Real-time visually and haptically accurate surgical simulation.
Identifieur interne : 001D94 ( PubMed/Checkpoint ); précédent : 001D93; suivant : 001D95Real-time visually and haptically accurate surgical simulation.
Auteurs : K D Reinig [États-Unis] ; C G Rush ; H L Pelster ; V M Spitzer ; J A HeathSource :
- Studies in health technology and informatics [ 0926-9630 ] ; 1996.
English descriptors
- KwdEn :
- MESH :
Abstract
The Visible Human Database provides a complete submillimeter photographic and radiological description of both a male and a female cadaver. The Center for Human Simulation has developed real-time algorithms that allow a user to wield a virtual scalpel and produce arbitrary cuts into the reconstructed body. Real-time interaction is achieved by producing the appropriate texture mapped surfaces directly from the Visible Human Database. We are currently combining a 3 degree of freedom PHANToM haptic device (SensAble Devices) with our surgical cutting algorithms to produce a system with the look and feel of surgical cutting.
PubMed: 10163781
Affiliations:
Links toward previous steps (curation, corpus...)
Links to Exploration step
pubmed:10163781Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Real-time visually and haptically accurate surgical simulation.</title>
<author><name sortKey="Reinig, K D" sort="Reinig, K D" uniqKey="Reinig K" first="K D" last="Reinig">K D Reinig</name>
<affiliation wicri:level="1"><nlm:affiliation>Center for Human Simulation, University of Colorado Health Sciences Center, Denver 80262, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Center for Human Simulation, University of Colorado Health Sciences Center, Denver 80262</wicri:regionArea>
<wicri:noRegion>Denver 80262</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Rush, C G" sort="Rush, C G" uniqKey="Rush C" first="C G" last="Rush">C G Rush</name>
</author>
<author><name sortKey="Pelster, H L" sort="Pelster, H L" uniqKey="Pelster H" first="H L" last="Pelster">H L Pelster</name>
</author>
<author><name sortKey="Spitzer, V M" sort="Spitzer, V M" uniqKey="Spitzer V" first="V M" last="Spitzer">V M Spitzer</name>
</author>
<author><name sortKey="Heath, J A" sort="Heath, J A" uniqKey="Heath J" first="J A" last="Heath">J A Heath</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1996">1996</date>
<idno type="RBID">pubmed:10163781</idno>
<idno type="pmid">10163781</idno>
<idno type="wicri:Area/PubMed/Corpus">002090</idno>
<idno type="wicri:Area/PubMed/Curation">002090</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001D94</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Real-time visually and haptically accurate surgical simulation.</title>
<author><name sortKey="Reinig, K D" sort="Reinig, K D" uniqKey="Reinig K" first="K D" last="Reinig">K D Reinig</name>
<affiliation wicri:level="1"><nlm:affiliation>Center for Human Simulation, University of Colorado Health Sciences Center, Denver 80262, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Center for Human Simulation, University of Colorado Health Sciences Center, Denver 80262</wicri:regionArea>
<wicri:noRegion>Denver 80262</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Rush, C G" sort="Rush, C G" uniqKey="Rush C" first="C G" last="Rush">C G Rush</name>
</author>
<author><name sortKey="Pelster, H L" sort="Pelster, H L" uniqKey="Pelster H" first="H L" last="Pelster">H L Pelster</name>
</author>
<author><name sortKey="Spitzer, V M" sort="Spitzer, V M" uniqKey="Spitzer V" first="V M" last="Spitzer">V M Spitzer</name>
</author>
<author><name sortKey="Heath, J A" sort="Heath, J A" uniqKey="Heath J" first="J A" last="Heath">J A Heath</name>
</author>
</analytic>
<series><title level="j">Studies in health technology and informatics</title>
<idno type="ISSN">0926-9630</idno>
<imprint><date when="1996" type="published">1996</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Anatomy, Cross-Sectional</term>
<term>Computer Simulation</term>
<term>Female</term>
<term>General Surgery</term>
<term>Humans</term>
<term>Information Systems</term>
<term>Male</term>
<term>Touch</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Anatomy, Cross-Sectional</term>
<term>Computer Simulation</term>
<term>Female</term>
<term>General Surgery</term>
<term>Humans</term>
<term>Information Systems</term>
<term>Male</term>
<term>Touch</term>
<term>User-Computer Interface</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The Visible Human Database provides a complete submillimeter photographic and radiological description of both a male and a female cadaver. The Center for Human Simulation has developed real-time algorithms that allow a user to wield a virtual scalpel and produce arbitrary cuts into the reconstructed body. Real-time interaction is achieved by producing the appropriate texture mapped surfaces directly from the Visible Human Database. We are currently combining a 3 degree of freedom PHANToM haptic device (SensAble Devices) with our surgical cutting algorithms to produce a system with the look and feel of surgical cutting.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">10163781</PMID>
<DateCreated><Year>1997</Year>
<Month>01</Month>
<Day>30</Day>
</DateCreated>
<DateCompleted><Year>1997</Year>
<Month>01</Month>
<Day>30</Day>
</DateCompleted>
<DateRevised><Year>2008</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0926-9630</ISSN>
<JournalIssue CitedMedium="Print"><Volume>29</Volume>
<PubDate><Year>1996</Year>
</PubDate>
</JournalIssue>
<Title>Studies in health technology and informatics</Title>
<ISOAbbreviation>Stud Health Technol Inform</ISOAbbreviation>
</Journal>
<ArticleTitle>Real-time visually and haptically accurate surgical simulation.</ArticleTitle>
<Pagination><MedlinePgn>542-5</MedlinePgn>
</Pagination>
<Abstract><AbstractText>The Visible Human Database provides a complete submillimeter photographic and radiological description of both a male and a female cadaver. The Center for Human Simulation has developed real-time algorithms that allow a user to wield a virtual scalpel and produce arbitrary cuts into the reconstructed body. Real-time interaction is achieved by producing the appropriate texture mapped surfaces directly from the Visible Human Database. We are currently combining a 3 degree of freedom PHANToM haptic device (SensAble Devices) with our surgical cutting algorithms to produce a system with the look and feel of surgical cutting.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Reinig</LastName>
<ForeName>K D</ForeName>
<Initials>KD</Initials>
<AffiliationInfo><Affiliation>Center for Human Simulation, University of Colorado Health Sciences Center, Denver 80262, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Rush</LastName>
<ForeName>C G</ForeName>
<Initials>CG</Initials>
</Author>
<Author ValidYN="Y"><LastName>Pelster</LastName>
<ForeName>H L</ForeName>
<Initials>HL</Initials>
</Author>
<Author ValidYN="Y"><LastName>Spitzer</LastName>
<ForeName>V M</ForeName>
<Initials>VM</Initials>
</Author>
<Author ValidYN="Y"><LastName>Heath</LastName>
<ForeName>J A</ForeName>
<Initials>JA</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>NETHERLANDS</Country>
<MedlineTA>Stud Health Technol Inform</MedlineTA>
<NlmUniqueID>9214582</NlmUniqueID>
<ISSNLinking>0926-9630</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>T</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="Y" UI="D019412">Anatomy, Cross-Sectional</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D003198">Computer Simulation</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D013502">General Surgery</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007256">Information Systems</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D014110">Touch</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D014584">User-Computer Interface</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>1995</Year>
<Month>12</Month>
<Day>9</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>1995</Year>
<Month>12</Month>
<Day>9</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>1995</Year>
<Month>12</Month>
<Day>9</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">10163781</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations><list><country><li>États-Unis</li>
</country>
</list>
<tree><noCountry><name sortKey="Heath, J A" sort="Heath, J A" uniqKey="Heath J" first="J A" last="Heath">J A Heath</name>
<name sortKey="Pelster, H L" sort="Pelster, H L" uniqKey="Pelster H" first="H L" last="Pelster">H L Pelster</name>
<name sortKey="Rush, C G" sort="Rush, C G" uniqKey="Rush C" first="C G" last="Rush">C G Rush</name>
<name sortKey="Spitzer, V M" sort="Spitzer, V M" uniqKey="Spitzer V" first="V M" last="Spitzer">V M Spitzer</name>
</noCountry>
<country name="États-Unis"><noRegion><name sortKey="Reinig, K D" sort="Reinig, K D" uniqKey="Reinig K" first="K D" last="Reinig">K D Reinig</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001D94 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 001D94 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Checkpoint |type= RBID |clé= pubmed:10163781 |texte= Real-time visually and haptically accurate surgical simulation. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i -Sk "pubmed:10163781" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |