Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Evaluation of Optimized Digital Fundus Reflex Photographs for Lens Opacities in the Age-Related Eye Disease Study 2: AREDS2 Report 7

Identifieur interne : 001367 ( Pmc/Corpus ); précédent : 001366; suivant : 001368

Evaluation of Optimized Digital Fundus Reflex Photographs for Lens Opacities in the Age-Related Eye Disease Study 2: AREDS2 Report 7

Auteurs : Amitha Domalpally ; Ronald P. Danis ; Emily Y. Chew ; Traci E. Clemons ; Susan Reed ; John Paul Sangiovanni ; Frederick L. Ferris

Source :

RBID : PMC:3771555

Abstract

Purpose.

We described the system for grading lens opacities using stereoscopic digital fundus reflex photographs in the Age-Related Eye Disease Study 2 (AREDS2) and compared reproducibility with the AREDS lens grading system, which used retroillumination film images.

Methods.

Stereoscopic fundus reflex photographs were acquired in a standardized fashion at baseline and annually. Images were enhanced and evaluated in the red channel at a central reading center. Percentage involvement of cortical and posterior subcapsular (PSC) lens opacities within the central 5 mm diameter zone of a modified AREDS lens grid was estimated. Reproducibility was assessed for contemporaneous variability (ongoing, monthly regrade on 5% of submissions, n = 777 eyes) and temporal drift (regrading a subset of baseline photographs annually, n = 88).

Results.

In the contemporaneous exercise, the agreement for presence of cortical opacities was 93% (κ = 0.86) and for PSC opacities it was 97% (κ = 0.83). Intraclass correlation (ICC) for area of central zone involvement was 0.95 for cortical and 0.99 for PSC opacities. Historic data for contemporaneous regrading of film-based images in AREDS showed an ICC of 0.94 for cortical and 0.82 for PSC. The final annual temporal drift exercise had a reproducibility of 95% for cortical and PSC opacities.

Conclusions.

Digital grading using fundus reflex images with image enhancing tools has reproducibility comparable to film-based retroillumination images, and may be useful for centralized objective lens opacity assessment in clinical trials using widely available fundus cameras. Red reflex images limit evaluation to cortical and PSC opacities, and do not permit assessment of nuclear opacities. (ClinicalTrials.gov number, NCT00345176.)


Url:
DOI: 10.1167/iovs.13-12301
PubMed: 23887802
PubMed Central: 3771555

Links to Exploration step

PMC:3771555***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001367 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 001367 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:3771555
   |texte=   Evaluation of Optimized Digital Fundus Reflex Photographs for Lens Opacities in the Age-Related Eye Disease Study 2: AREDS2 Report 7
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:23887802" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024