New Dacron tissue colonisable keratoprosthesis: clinical experience.

Identifieur interne : 002705 ( Pmc/Checkpoint ); précédent : 002704; suivant : 002706

New Dacron tissue colonisable keratoprosthesis: clinical experience.

Auteurs : S. Pintucci ; F. Pintucci ; M. Cecconi ; S. Caiazza

Source :

RBID : PMC:505268

Abstract

BACKGROUND--Keratoprostheses (KPs) are made of an optical cylinder integrated with a supporting element which conditions their biocompatibility. A new KP with a Dacron tissue colonisable support has been designed in order to reduce significantly the complication rate. METHODS--This new KP was implanted into 20 eyes of 20 patients with bilateral corneal blindness unsuited to a corneal implant. The follow up ranged from 24 to 96 months. RESULTS--All 20 patients had some improved visual acuity with 13 retaining this improvement for more than 2 years. CONCLUSION--These favourable results may be indicative of the reliability of the new KP.

Images

Url:
PubMed: 7488601
PubMed Central: 505268


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:505268

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">New Dacron tissue colonisable keratoprosthesis: clinical experience.</title>
<author>
<name sortKey="Pintucci, S" sort="Pintucci, S" uniqKey="Pintucci S" first="S" last="Pintucci">S. Pintucci</name>
</author>
<author>
<name sortKey="Pintucci, F" sort="Pintucci, F" uniqKey="Pintucci F" first="F" last="Pintucci">F. Pintucci</name>
</author>
<author>
<name sortKey="Cecconi, M" sort="Cecconi, M" uniqKey="Cecconi M" first="M" last="Cecconi">M. Cecconi</name>
</author>
<author>
<name sortKey="Caiazza, S" sort="Caiazza, S" uniqKey="Caiazza S" first="S" last="Caiazza">S. Caiazza</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">7488601</idno>
<idno type="pmc">505268</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC505268</idno>
<idno type="RBID">PMC:505268</idno>
<date when="1995">1995</date>
<idno type="wicri:Area/Pmc/Corpus">000A36</idno>
<idno type="wicri:Area/Pmc/Curation">000A36</idno>
<idno type="wicri:Area/Pmc/Checkpoint">002705</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">New Dacron tissue colonisable keratoprosthesis: clinical experience.</title>
<author>
<name sortKey="Pintucci, S" sort="Pintucci, S" uniqKey="Pintucci S" first="S" last="Pintucci">S. Pintucci</name>
</author>
<author>
<name sortKey="Pintucci, F" sort="Pintucci, F" uniqKey="Pintucci F" first="F" last="Pintucci">F. Pintucci</name>
</author>
<author>
<name sortKey="Cecconi, M" sort="Cecconi, M" uniqKey="Cecconi M" first="M" last="Cecconi">M. Cecconi</name>
</author>
<author>
<name sortKey="Caiazza, S" sort="Caiazza, S" uniqKey="Caiazza S" first="S" last="Caiazza">S. Caiazza</name>
</author>
</analytic>
<series>
<title level="j">The British Journal of Ophthalmology</title>
<idno type="ISSN">0007-1161</idno>
<idno type="eISSN">1468-2079</idno>
<imprint>
<date when="1995">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>BACKGROUND--Keratoprostheses (KPs) are made of an optical cylinder integrated with a supporting element which conditions their biocompatibility. A new KP with a Dacron tissue colonisable support has been designed in order to reduce significantly the complication rate. METHODS--This new KP was implanted into 20 eyes of 20 patients with bilateral corneal blindness unsuited to a corneal implant. The follow up ranged from 24 to 96 months. RESULTS--All 20 patients had some improved visual acuity with 13 retaining this improvement for more than 2 years. CONCLUSION--These favourable results may be indicative of the reliability of the new KP.</p>
<sec sec-type="scanned-figures">
<title>Images</title>
<fig id="F1">
<graphic xlink:href="brjopthal00021-0035-a" xlink:role="825"></graphic>
</fig>
<fig id="F2">
<graphic xlink:href="brjopthal00021-0036-a" xlink:role="826"></graphic>
</fig>
<fig id="F3">
<graphic xlink:href="brjopthal00021-0036-b" xlink:role="826"></graphic>
</fig>
</sec>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Br J Ophthalmol</journal-id>
<journal-title>The British Journal of Ophthalmology</journal-title>
<issn pub-type="ppub">0007-1161</issn>
<issn pub-type="epub">1468-2079</issn>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">7488601</article-id>
<article-id pub-id-type="pmc">505268</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Research Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>New Dacron tissue colonisable keratoprosthesis: clinical experience.</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Pintucci</surname>
<given-names>S</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Pintucci</surname>
<given-names>F</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Cecconi</surname>
<given-names>M</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Caiazza</surname>
<given-names>S</given-names>
</name>
</contrib>
</contrib-group>
<aff>Department of Ophthalmology, S Giovanni Hospital, Rome, Italy.</aff>
<pub-date pub-type="ppub">
<month>9</month>
<year>1995</year>
</pub-date>
<volume>79</volume>
<issue>9</issue>
<fpage>825</fpage>
<lpage>829</lpage>
<abstract>
<p>BACKGROUND--Keratoprostheses (KPs) are made of an optical cylinder integrated with a supporting element which conditions their biocompatibility. A new KP with a Dacron tissue colonisable support has been designed in order to reduce significantly the complication rate. METHODS--This new KP was implanted into 20 eyes of 20 patients with bilateral corneal blindness unsuited to a corneal implant. The follow up ranged from 24 to 96 months. RESULTS--All 20 patients had some improved visual acuity with 13 retaining this improvement for more than 2 years. CONCLUSION--These favourable results may be indicative of the reliability of the new KP.</p>
<sec sec-type="scanned-figures">
<title>Images</title>
<fig id="F1">
<graphic xlink:href="brjopthal00021-0035-a" xlink:role="825"></graphic>
</fig>
<fig id="F2">
<graphic xlink:href="brjopthal00021-0036-a" xlink:role="826"></graphic>
</fig>
<fig id="F3">
<graphic xlink:href="brjopthal00021-0036-b" xlink:role="826"></graphic>
</fig>
</sec>
</abstract>
</article-meta>
</front>
</pmc>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Caiazza, S" sort="Caiazza, S" uniqKey="Caiazza S" first="S" last="Caiazza">S. Caiazza</name>
<name sortKey="Cecconi, M" sort="Cecconi, M" uniqKey="Cecconi M" first="M" last="Cecconi">M. Cecconi</name>
<name sortKey="Pintucci, F" sort="Pintucci, F" uniqKey="Pintucci F" first="F" last="Pintucci">F. Pintucci</name>
<name sortKey="Pintucci, S" sort="Pintucci, S" uniqKey="Pintucci S" first="S" last="Pintucci">S. Pintucci</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002705 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd -nk 002705 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Checkpoint
   |type=    RBID
   |clé=     PMC:505268
   |texte=   New Dacron tissue colonisable keratoprosthesis: clinical experience.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/RBID.i   -Sk "pubmed:7488601" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024