Robotic Arm-assisted UKA Improves Tibial Component Alignment: A Pilot Study

Identifieur interne : 000702 ( Pmc/Corpus ); précédent : 000701; suivant : 000703

Robotic Arm-assisted UKA Improves Tibial Component Alignment: A Pilot Study

Auteurs : Jess H. Lonner ; Thomas K. John ; Michael A. Conditt

Source :

RBID : PMC:2795844

Abstract

The alignment of the components of unicompartmental knee arthroplasty (UKA) reportedly influences outcomes and durability. A novel robotic arm technology has been developed with the expectation that it could improve the accuracy of bone preparation in UKA. During the study period, we compared the postoperative radiographic alignment of the tibial component with the preoperatively planned position in 31 knees in 31 consecutive patients undergoing UKA using robotic arm-assisted bone preparation and in 27 consecutive patients who underwent unilateral UKA using conventional manual instrumentation to determine the error of bone preparation and variance with each technique. Radiographically, the root mean square error of the posterior tibial slope was 3.1° when using manual techniques compared with 1.9° when using robotic arm assistance for bone preparation. In addition, the variance using manual instruments was 2.6 times greater than the robotically guided procedures. In the coronal plane, the average error was 2.7° ± 2.1° more varus of the tibial component relative to the mechanical axis of the tibia using manual instruments compared with 0.2° ± 1.8° with robotic technology, and the varus/valgus root mean square error was 3.4° manually compared with 1.8° robotically. Further study will be necessary to determine whether a reduction in alignment errors of these magnitudes will ultimately influence implant function or survival.

Level of Evidence: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Url:
DOI: 10.1007/s11999-009-0977-5
PubMed: 19593669
PubMed Central: 2795844

Links to Exploration step

PMC:2795844***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000702 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000702 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:2795844
   |texte=   Robotic Arm-assisted UKA Improves Tibial Component Alignment: A Pilot Study
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:19593669" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024