Comparison Between Digital and Manual Marking for Toric Intraocular Lenses

Identifieur interne : 000254 ( Pmc/Corpus ); précédent : 000253; suivant : 000255

Comparison Between Digital and Manual Marking for Toric Intraocular Lenses

Auteurs : Abdel Hamid Elhofi ; Hany Ahmed Helaly

Source :

RBID : PMC:4635770

Abstract

Abstract

To compare the clinical outcome of digital and manual marking for toric intraocular lens (IOL) alignment.

This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). The eyes were randomly assigned to either digital image guidance using VERION digital marker (Alcon Laboratories, Ft. Worth, TX) or manual slitlamp-assisted preoperative marking using pendulum-attached marker. Tecnis toric IOL (Abbott Medical Optics, Inc, Santa Ana, CA) was implanted in all cases.

The mean postoperative uncorrected distance visual acuity (UCDVA) for the digital-marking group was 0.12 + 0.12 logMAR, and for the manual-marking group was 0.18 + 0.14 logMAR (P = 0.104). The mean deviation from targeted induced astigmatism (TIA) for the first group was 0.10 + 0.08 D and for the second group was 0.20 + 0.14 D (P = 0.001). The mean postoperative toric IOL misalignment measured by the slitlamp was 2.4° + 1.96° for the first group and was 4.33° + 2.72° for the second group (P = 0.003).

Accurate alignment of the toric IOL is important to achieve the desired astigmatism correction. VERION system has the advantage of preoperative planning and intraoperative digital guidance of the toric IOL alignment. The use of VERION system resulted in less postoperative deviation from TIA and showed less postoperative toric IOL misalignment than using manual-marking technique.


Url:
DOI: 10.1097/MD.0000000000001618
PubMed: 26402830
PubMed Central: 4635770

Links to Exploration step

PMC:4635770***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000254 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000254 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4635770
   |texte=   Comparison Between Digital and Manual Marking for Toric Intraocular Lenses
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:26402830" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024