Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Ureteroscopy and cystoscopy training: comparison between transparent and non-transparent simulators

Identifieur interne : 000747 ( Pmc/Corpus ); précédent : 000746; suivant : 000748

Ureteroscopy and cystoscopy training: comparison between transparent and non-transparent simulators

Auteurs : Wen-Gang Hu ; Jia-Yu Feng ; Jin Wang ; Ya-Jun Song ; Xiao-Ting Xu ; Hong Zhou ; Chi-Bing Huang

Source :

RBID : PMC:4457046

Abstract

Background

Simulators have been widely used to train operational skills in urology, how to improve its effectiveness deserves further investigation. In this paper, we evaluated training using a novel transparent anatomic simulator, an opaque model or no simulator training, with regard to post-training ureteroscopy and cystoscopy proficiency.

Methods

Anatomically correct transparent and non-transparent endourological simulators were fabricated. Ten experienced urologists provided a preliminary evaluation of the models as teaching tools. 36 first-year medical students underwent identical theoretical training and a 50-point examination of theoretical knowledge. The students were randomly assigned to receive training with the transparent simulator (Group 1), the non-transparent simulator (Group 2) or detailed verbal instruction only (Group 3). 12 days after the training session, the trainees’ skills at ureteral stent insertion and removal were evaluated using the Uro-Scopic Trainer and rated on an Objective Structured Assessment of Technical Skills (OSATS) scale.

Results

The new simulators were successfully fabricated in accordance with the design parameters. Of the ten urologists invited to evaluate the devices, 100 % rated the devices as anatomically accurate, 90 % thought both models were easy to use and 80 % thought they were good ureteroscopy and cystoscopy training tools. The scores on the theoretical knowledge test were comparable among the training groups, and all students were able to perform ureteral stent insertion and removal. The mean OSATS scores of groups 1, 2 and 3 were21.83 ± 3.64, 18.50 ± 4.03 and 15.58 ± 2.23 points, respectively, (p = 0.001).

Conclusions

Simulator training allowed students to achieve higher ureteroscopic and cystoscopic proficiency, and transparent simulators were more effective than non-transparent simulators.


Url:
DOI: 10.1186/s12909-015-0380-8
PubMed: 26032174
PubMed Central: 4457046

Links to Exploration step

PMC:4457046***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000747 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000747 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4457046
   |texte=   Ureteroscopy and cystoscopy training: comparison between transparent and non-transparent simulators
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:26032174" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024