">
<RefSource>J Cataract Refract Surg. 2014 May;40(5):853-4</RefSource>
<PMID Version="1">24767934</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="CommentIn">
<RefSource>J Cataract Refract Surg. 2014 May;40(5):854-5</RefSource>
<PMID Version="1">24767935</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000818">Animals</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001036">Aphakia, Postcataract</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002404">Catheterization</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D023421">Models, Animal</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D009339">Needles</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012590">Sclera</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012599">Sclerostomy</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013552">Swine</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2013</Year>
<Month>7</Month>
<Day>14</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised">
<Year>2013</Year>
<Month>9</Month>
<Day>20</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2013</Year>
<Month>10</Month>
<Day>3</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>1</Month>
<Day>28</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>1</Month>
<Day>28</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2014</Year>
<Month>8</Month>
<Day>7</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0886-3350(13)01623-4</ArticleId>
<ArticleId IdType="doi">10.1016/j.jcrs.2013.12.009</ArticleId>
<ArticleId IdType="pubmed">24461497</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000765 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000765 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:24461497
   |texte=   Using catheter needles to deliver an intraocular lens for intrascleral fixation.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:24461497" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024