Simplified insertion technique for the SI-26NB intraocular lens.

Identifieur interne : 001F10 ( PubMed/Checkpoint ); précédent : 001F09; suivant : 001F11

Simplified insertion technique for the SI-26NB intraocular lens.

Auteurs : K T Oh ; K T Oh

Source :

RBID : pubmed:1432678

English descriptors

Abstract

Inserting the 13 mm SI-26NB intraocular lens is a challenging task complicated by the need to tuck the modified C-configuration haptics within a folded optic. This step causes undue stress on the haptic and may result in asymmetrical distortion and subsequent decentration. Excluding this step simplifies the technique, as well as decreases the degree of acute angle stress on the haptic as it is passed through the scleral tunnel.

PubMed: 1432678


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:1432678

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Simplified insertion technique for the SI-26NB intraocular lens.</title>
<author>
<name sortKey="Oh, K T" sort="Oh, K T" uniqKey="Oh K" first="K T" last="Oh">K T Oh</name>
</author>
<author>
<name sortKey="Oh, K T" sort="Oh, K T" uniqKey="Oh K" first="K T" last="Oh">K T Oh</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1992">1992</date>
<idno type="RBID">pubmed:1432678</idno>
<idno type="pmid">1432678</idno>
<idno type="wicri:Area/PubMed/Corpus">002185</idno>
<idno type="wicri:Area/PubMed/Curation">002185</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001F10</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Simplified insertion technique for the SI-26NB intraocular lens.</title>
<author>
<name sortKey="Oh, K T" sort="Oh, K T" uniqKey="Oh K" first="K T" last="Oh">K T Oh</name>
</author>
<author>
<name sortKey="Oh, K T" sort="Oh, K T" uniqKey="Oh K" first="K T" last="Oh">K T Oh</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="1992" type="published">1992</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Cataract Extraction (methods)</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Polypropylenes</term>
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Polypropylenes</term>
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Cataract Extraction</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Inserting the 13 mm SI-26NB intraocular lens is a challenging task complicated by the need to tuck the modified C-configuration haptics within a folded optic. This step causes undue stress on the haptic and may result in asymmetrical distortion and subsequent decentration. Excluding this step simplifies the technique, as well as decreases the degree of acute angle stress on the haptic as it is passed through the scleral tunnel.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">1432678</PMID>
<DateCreated>
<Year>1992</Year>
<Month>12</Month>
<Day>16</Day>
</DateCreated>
<DateCompleted>
<Year>1992</Year>
<Month>12</Month>
<Day>16</Day>
</DateCompleted>
<DateRevised>
<Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>18</Volume>
<Issue>6</Issue>
<PubDate>
<Year>1992</Year>
<Month>Nov</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Simplified insertion technique for the SI-26NB intraocular lens.</ArticleTitle>
<Pagination>
<MedlinePgn>619-22</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Inserting the 13 mm SI-26NB intraocular lens is a challenging task complicated by the need to tuck the modified C-configuration haptics within a folded optic. This step causes undue stress on the haptic and may result in asymmetrical distortion and subsequent decentration. Excluding this step simplifies the technique, as well as decreases the degree of acute angle stress on the haptic as it is passed through the scleral tunnel.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Oh</LastName>
<ForeName>K T</ForeName>
<Initials>KT</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Oh</LastName>
<ForeName>K T</ForeName>
<Initials>KT</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011126">Polypropylenes</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012826">Silicone Elastomers</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002387">Cataract Extraction</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011126">Polypropylenes</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012826">Silicone Elastomers</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1992</Year>
<Month>11</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1992</Year>
<Month>11</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1992</Year>
<Month>11</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">1432678</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Oh, K T" sort="Oh, K T" uniqKey="Oh K" first="K T" last="Oh">K T Oh</name>
<name sortKey="Oh, K T" sort="Oh, K T" uniqKey="Oh K" first="K T" last="Oh">K T Oh</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001F10 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 001F10 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:1432678
   |texte=   Simplified insertion technique for the SI-26NB intraocular lens.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:1432678" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024