Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Psychophysical Detection of Inclusions with the Bare Finger amidst Softness Differentials

Identifieur interne : 001D84 ( Pmc/Checkpoint ); précédent : 001D83; suivant : 001D85

Psychophysical Detection of Inclusions with the Bare Finger amidst Softness Differentials

Auteurs : Leigh A. Baumgart ; Gregory J. Gerling ; Ellen J. Bass

Source :

RBID : PMC:2995217

Abstract

Softness discrimination and the detection of inclusions are important in surgery and other medical tasks. To better understand how the characteristics of an inclusion (size, depth, hardness) and substrate (stiffness) affect their tactile detection and discrimination with the bare finger, we conducted a psychophysics experiment with eighteen participants. The results indicate that within a more pliant substrate (21 kPa), inclusions of 4 mm diameter (20 mm3 volume) and greater were consistently detectable (above 75% of the time) but only at a depth of 5 mm. Inclusions embedded in stiffer substrates (82 kPa) had to be twice that volume (5 mm diameter, 40 mm3 volume) to be detectable at the same rate. To analyze which tactile cues most impact stimulus detectability, we utilized logistic regression and generalized estimating equations. The results indicate that substrate stiffness most contributes to inclusion detectability, while the size, depth, and hardness of the stimulus follow in individual importance, respectively. The results seek to aid in the development of clinical tools and information displays and more accurate virtual haptic environments in discrimination of soft tissue.


Url:
DOI: 10.1109/HAPTIC.2010.5444684
PubMed: 21132051
PubMed Central: 2995217


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:2995217

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Psychophysical Detection of Inclusions with the Bare Finger amidst Softness Differentials</title>
<author>
<name sortKey="Baumgart, Leigh A" sort="Baumgart, Leigh A" uniqKey="Baumgart L" first="Leigh A." last="Baumgart">Leigh A. Baumgart</name>
</author>
<author>
<name sortKey="Gerling, Gregory J" sort="Gerling, Gregory J" uniqKey="Gerling G" first="Gregory J." last="Gerling">Gregory J. Gerling</name>
</author>
<author>
<name sortKey="Bass, Ellen J" sort="Bass, Ellen J" uniqKey="Bass E" first="Ellen J." last="Bass">Ellen J. Bass</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">21132051</idno>
<idno type="pmc">2995217</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2995217</idno>
<idno type="RBID">PMC:2995217</idno>
<idno type="doi">10.1109/HAPTIC.2010.5444684</idno>
<date when="2010">2010</date>
<idno type="wicri:Area/Pmc/Corpus">000F59</idno>
<idno type="wicri:Area/Pmc/Curation">000F59</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001D84</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Psychophysical Detection of Inclusions with the Bare Finger amidst Softness Differentials</title>
<author>
<name sortKey="Baumgart, Leigh A" sort="Baumgart, Leigh A" uniqKey="Baumgart L" first="Leigh A." last="Baumgart">Leigh A. Baumgart</name>
</author>
<author>
<name sortKey="Gerling, Gregory J" sort="Gerling, Gregory J" uniqKey="Gerling G" first="Gregory J." last="Gerling">Gregory J. Gerling</name>
</author>
<author>
<name sortKey="Bass, Ellen J" sort="Bass, Ellen J" uniqKey="Bass E" first="Ellen J." last="Bass">Ellen J. Bass</name>
</author>
</analytic>
<series>
<title level="j">Proceedings / Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems</title>
<idno type="ISSN">1551-5435</idno>
<imprint>
<date when="2010">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p id="P1">Softness discrimination and the detection of inclusions are important in surgery and other medical tasks. To better understand how the characteristics of an inclusion (size, depth, hardness) and substrate (stiffness) affect their tactile detection and discrimination with the bare finger, we conducted a psychophysics experiment with eighteen participants. The results indicate that within a more pliant substrate (21 kPa), inclusions of 4 mm diameter (20 mm
<sup>3</sup>
volume) and greater were consistently detectable (above 75% of the time) but only at a depth of 5 mm. Inclusions embedded in stiffer substrates (82 kPa) had to be twice that volume (5 mm diameter, 40 mm
<sup>3</sup>
volume) to be detectable at the same rate. To analyze which tactile cues most impact stimulus detectability, we utilized logistic regression and generalized estimating equations. The results indicate that substrate stiffness most contributes to inclusion detectability, while the size, depth, and hardness of the stimulus follow in individual importance, respectively. The results seek to aid in the development of clinical tools and information displays and more accurate virtual haptic environments in discrimination of soft tissue.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article" xml:lang="EN">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<pmc-dir>properties manuscript</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-journal-id">101536400</journal-id>
<journal-id journal-id-type="pubmed-jr-id">38271</journal-id>
<journal-id journal-id-type="nlm-ta">Proc Symp Haptic Interface Virtual Env Teleoperator Syst</journal-id>
<journal-title>Proceedings / Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems</journal-title>
<issn pub-type="ppub">1551-5435</issn>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">21132051</article-id>
<article-id pub-id-type="pmc">2995217</article-id>
<article-id pub-id-type="doi">10.1109/HAPTIC.2010.5444684</article-id>
<article-id pub-id-type="manuscript">NIHMS208378</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Psychophysical Detection of Inclusions with the Bare Finger amidst Softness Differentials</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Baumgart</surname>
<given-names>Leigh A.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gerling</surname>
<given-names>Gregory J.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Bass</surname>
<given-names>Ellen J.</given-names>
</name>
</contrib>
<aff id="A1">Department of Systems and Information Engineering, University of Virginia, USA</aff>
</contrib-group>
<author-notes>
<corresp id="FN1">Gregory J. Gerling, Ph.D., The University of Virginia, Department of Systems and Information Engineering, 151 Engineer’s Way, P.O. Box 400747, Charlottesville, VA 22904,
<email>gg7h@virginia.edu</email>
</corresp>
</author-notes>
<pub-date pub-type="nihms-submitted">
<day>22</day>
<month>11</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="ppub">
<day>10</day>
<month>4</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="pmc-release">
<day>1</day>
<month>12</month>
<year>2010</year>
</pub-date>
<volume>2010</volume>
<fpage>17</fpage>
<lpage>20</lpage>
<abstract>
<p id="P1">Softness discrimination and the detection of inclusions are important in surgery and other medical tasks. To better understand how the characteristics of an inclusion (size, depth, hardness) and substrate (stiffness) affect their tactile detection and discrimination with the bare finger, we conducted a psychophysics experiment with eighteen participants. The results indicate that within a more pliant substrate (21 kPa), inclusions of 4 mm diameter (20 mm
<sup>3</sup>
volume) and greater were consistently detectable (above 75% of the time) but only at a depth of 5 mm. Inclusions embedded in stiffer substrates (82 kPa) had to be twice that volume (5 mm diameter, 40 mm
<sup>3</sup>
volume) to be detectable at the same rate. To analyze which tactile cues most impact stimulus detectability, we utilized logistic regression and generalized estimating equations. The results indicate that substrate stiffness most contributes to inclusion detectability, while the size, depth, and hardness of the stimulus follow in individual importance, respectively. The results seek to aid in the development of clinical tools and information displays and more accurate virtual haptic environments in discrimination of soft tissue.</p>
</abstract>
<kwd-group>
<kwd>Softness discrimination</kwd>
<kwd>inclusion detection</kwd>
<kwd>psychophysics</kwd>
<kwd>tactile perception</kwd>
<kwd>medical simulation</kwd>
</kwd-group>
<contract-num rid="LM1">T15 LM009462-03 ||LM</contract-num>
<contract-num rid="LM1">T15 LM009462-02 ||LM</contract-num>
<contract-num rid="LM1">T15 LM009462-01 ||LM</contract-num>
<contract-sponsor id="LM1">National Library of Medicine : NLM</contract-sponsor>
</article-meta>
</front>
</pmc>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Bass, Ellen J" sort="Bass, Ellen J" uniqKey="Bass E" first="Ellen J." last="Bass">Ellen J. Bass</name>
<name sortKey="Baumgart, Leigh A" sort="Baumgart, Leigh A" uniqKey="Baumgart L" first="Leigh A." last="Baumgart">Leigh A. Baumgart</name>
<name sortKey="Gerling, Gregory J" sort="Gerling, Gregory J" uniqKey="Gerling G" first="Gregory J." last="Gerling">Gregory J. Gerling</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001D84 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd -nk 001D84 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Checkpoint
   |type=    RBID
   |clé=     PMC:2995217
   |texte=   Psychophysical Detection of Inclusions with the Bare Finger amidst Softness Differentials
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/RBID.i   -Sk "pubmed:21132051" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024