Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery

Identifieur interne : 000813 ( Pmc/Corpus ); précédent : 000812; suivant : 000814

A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery

Auteurs : Ken Hayashi ; Soichiro Ogawa ; Shin-Ichi Manabe ; Akira Hirata ; Koichi Yoshimura

Source :

RBID : PMC:4769725

Abstract

Purpose

The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery.

Methods

The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange.

Results

Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p < 0.0001). Major complications included a marked elevation in intraocular pressure (7.8 %), pupillary capture (6.5 %), and vitreous hemorrhage (2.6 %).

Conclusions

Based on the classification system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.


Url:
DOI: 10.1007/s00417-016-3273-6
PubMed: 26816295
PubMed Central: 4769725

Links to Exploration step

PMC:4769725***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000813 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000813 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4769725
   |texte=   A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:26816295" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024