Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Modeling and In Vitro Experimental Validation for Kinetics of the Colonoscope in Colonoscopy

Identifieur interne : 001639 ( Pmc/Corpus ); précédent : 001638; suivant : 001640

Modeling and In Vitro Experimental Validation for Kinetics of the Colonoscope in Colonoscopy

Auteurs : Wu-Bin Cheng ; Yun-Yun Di ; Edwin M. Zhang ; Michael A. J. Moser ; Sivaruban Kanagaratnam ; Louis Y. Korman ; Noune Sarvazyan ; Wen-Jun Zhang

Source :

RBID : PMC:3625492

Abstract

Colonoscopy is the most sensitive and specific means for detection of colon cancers and polyps. To make colonoscopy more effective several problems must be overcome including: pain associated with the procedure, the risk of perforation, and incomplete intubation colonoscopy. Technically, these problems are the result of loop formation during colonoscopy. Although, several solutions such as modifying the stiffness of the colonoscope, using an overtube and developing image-guided instruments have been introduced to resolve the looping problem, the results of these systems are not completely satisfactory. A new paradigm to overcome loop formation is proposed that is doctor-assistive colonoscopy. In this approach, the endoscopists performance is enhanced by providing using a kinetic model that provides information such as the shape of the scope, direction of the colon and forces exerted within certain sections. It is expected that with the help of this model, the endoscopist would be able to adjust the manipulation to avoid loop formation. In the present studies, the kinetic model is developed and validated using an ex vivo colonoscopy test-bed with a comprehensive kinematic and kinetic data collection. The model utilizes an established colon model based on animal tissue with position tracking sensors, contact force sensors for the intraluminal portion of the scope and a Colonoscopy Force Monitor for the external insertion tube.


Url:
DOI: 10.1007/s10439-013-0746-1
PubMed: 23358801
PubMed Central: 3625492

Links to Exploration step

PMC:3625492***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001639 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 001639 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:3625492
   |texte=   Modeling and In Vitro Experimental Validation for Kinetics of the Colonoscope in Colonoscopy
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:23358801" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024