Orthognathic model surgery by using of a passive Robot Arm

Identifieur interne : 002620 ( Pmc/Corpus ); précédent : 002619; suivant : 002621

Orthognathic model surgery by using of a passive Robot Arm

Auteurs : Esam Ahmad Z. Omar ; M. A. Bamber

Source :

RBID : PMC:3824638

Abstract

Purpose

The possibility of using a passive Robot Arm (3D method) in model surgery and comparing with manual technique model surgery.

Patients and methods

Seventeen patients undergoing orthognathic surgery gave consent for this study. Model surgery was performed by using a manual technique and using the Robot Arm. The model surgery that was performed by using the manual technique named group A and the one performed by the Robot Arm named group B. Patients’ maxillary casts were measured before and after model surgery, and results were compared with those for the original treatment plan in the horizontal (X-axis), vertical (Y-axis), and transverse (Z-axis) planes.

Results

Statistical analysis using Mann–Whitney U test for X- and Y-axis and independent sample t test for Z-axis have shown significant differences between both groups in X-axis (P = .026) and Y-axis (P = .021) but not in Z-axis (P = .762).

Conclusions

Model surgery performed with a Robot Arm is more accurate in all dimensions X, Y, and Z than the manual model surgery.


Url:
DOI: 10.1016/j.sdentj.2010.02.006
PubMed: 24227912
PubMed Central: 3824638

Links to Exploration step

PMC:3824638***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002620 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 002620 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:3824638
   |texte=   Orthognathic model surgery by using of a passive Robot Arm
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:24227912" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024