Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses.

Identifieur interne : 001E83 ( PubMed/Checkpoint ); précédent : 001E82; suivant : 001E84

Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses.

Auteurs : J S Cumming [États-Unis]

Source :

RBID : pubmed:8487172

English descriptors

Abstract

Complications after implantation of 503 plate haptic silicone intraocular lenses were compared with those after implantation of 253 silicone three-piece polypropylene loop lenses. The uncorrected visual acuities were also compared. Capsulorhexis and endocapsular phacoemulsification were used in all cases. The incidence of cystoid macular edema and posterior capsule opacification requiring a YAG capsulotomy were significantly higher in the cases with polypropylene three-piece loop lenses. Pigment dispersion and decentration also occurred more frequently in this group. This is probably because the 10.5 mm plate haptic lens is more rigid than the polypropylene loop lens. It also fixates more posteriorly within the capsular bag than the anteriorly located polypropylene lens. Patients implanted with a plate haptic silicone intraocular lens through a 3.5 mm scleral incision had significantly better uncorrected visual acuity at five to six weeks postoperatively than those with a three-piece silicone lens that required a 4.5 mm incision for insertion.

PubMed: 8487172


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:8487172

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses.</title>
<author>
<name sortKey="Cumming, J S" sort="Cumming, J S" uniqKey="Cumming J" first="J S" last="Cumming">J S Cumming</name>
<affiliation wicri:level="2">
<nlm:affiliation>Anaheim Eye Medical Group, Inc., California 92801.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName>
<region type="state">Californie</region>
</placeName>
<wicri:cityArea>Anaheim Eye Medical Group, Inc.</wicri:cityArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1993">1993</date>
<idno type="RBID">pubmed:8487172</idno>
<idno type="pmid">8487172</idno>
<idno type="wicri:Area/PubMed/Corpus">002167</idno>
<idno type="wicri:Area/PubMed/Curation">002167</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001E83</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses.</title>
<author>
<name sortKey="Cumming, J S" sort="Cumming, J S" uniqKey="Cumming J" first="J S" last="Cumming">J S Cumming</name>
<affiliation wicri:level="2">
<nlm:affiliation>Anaheim Eye Medical Group, Inc., California 92801.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName>
<region type="state">Californie</region>
</placeName>
<wicri:cityArea>Anaheim Eye Medical Group, Inc.</wicri:cityArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="1993" type="published">1993</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Cataract Extraction</term>
<term>Female</term>
<term>Humans</term>
<term>Incidence</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Polypropylenes</term>
<term>Postoperative Complications (etiology)</term>
<term>Prosthesis Design</term>
<term>Silicone Elastomers</term>
<term>Vision Disorders (etiology)</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Polypropylenes</term>
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Postoperative Complications</term>
<term>Vision Disorders</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Cataract Extraction</term>
<term>Female</term>
<term>Humans</term>
<term>Incidence</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Prosthesis Design</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Complications after implantation of 503 plate haptic silicone intraocular lenses were compared with those after implantation of 253 silicone three-piece polypropylene loop lenses. The uncorrected visual acuities were also compared. Capsulorhexis and endocapsular phacoemulsification were used in all cases. The incidence of cystoid macular edema and posterior capsule opacification requiring a YAG capsulotomy were significantly higher in the cases with polypropylene three-piece loop lenses. Pigment dispersion and decentration also occurred more frequently in this group. This is probably because the 10.5 mm plate haptic lens is more rigid than the polypropylene loop lens. It also fixates more posteriorly within the capsular bag than the anteriorly located polypropylene lens. Patients implanted with a plate haptic silicone intraocular lens through a 3.5 mm scleral incision had significantly better uncorrected visual acuity at five to six weeks postoperatively than those with a three-piece silicone lens that required a 4.5 mm incision for insertion.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">8487172</PMID>
<DateCreated>
<Year>1993</Year>
<Month>06</Month>
<Day>07</Day>
</DateCreated>
<DateCompleted>
<Year>1993</Year>
<Month>06</Month>
<Day>07</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>19</Volume>
<Issue>2</Issue>
<PubDate>
<Year>1993</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses.</ArticleTitle>
<Pagination>
<MedlinePgn>263-74</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Complications after implantation of 503 plate haptic silicone intraocular lenses were compared with those after implantation of 253 silicone three-piece polypropylene loop lenses. The uncorrected visual acuities were also compared. Capsulorhexis and endocapsular phacoemulsification were used in all cases. The incidence of cystoid macular edema and posterior capsule opacification requiring a YAG capsulotomy were significantly higher in the cases with polypropylene three-piece loop lenses. Pigment dispersion and decentration also occurred more frequently in this group. This is probably because the 10.5 mm plate haptic lens is more rigid than the polypropylene loop lens. It also fixates more posteriorly within the capsular bag than the anteriorly located polypropylene lens. Patients implanted with a plate haptic silicone intraocular lens through a 3.5 mm scleral incision had significantly better uncorrected visual acuity at five to six weeks postoperatively than those with a three-piece silicone lens that required a 4.5 mm incision for insertion.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Cumming</LastName>
<ForeName>J S</ForeName>
<Initials>JS</Initials>
<AffiliationInfo>
<Affiliation>Anaheim Eye Medical Group, Inc., California 92801.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011126">Polypropylenes</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012826">Silicone Elastomers</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002387">Cataract Extraction</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D015994">Incidence</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007910">Lenses, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000009">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011126">Polypropylenes</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011183">Postoperative Complications</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D012826">Silicone Elastomers</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014786">Vision Disorders</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1993</Year>
<Month>3</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1993</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1993</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">8487172</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
<region>
<li>Californie</li>
</region>
</list>
<tree>
<country name="États-Unis">
<region name="Californie">
<name sortKey="Cumming, J S" sort="Cumming, J S" uniqKey="Cumming J" first="J S" last="Cumming">J S Cumming</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001E83 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 001E83 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:8487172
   |texte=   Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:8487172" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024