Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Traumatic Dislocation of Implanted Collamer Phakic Lens: A Case Report and Review of the Literature

Identifieur interne : 002149 ( Pmc/Corpus ); précédent : 002148; suivant : 002150

Traumatic Dislocation of Implanted Collamer Phakic Lens: A Case Report and Review of the Literature

Auteurs : Majid Moshirfar ; Brian C. Stagg ; Valliammai Muthappan ; Shail A. Vasavada

Source :

RBID : PMC:4066362

Abstract

Purpose :

Present a case of dislocation of an Implantable Collamer Lens (ICL) that occurs after blunt trauma and review the published literature on this topic.

Methods :

Case report and literature review using PubMed.

Results :

A 44 year-old male presented to the emergency department with sudden onset of blurry vision after blunt trauma to the left eye. Three years prior, he had undergone bilateral ICL placement for high myopia. On examination, the superotemporal haptic was noted to be dislocated into the anterior chamber, but there was no endothelial touch by the dislocated lens. The patient had an associated hyphema that was medically managed, and 2 weeks after the injury, the patient underwent ICL repositioning. A review of the literature was performed and five previous cases of ICL dislocation were identified. Three of these occurred after blunt trauma. One of these cases was associated with endothelial touch and decompensation and eventually required a descement’s stripping endothelial keratoplasty (DSAEK).

Conclusion :

Dislocation of ICLs after blunt trauma is a rare but important potential sequela of the procedure and can lead to corneal decompensation if there is lens-endothelial touch. All patients who suffer blunt dislocation of ICL should be followed long-term after repositioning for signs of endothelial loss and dysfunction.


Url:
DOI: 10.2174/1874364101408010024
PubMed: 24959305
PubMed Central: 4066362

Links to Exploration step

PMC:4066362***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002149 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 002149 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4066362
   |texte=   Traumatic Dislocation of Implanted Collamer Phakic Lens: A Case Report and Review of the Literature
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:24959305" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024