Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback.
Identifieur interne : 001487 ( PubMed/Checkpoint ); précédent : 001486; suivant : 001488Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback.
Auteurs : P Pat Banerjee [États-Unis] ; Cristian J. Luciano ; G Michael Lemole ; Fady T. Charbel ; Michael Y. OhSource :
- Journal of neurosurgery [ 0022-3085 ] ; 2007.
English descriptors
- KwdEn :
- MESH :
- education : Neuronavigation, Ventriculostomy.
- instrumentation : Computer-Assisted Instruction.
- Catheterization, Clinical Competence, Computer Simulation, Feedback, Humans, Internship and Residency, Reproducibility of Results, User-Computer Interface.
Abstract
The purpose of this study was to evaluate the accuracy of ventriculostomy catheter placement on a head- and hand-tracked high-resolution and high-performance virtual reality and haptic technology workstation.
DOI: 10.3171/JNS-07/09/0515
PubMed: 17886549
Affiliations:
Links toward previous steps (curation, corpus...)
Links to Exploration step
pubmed:17886549Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback.</title>
<author><name sortKey="Banerjee, P Pat" sort="Banerjee, P Pat" uniqKey="Banerjee P" first="P Pat" last="Banerjee">P Pat Banerjee</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago 60607, USA. banerjee@uic.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago 60607</wicri:regionArea>
<wicri:noRegion>University of Illinois at Chicago 60607</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Luciano, Cristian J" sort="Luciano, Cristian J" uniqKey="Luciano C" first="Cristian J" last="Luciano">Cristian J. Luciano</name>
</author>
<author><name sortKey="Lemole, G Michael" sort="Lemole, G Michael" uniqKey="Lemole G" first="G Michael" last="Lemole">G Michael Lemole</name>
</author>
<author><name sortKey="Charbel, Fady T" sort="Charbel, Fady T" uniqKey="Charbel F" first="Fady T" last="Charbel">Fady T. Charbel</name>
</author>
<author><name sortKey="Oh, Michael Y" sort="Oh, Michael Y" uniqKey="Oh M" first="Michael Y" last="Oh">Michael Y. Oh</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2007">2007</date>
<idno type="RBID">pubmed:17886549</idno>
<idno type="pmid">17886549</idno>
<idno type="doi">10.3171/JNS-07/09/0515</idno>
<idno type="wicri:Area/PubMed/Corpus">001582</idno>
<idno type="wicri:Area/PubMed/Curation">001582</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001487</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback.</title>
<author><name sortKey="Banerjee, P Pat" sort="Banerjee, P Pat" uniqKey="Banerjee P" first="P Pat" last="Banerjee">P Pat Banerjee</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago 60607, USA. banerjee@uic.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago 60607</wicri:regionArea>
<wicri:noRegion>University of Illinois at Chicago 60607</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Luciano, Cristian J" sort="Luciano, Cristian J" uniqKey="Luciano C" first="Cristian J" last="Luciano">Cristian J. Luciano</name>
</author>
<author><name sortKey="Lemole, G Michael" sort="Lemole, G Michael" uniqKey="Lemole G" first="G Michael" last="Lemole">G Michael Lemole</name>
</author>
<author><name sortKey="Charbel, Fady T" sort="Charbel, Fady T" uniqKey="Charbel F" first="Fady T" last="Charbel">Fady T. Charbel</name>
</author>
<author><name sortKey="Oh, Michael Y" sort="Oh, Michael Y" uniqKey="Oh M" first="Michael Y" last="Oh">Michael Y. Oh</name>
</author>
</analytic>
<series><title level="j">Journal of neurosurgery</title>
<idno type="ISSN">0022-3085</idno>
<imprint><date when="2007" type="published">2007</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Catheterization</term>
<term>Clinical Competence</term>
<term>Computer Simulation</term>
<term>Computer-Assisted Instruction (instrumentation)</term>
<term>Feedback</term>
<term>Humans</term>
<term>Internship and Residency</term>
<term>Neuronavigation (education)</term>
<term>Reproducibility of Results</term>
<term>User-Computer Interface</term>
<term>Ventriculostomy (education)</term>
</keywords>
<keywords scheme="MESH" qualifier="education" xml:lang="en"><term>Neuronavigation</term>
<term>Ventriculostomy</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Computer-Assisted Instruction</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Catheterization</term>
<term>Clinical Competence</term>
<term>Computer Simulation</term>
<term>Feedback</term>
<term>Humans</term>
<term>Internship and Residency</term>
<term>Reproducibility of Results</term>
<term>User-Computer Interface</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The purpose of this study was to evaluate the accuracy of ventriculostomy catheter placement on a head- and hand-tracked high-resolution and high-performance virtual reality and haptic technology workstation.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">17886549</PMID>
<DateCreated><Year>2007</Year>
<Month>09</Month>
<Day>24</Day>
</DateCreated>
<DateCompleted><Year>2007</Year>
<Month>10</Month>
<Day>11</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0022-3085</ISSN>
<JournalIssue CitedMedium="Print"><Volume>107</Volume>
<Issue>3</Issue>
<PubDate><Year>2007</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Journal of neurosurgery</Title>
<ISOAbbreviation>J. Neurosurg.</ISOAbbreviation>
</Journal>
<ArticleTitle>Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback.</ArticleTitle>
<Pagination><MedlinePgn>515-21</MedlinePgn>
</Pagination>
<Abstract><AbstractText Label="OBJECT" NlmCategory="OBJECTIVE">The purpose of this study was to evaluate the accuracy of ventriculostomy catheter placement on a head- and hand-tracked high-resolution and high-performance virtual reality and haptic technology workstation.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Seventy-eight fellows and residents performed simulated ventriculostomy catheter placement on an ImmersiveTouch system. The virtual catheter was placed into a virtual patient's head derived from a computed tomography data set. Participants were allowed one attempt each. The distance from the tip of the catheter to the Monro foramen was measured.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The mean distance (+/- standard deviation) from the final position of the catheter tip to the Monro foramen was 16.09 mm (+/- 7.85 mm).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">The accuracy of virtual ventriculostomy catheter placement achieved by participants using the simulator is comparable to the accuracy reported in a recent retrospective evaluation of free-hand ventriculostomy placements in which the mean distance from the catheter tip to the Monro foramen was 16 mm (+/- 9.6 mm).</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Banerjee</LastName>
<ForeName>P Pat</ForeName>
<Initials>PP</Initials>
<AffiliationInfo><Affiliation>Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago 60607, USA. banerjee@uic.edu</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Luciano</LastName>
<ForeName>Cristian J</ForeName>
<Initials>CJ</Initials>
</Author>
<Author ValidYN="Y"><LastName>Lemole</LastName>
<ForeName>G Michael</ForeName>
<Initials>GM</Initials>
<Suffix>Jr</Suffix>
</Author>
<Author ValidYN="Y"><LastName>Charbel</LastName>
<ForeName>Fady T</ForeName>
<Initials>FT</Initials>
</Author>
<Author ValidYN="Y"><LastName>Oh</LastName>
<ForeName>Michael Y</ForeName>
<Initials>MY</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D023362">Evaluation Studies</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
<PublicationType UI="D013486">Research Support, U.S. Gov't, Non-P.H.S.</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>J Neurosurg</MedlineTA>
<NlmUniqueID>0253357</NlmUniqueID>
<ISSNLinking>0022-3085</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>AIM</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="Y" UI="D002404">Catheterization</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D002983">Clinical Competence</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D003198">Computer Simulation</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D003194">Computer-Assisted Instruction</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005246">Feedback</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007396">Internship and Residency</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D038361">Neuronavigation</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000193">education</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D015203">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D014584">User-Computer Interface</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014696">Ventriculostomy</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000193">education</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>2007</Year>
<Month>9</Month>
<Day>25</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2007</Year>
<Month>10</Month>
<Day>12</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2007</Year>
<Month>9</Month>
<Day>25</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">17886549</ArticleId>
<ArticleId IdType="doi">10.3171/JNS-07/09/0515</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations><list><country><li>États-Unis</li>
</country>
</list>
<tree><noCountry><name sortKey="Charbel, Fady T" sort="Charbel, Fady T" uniqKey="Charbel F" first="Fady T" last="Charbel">Fady T. Charbel</name>
<name sortKey="Lemole, G Michael" sort="Lemole, G Michael" uniqKey="Lemole G" first="G Michael" last="Lemole">G Michael Lemole</name>
<name sortKey="Luciano, Cristian J" sort="Luciano, Cristian J" uniqKey="Luciano C" first="Cristian J" last="Luciano">Cristian J. Luciano</name>
<name sortKey="Oh, Michael Y" sort="Oh, Michael Y" uniqKey="Oh M" first="Michael Y" last="Oh">Michael Y. Oh</name>
</noCountry>
<country name="États-Unis"><noRegion><name sortKey="Banerjee, P Pat" sort="Banerjee, P Pat" uniqKey="Banerjee P" first="P Pat" last="Banerjee">P Pat Banerjee</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001487 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 001487 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Checkpoint |type= RBID |clé= pubmed:17886549 |texte= Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i -Sk "pubmed:17886549" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |